Pith. sign in

REVIEW 1 cited by

Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1906.00054 v3 pith:KZRTWHKH submitted 2019-05-31 physics.ins-det astro-ph.IM

Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment

classification physics.ins-det astro-ph.IM
keywords detectorsgapsparticlex-raydetectorenergyfirstresolution
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

    astro-ph.IM 2026-04 unverdicted novelty 5.0

    GAPS has constructed and launched a stratospheric balloon spectrometer that uses silicon trackers and TOF detectors to identify low-energy antiprotons, antideuterons, and antihelium via exotic-atom formation and annih...