Pith. sign in

REVIEW

Effect of annealing on the hot salt corrosion resistance of the fine-grained titanium alpha-alloy Ti-2.5Al-2.6Zr obtained via cold Rotary Swaging

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.13587 v1 pith:2U2MFQEU submitted 2024-03-20 physics.app-ph cond-mat.mtrl-sci

Effect of annealing on the hot salt corrosion resistance of the fine-grained titanium alpha-alloy Ti-2.5Al-2.6Zr obtained via cold Rotary Swaging

classification physics.app-ph cond-mat.mtrl-sci
keywords annealingcorrosionalpha-alloytitaniumal-2ti-2werealloy
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

A hot salt corrosion (HSC) test was performed on the fine-grained titanium alpha-alloy Ti-2.5Al-2.6Zr (Russian industrial alloy PT-7M). The ultrafine-grained (UFG) microstructure in the titanium alpha-alloy was formed via cold Rotary Swaging. The grain size and volume fraction of the recrystallized microstructure in the alloy were varied by choosing appropriate annealing temperatures and times. The microstructure and corrosion resistance of UFG alloys were studied after 30 min of annealing at 500-700C and after 1000 h of annealing at 250C. Metallographic studies were carried out to investigate the effects of annealing on the nature and extent of corrosive damage in the titanium alpha-alloy Ti-2.5Al-2.6Zr. After HSC tests, surface analyses of the titanium alpha-alloy samples were conducted using X-ray diffraction and electron microscopy. During the HSC testing of the titanium alpha-alloy Ti-2.5Al-2.6Zr, a competitive interaction between intergranular corrosion (IGC) and pitting corrosion was observed. To the best of our knowledge, it was shown for the first time that annealing affects the relationship among the IGC, pitting corrosion and uniform corrosion rates of the titanium alloy. Prolonged low-temperature annealing at 250C resulted in a more pronounced increase in the uniform corrosion rate than short-term high-temperature annealing for 30 min at 500-700C. An in-depth analysis of the effect of the structure and phase composition of the grain boundaries on the susceptibility of the alpha-alloy Ti-2.5Al-2.6Zr to HSC was conducted.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.