Pith. Sign in

RECORD

Top quark mass measurement in radiative events at electron-positron colliders

High Energy Physics - Phenomenology · Submitted 3 Dec 2019

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim With this method, the top quark mass can be determined with a precision of $110$ MeV in the initial stage of CLIC, with $1$ ab$^{-1}$ at $\sqrt{s} =$ 380 GeV, and with a precision of approximately $150$ MeV at the ILC, with $L = 4$ ab$^{-1}$ at $\sqrt{s}= 500$ GeV.

how it is stated · asserted 0.76 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID1912.01275 (version 1)
Pith IDCUV3WNSH, Pith's permanent record of this paper and its review
CitationAndr\'e Hoang, Angelika Widl, Esteban Fullana, Juan Fuster, Mar\c{c}a Boronat, Marcel Vos, Pablo Gomis, Vicent Mateu. "Top quark mass measurement in radiative events at electron-positron colliders." arXiv:1912.01275 (2019). https://pith.science/paper/CUV3WNSH
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,335 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.20 · human participants 0.01 · controlled comparison 0.03 · randomized assignment 0.01 · states quantitative result 0.98 · compares with prior results 0.11 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

In this letter, we evaluate potential of linear $e^+e^-$ colliders to measure the top quark mass in radiative events and in a suitable short-distance scheme. We present a calculation of the differential cross section for production of a top quark pair in association with an energetic photon from initial state radiation, as a function of the invariant mass of the $t\bar{t}$ system. This {\it matched} calculation includes the QCD enhancement of the cross section around the $t\bar{t}$ production threshold and remains valid in the continuum well above the threshold. The uncertainty in the top mass determination is evaluated in realistic operating scenarios for the Compact Linear Collider (CLIC) and the International Linear Collider (ILC), including the statistical uncertainty and the theoretical and experimental systematic uncertainties. With this method, the top quark mass can be determined with a precision of $110$ MeV in the initial stage of CLIC, with $1$ ab$^{-1}$ at $\sqrt{s} =$ 380 GeV, and with a precision of approximately $150$ MeV at the ILC, with $L = 4$ ab$^{-1}$ at $\sqrt{s}= 500$ GeV. Radiative events allow measurements of the top quark mass at different renormalization scales, and we demonstrate that such a measurement can yield a statistically significant test of the evolution of the MSR mass $m_t^{\rm MSR}(R)$ for scales $R< m_t$.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 In this letter, we evaluate potential of linear $e^+e^-$ colliders to measure the top quark mass in radiative events and in a suitable short-distance scheme. contribution 0.96 0.80 0.08 hedged possibility 0.53
s1 We present a calculation of the differential cross section for production of a top quark pair in association with an energetic photon from initial state radiation, as a function of the invariant mass of the $t\bar{t}$ system. contribution 0.72 0.95 0.04 asserted 0.99
s2 This {\it matched} calculation includes the QCD enhancement of the cross section around the $t\bar{t}$ production threshold and remains valid in the continuum well above the threshold. method 0.79 0.89 0.05 asserted 1.00
s3 The uncertainty in the top mass determination is evaluated in realistic operating scenarios for the Compact Linear Collider (CLIC) and the International Linear Collider (ILC), including the statistical uncertainty and the theoretical and experimental systematic uncertainties. method 0.66 0.88 0.08 asserted 0.98
s4 With this method, the top quark mass can be determined with a precision of $110$ MeV in the initial stage of CLIC, with $1$ ab$^{-1}$ at $\sqrt{s} =$ 380 GeV, and with a precision of approximately $150$ MeV at the ILC, with $L = 4$ ab$^{-1}$ at $\sqrt{s}= 500$ GeV. result 1.00 0.87 0.64 asserted 0.76
s5 Radiative events allow measurements of the top quark mass at different renormalization scales, and we demonstrate that such a measurement can yield a statistically significant test of the evolution of the MSR mass $m_t^{\rm MSR}(R)$ for scales $R< m_t$. result 0.39 0.90 0.18 asserted 0.97

What kind of paper the classifier reports this is: theoretical result 0.66 · evidence from simulation or computation 0.69.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

In this letter, we evaluate potential of linear $e^+e^-$ colliders to measure the top quark mass in radiative events and in a suitable short-distance scheme. We present a calculation of the differential cross section for production of a top quark pair in association with an energetic photon from initial state radiation, as a function of the invariant mass of the $t\bar{t}$ system. This {\it matched} calculation includes the QCD enhancement of the cross section around the $t\bar{t}$ production threshold and remains valid in the continuum well above the threshold. The uncertainty in the top mass determination is evaluated in realistic operating scenarios for the Compact Linear Collider (CLIC) and the International Linear Collider (ILC), including the statistical uncertainty and the theoretical and experimental systematic uncertainties. With this method, the top quark mass can be determined with a precision of $110$ MeV in the initial stage of CLIC, with $1$ ab$^{-1}$ at $\sqrt{s} =$ 380 GeV, and with a precision of approximately $150$ MeV at the ILC, with $L = 4$ ab$^{-1}$ at $\sqrt{s}= 500$ GeV. Radiative events allow measurements of the top quark mass at different renormalization scales, and we demonstrate that such a measurement can yield a statistically significant test of the evolution of the MSR mass $m_t^{\rm MSR}(R)$ for scales $R< m_t$.

Human review
How the literature uses it

5 arXiv papers cite this in 9 sentences

Each citing sentence is taken from the citing paper's LaTeX source and typed by Pith's classifier. A label appears at probability 0.8 or more (0.95 for support), a contest at 0.7 or more; the quoted words are the citing authors'. How each label was checked · JSON

Papers citing it · 7 sentences without a confident label

Uses its data or values 1 paper
Cites it as background 1 paper

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.