RECORD
Is the Cometary Nucleus Extraction Technique Reliable?
Earth and Planetary Astrophysics · Submitted 20 Jul 2018
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim Our experiment reveals that, given an optically thin coma, generally, the smaller the signal ratio of nucleus to coma, the less reliable is the cometary nucleus-extraction technique.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
It depends. Our experiment reveals that, given an optically thin coma, generally, the smaller the signal ratio of nucleus to coma, the less reliable is the cometary nucleus-extraction technique. We strongly suggest the technique only be applied to cases where the nucleus signal occupies $\gtrsim$10% of the total signal wherein the bias is no more than a few percent. Otherwise there is probably no way to debias results from this technique in reality, since its reliability is highly sensitive to entangling complications, including the coma profile, and the point-spread function (PSF).
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | It depends. | interpretation 0.50 | 0.05 | 0.08 | unclear 0.70 |
| s1 | Our experiment reveals that, given an optically thin coma, generally, the smaller the signal ratio of nucleus to coma, the less reliable is the cometary nucleus-extraction technique. | result 0.99 | 0.95 | 0.55 | asserted 0.99 |
| s2 | We strongly suggest the technique only be applied to cases where the nucleus signal occupies $\gtrsim$10% of the total signal wherein the bias is no more than a few percent. | interpretation 0.39 | 0.77 | 0.63 | hedged possibility 0.78 |
| s3 | Otherwise there is probably no way to debias results from this technique in reality, since its reliability is highly sensitive to entangling complications, including the coma profile, and the point-spread function (PSF). | limitation 0.60 | 0.46 | 0.23 | hedged possibility 0.90 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
It depends. Our experiment reveals that, given an optically thin coma, generally, the smaller the signal ratio of nucleus to coma, the less reliable is the cometary nucleus-extraction technique. We strongly suggest the technique only be applied to cases where the nucleus signal occupies $\gtrsim$10% of the total signal wherein the bias is no more than a few percent. Otherwise there is probably no way to debias results from this technique in reality, since its reliability is highly sensitive to entangling complications, including the coma profile, and the point-spread function (PSF).
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.