Pith. sign in

REVIEW 1 cited by

iMove: Exploring Bio-impedance Sensing for Fitness Activity Recognition

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2402.09445 v2 pith:HCSHGR4W submitted 2024-01-31 eess.SP cs.AIcs.LGcs.RO

classification eess.SPcs.AIcs.LGcs.RO
keywords fitnessbio-impedanceactivityrecognitionaveragecontrastivefusionlearning
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Automatic and precise fitness activity recognition can be beneficial in aspects from promoting a healthy lifestyle to personalized preventative healthcare. While IMUs are currently the prominent fitness tracking modality, through iMove, we show bio-impedence can help improve IMU-based fitness tracking through sensor fusion and contrastive learning.To evaluate our methods, we conducted an experiment including six upper body fitness activities performed by ten subjects over five days to collect synchronized data from bio-impedance across two wrists and IMU on the left wrist.The contrastive learning framework uses the two modalities to train a better IMU-only classification model, where bio-impedance is only required at the training phase, by which the average Macro F1 score with the input of a single IMU was improved by 3.22 \% reaching 84.71 \% compared to the 81.49 \% of the IMU baseline model. We have also shown how bio-impedance can improve human activity recognition (HAR) directly through sensor fusion, reaching an average Macro F1 score of 89.57 \% (two modalities required for both training and inference) even if Bio-impedance alone has an average macro F1 score of 75.36 \%, which is outperformed by IMU alone. In addition, similar results were obtained in an extended study on lower body fitness activity classification, demonstrating the generalisability of our approach.Our findings underscore the potential of sensor fusion and contrastive learning as valuable tools for advancing fitness activity recognition, with bio-impedance playing a pivotal role in augmenting the capabilities of IMU-based systems.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. SImpHAR: Advancing impedance-based human activity recognition using 3D simulation and text-to-motion models

    cs.CV 2025-07 conditional novelty 6.0 of 10

    SImpHAR simulates bio-impedance signals from 3D motion and text, then uses contrastive pretraining and fine-tuning to improve impedance-based human activity recognition on two of three datasets.

Pith tools