Pith. sign in

REVIEW 1 cited by

CONCERTO at APEX -- On-sky performance in continuum

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2406.15572 v1 pith:B6XJ3AX7 submitted 2024-06-21 astro-ph.IM astro-ph.COastro-ph.GA

CONCERTO at APEX -- On-sky performance in continuum

classification astro-ph.IM astro-ph.COastro-ph.GA
keywords concertobeamcontinuumfieldlekidsperformancebandscalibration
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

We present the data-processing algorithms and the performance of CONCERTO (CarbON CII line in post-rEionisation and ReionisaTiOn epoch) in continuum by analysing the data from the commissioning and scientific observations. The beam pattern is characterized by an effective FWHM of 31.9 $\pm$ 0.6" and 34.4 $\pm$ 1.0" for high-frequency (HF) and low-frequency (LF) bands. The main beam is slightly elongated with a mean eccentricity of 0.46. Two error beams of $\sim$65" and $\sim$130" are characterized, enabling the estimate of a main beam efficiency of $\sim$0.52. The field of view is accurately reconstructed and presents coherent distortions between the HF and LF arrays. LEKID parameters were robustly determined for 80% of the read tones. Cross-talks between LEKIDs are the first cause of flagging, followed by an excess of eccentricity for $\sim$10% of the LEKIDs, all located in a given region of the field of view. On the 44 scans of Uranus selected for the absolute photometric calibration, 72.5% and 78.2% of the LEKIDs are selected as valid detectors with a probability >70%. By comparing Uranus measurements with a model, we obtain calibration factors of 19.5$\pm$0.6 [Hz/Jy] and 25.6$\pm$0.9 [Hz/Jy] for HF and LF. The point-source continuum measurement uncertainties are 3.0% and 3.4% for HF and LF bands. The RMS of CONCERTO maps is verified to evolve as proportional to the inverse square root of integration time. The measured NEFDs for HF and LF are 115$\pm$2 mJy/beam$\cdot$s$^{1/2}$ and 95$\pm$1 mJy/beam$\cdot$s$^{1/2}$, obtained using CONCERTO data on the COSMOS field for a mean precipitable water vapour and elevation of 0.81 mm and 55.7 deg. CONCERTO demonstrates unique capabilities in fast dual-band spectral mapping with a $\sim$18.5' instantaneous field-of-view. CONCERTO's performance in continuum is perfectly in line with expectations.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Spectral Data-cube Cleaning for CCAT Deep Spectroscopic Survey. I. Effect of correlated noise and filtering on the power spectrum

    astro-ph.GA 2026-07 conditional novelty 6.0

    The EoR-Spec Filter-and-Bin pipeline suppresses atmospheric 1/f noise by about four orders of magnitude and recovers the [CII]+CO power spectrum above k ~ 0.1 Mpc^-1, but suppresses large-scale modes below 20% transfe...