Pith. sign in

REVIEW 1 cited by

Chemically resolved nuclear magnetic resonance spectroscopy by longitudinal magnetization detection with a diamond magnetometer

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2503.02140 v1 pith:4K75FLEN submitted 2025-03-04 physics.ins-det physics.app-phphysics.chem-phphysics.opticsquant-ph

classification physics.ins-detphysics.app-phphysics.chem-phphysics.opticsquant-ph
keywords magneticdetectiondiamondfieldanalytechemicaldistortionlongitudinal
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Non-inductive magnetometers based on solid-state spins offer a promising solution for small-volume nuclear magnetic resonance (NMR) detection. A remaining challenge is to operate at a sufficiently high magnetic field to resolve chemical shifts at the part-per-billion level. Here, we demonstrate a Ramsey-M_z protocol that uses Ramsey interferometry to convert an analyte's transverse spin precession into a longitudinal magnetization (M_z), which is subsequently modulated and detected with a diamond magnetometer. We record NMR spectra at B0=0.32 T with a fractional spectral resolution of ~350 ppb, limited by the stability of the electromagnet bias field. We perform NMR spectroscopy on a ~1 nL detection volume of ethanol and resolve the chemical shift structure with negligible distortion. Through simulation, we show that the protocol can be extended to fields up to B0=3 T, with minimal spectral distortion, using composite nuclear-spin inversion pulses. For sub-nanoliter analyte volumes, we estimate a resolution of ~1 ppb and concentration sensitivity of ~40 mM s^{1/2} is feasible with improvements to the sensor design. Our results establish diamond magnetometers as high-resolution NMR detectors in the moderate magnetic field regime, with potential applications in metabolomics and pharmaceutical research.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators

    physics.ins-det 2025-06 conditional novelty 7.0 of 10

    An isotropic six-cone ferrite concentrator amplifies Earth's field about 19x over 98% of solid angle, resolving ODMR spectral congestion and enabling diamond vector magnetometry at 50 uT.

Pith tools