Pith. sign in

REVIEW 1 cited by

Zeeman-tunable Modulation Transfer Spectroscopy

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1906.04154 v4 pith:MSAPFBOW submitted 2019-06-07 physics.atom-ph physics.ins-detphysics.opticsquant-ph

classification physics.atom-phphysics.ins-detphysics.opticsquant-ph
keywords modulationtransferlockingtransitioncoolingerrorlaserrightarrow
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Active frequency stabilization of a laser to an atomic or molecular resonance underpins many modern-day AMO physics experiments. With a flat background and high signal-to-noise ratio, modulation transfer spectroscopy (MTS) offers an accurate and stable method for laser locking. Despite its benefits, however, the four-wave mixing process that is inherent to the MTS technique entails that the strongest modulation transfer signals are only observed for closed transitions, excluding MTS from numerous applications. Here, we report for the first time the observation of a magnetically tunable MTS error signal. Using a simple two-magnet arrangement, we show that the error signal for the $^{87}$Rb $F=2 \rightarrow F'=3$ cooling transition can be Zeeman-shifted over a range of $>$15 GHz to any arbitrary point on the rubidium $\text{D}_2$ spectrum. Modulation transfer signals for locking to the $^{87}$Rb $F=1 \rightarrow F'=2$ repumping transition as well as 1 GHz red-detuned to the cooling transition are presented to demonstrate the versatility of this technique, which can readily be extended to the locking of Raman and lattice lasers.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Measuring the Faraday effect in olive oil using permanent magnets and Malus' law

    physics.ins-det 2019-08 conditional novelty 5.0 of 10

    The authors measure the Faraday rotation in olive oil with permanent magnets and full Malus-law fitting, obtaining V = 192 ± 1 deg T^-1 m^-1 at 659.2 nm and confirming that earlier reports of an anomalously large effe...