Pith. sign in

REVIEW

Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1612.04185 v1 pith:HGVMWLH5 submitted 2016-11-22 physics.med-ph physics.data-anstat.AP

Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands

classification physics.med-ph physics.data-anstat.AP
keywords apneasleepsignalsfeatureswereeventsmachinepiezo-electric
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Physiologically, the thoracic (THO) and abdominal (ABD) movement signals, captured using wearable piezo-electric bands, provide information about various types of apnea, including central sleep apnea (CSA) and obstructive sleep apnea (OSA). However, the use of piezo-electric wearables in detecting sleep apnea events has been seldom explored in the literature. This study explored the possibility of identifying sleep apnea events, including OSA and CSA, by solely analyzing {one or both the THO and ABD signals. An adaptive non-harmonic model was introduced to model the THO and ABD signals, which allows us to design features for sleep apnea events. To confirm the suitability of the extracted features, a support vector machine was applied to classify three categories -- normal and hypopnea, OSA, and CSA. According to a database of} 34 subjects, the overall classification accuracies were on average $75.9\%\pm 11.7\%$ and $73.8\%\pm 4.4\%$, respectively, based on the cross validation. When the features determined from the THO and ABD signals were combined, the overall classification accuracy became $81.8\%\pm 9.4\%$. These features were applied for designing a state machine for online apnea event detection. Two event-by-event accuracy indices, S and I, were proposed for evaluating the performance {of the state machine. For the same database, the} S index was $84.01\%\pm 9.06\%$, and the I index was $77.21\%\pm 19.01\%$. The results indicate the considerable potential of applying the proposed algorithm to clinical examinations for both screening and homecare purposes.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.