Pith. sign in

REVIEW

Fundamental limits to frequency estimation: A comprehensive microscopic perspective

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1710.04673 v2 pith:DOE6ZEOX submitted 2017-10-12 quant-ph

Fundamental limits to frequency estimation: A comprehensive microscopic perspective

classification quant-ph
keywords dynamicsprecisionprobesbathsfrequencymicroscopicnoisephase-covariance
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We consider a scenario in which qubit-like probes are used to sense an external field that linearly affects their energy splitting. Following the frequency estimation approach in which one optimizes the state and sensing time of the probes to maximize the sensitivity, we provide a systematic study of the attainable precision under the impact of noise originating from independent bosonic baths. We invoke an explicit microscopic derivation of the probe dynamics using the spin-boson model with weak coupling of arbitrary geometry and clarify how the secular approximation leads to a phase-covariant dynamics, where the noise terms commute with the field Hamiltonian, while the inclusion of non-secular terms breaks the phase-covariance. Moreover, unless one restricts to a particular (i.e., Ohmic) spectral density of the bath modes, the noise terms may contain relevant information about the frequency to be estimated. Thus, by considering general evolutions of a single probe, we study regimes in which these two effects have a non-negligible impact on the achievable precision. We then consider baths of Ohmic spectral density yet fully accounting for the lack of phase-covariance, in order to characterize the ultimate attainable scaling of precision when $N$ probes are used in parallel. Crucially, we show that beyond the semigroup (Lindbladian) regime the Zeno limit imposing the $1/N^{3/2}$ scaling of the mean squared error, derived assuming phase-covariance, generalises to any dynamics of the probes, unless the latter are coupled to the baths in the direction perfectly transversal to the encoding---when a novel scaling of $1/N^{7/4}$ arises. As our microscopic approach covers all classes of dissipative dynamics, from semigroup to non-Markovian ones (potentially non-phase-covariant), it provides an exhaustive picture, in which all the different asymptotic scalings of precision naturally emerge.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.