Pith. sign in

REVIEW 1 cited by

Self-Supervised CSF Inpainting with Synthetic Atrophy for Improved Accuracy Validation of Cortical Surface Analyses

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2303.05777 v1 pith:M4GBRWVY submitted 2023-03-10 eess.IV cs.CVcs.LG

classification eess.IVcs.CVcs.LG
keywords corticalaccuracyatrophyimagesmethodsthicknessvalidationdata
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Accuracy validation of cortical thickness measurement is a difficult problem due to the lack of ground truth data. To address this need, many methods have been developed to synthetically induce gray matter (GM) atrophy in an MRI via deformable registration, creating a set of images with known changes in cortical thickness. However, these methods often cause blurring in atrophied regions, and cannot simulate realistic atrophy within deep sulci where cerebrospinal fluid (CSF) is obscured or absent. In this paper, we present a solution using a self-supervised inpainting model to generate CSF in these regions and create images with more plausible GM/CSF boundaries. Specifically, we introduce a novel, 3D GAN model that incorporates patch-based dropout training, edge map priors, and sinusoidal positional encoding, all of which are established methods previously limited to 2D domains. We show that our framework significantly improves the quality of the resulting synthetic images and is adaptable to unseen data with fine-tuning. We also demonstrate that our resulting dataset can be employed for accuracy validation of cortical segmentation and thickness measurement.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. VAMOS-OCTA: Vessel-Aware Multi-Axis Orthogonal Supervision for Inpainting Motion-Corrupted OCT Angiography Volumes

    cs.CV 2026-02 conditional novelty 6.0 of 10

    VAMOS-OCTA adds axial and lateral MIP/AIP projection losses to vessel-weighted MSE training, improving motion-corrupted B-scan inpainting in handheld OCTA.

Pith tools