Core claim
Integrating targeted intra- and peri-ventricular patch sampling with a SwinUNETR architecture produces a mean DSC of 0.868 (95 percent CI 0.863-0.872) on the extended test set when MPRAGE and FLAIR are combined, a statistically significant improvement over UXNET while lowering computational load by 99 percent.
What carries the argument
Targeted sampling of 32x32x32 voxel patches centered on the ventricles, processed by a SwinUNETR transformer, to segment the full lateral ventricle choroid plexus.
If this is right
- The method maintains DSC 0.863 and low Hausdorff distance when only FLAIR is available.
- Computational cost falls to 91.8 GFLOPs, enabling deployment on standard hardware.
- Statistically superior performance holds across two independent MS cohorts totaling over 700 scans.
Where Pith is reading between the lines
- The same localized sampling could be adapted to other small periventricular structures that are currently segmented at high cost.
- If the patch strategy generalizes to lower-field or motion-corrupted scans, it could support routine clinical monitoring outside research centers.
Load-bearing premise
The assumption that small patches focused near the ventricles contain enough context to segment the entire choroid plexus without missing distant parts or creating edge errors.
What would settle it
Running the model on cases where the choroid plexus visibly extends outside the sampled patches and measuring whether Dice scores drop below the reported range.
read the original abstract
Background: The lateral ventricle choroid plexus (LVCP) is gaining recognition as a key imaging biomarker for multiple sclerosis (MS) related to physical disability and neuroinflammation. Yet, manual segmentation of the LVCP is highly tedious, restricting its use in broad clinical trials and longitudinal assessments. This research aims to develop a SwinUNETR-driven pipeline that leverages targeted intra- and peri-ventricular small patch sampling to automatically segment the LVCP in MS from both standalone and multi-modal MRI inputs. Methods: We retrospectively assessed 3T MRI scans across three sets of data stemming from two separate MS-dominant cohorts (Dataset 1: n=177; Dataset 2: n=177; expanded test set: n=388). Our method employed a SwinUNETR architecture trained on 32x32x32 voxel patches, benchmarking it against the 3D UXNET model. The primary metric for evaluation was the Dice Similarity Coefficient (DSC), supplemented by computational demand (GFLOPs) and the 95th percentile Hausdorff Distance (HD95). Results: On the extended test set, the SwinUNETR model secured a mean DSC of 0.868 (95% CI: 0.863-0.872) with MPRAGE and FLAIR combined, showing a statistically significant gain over UXNET (DSC: 0.858 [95% CI: 0.853-0.862], p<0.0001). When restricted to standalone FLAIR inputs, the transformer-based approach sustained a high DSC of 0.863, while the spatial localization of UXNET worsened considerably (HD95: 1.86 vs. 3.00 mm). Importantly, the proposed framework lowered computational load by 99% (91.8 vs. 22,080 GFLOPs). By integrating localized patch sampling with a SwinUNETR architecture, this methodology offers an accurate, robust, and statistically superior alternative to current leading models for LVCP segmentation. Its vast reduction in computational cost makes it ideal for widespread implementation in clinical and research environments.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript proposes a SwinUNETR pipeline for LVCP segmentation in MS that uses targeted intra- and peri-ventricular 32^3 patch sampling from MPRAGE and/or FLAIR MRI. On an extended test set of 388 scans it reports mean DSC 0.868 (95% CI 0.863-0.872) for the combined-modality case, statistically superior to UXNET (DSC 0.858, p<0.0001), together with a reduction from 22,080 to 91.8 GFLOPs.
Significance. If the patch-sampling premise holds, the work supplies a concrete route to deploy LVCP segmentation at scale in MS trials by cutting computational cost by two orders of magnitude while preserving or improving Dice scores; the explicit confidence intervals and hypothesis tests are a positive feature of the empirical reporting.
major comments (2)
- [Abstract] Abstract/Results: the reported DSC of 0.868 and the 99% GFLOPs reduction both presuppose that the upstream localization step places 32^3 patches so that every LVCP voxel is enclosed and that stitching produces no boundary artifacts. No coverage fraction, missed-voxel count, or ablation on patch stride/overlap is supplied, which directly undermines the claim that the localized method is reliably superior to full-volume UXNET.
- [Methods] Methods: the localization procedure that generates the intra-/peri-ventricular patches is described only at the level of 'targeted ... small patch sampling'; without an explicit algorithm, ventricle mask source, or guarantee that all LVCP voxels fall inside the sampled region, the generalizability of the 0.868 DSC across the two cohorts cannot be assessed.
minor comments (2)
- [Abstract] Abstract: the relationship between Dataset 1 (n=177), Dataset 2 (n=177) and the 'expanded test set (n=388)' is not stated; it is unclear whether the latter is an independent hold-out or contains the training/validation data.
- [Results] Results: the HD95 comparison for standalone FLAIR is given only as '1.86 vs. 3.00 mm'; the first number should be explicitly attributed to SwinUNETR.
Simulated Author's Rebuttal
We thank the referee for the detailed and constructive comments. We address each point below and will revise the manuscript to provide the requested details on the localization procedure.
read point-by-point responses
-
Referee: [Abstract] Abstract/Results: the reported DSC of 0.868 and the 99% GFLOPs reduction both presuppose that the upstream localization step places 32^3 patches so that every LVCP voxel is enclosed and that stitching produces no boundary artifacts. No coverage fraction, missed-voxel count, or ablation on patch stride/overlap is supplied, which directly undermines the claim that the localized method is reliably superior to full-volume UXNET.
Authors: We agree that explicit quantification of patch coverage, missed voxels, and boundary effects is needed to fully support the claims. In the revised manuscript we will add: (1) the fraction of LVCP voxels captured by the 32^3 patches, (2) any observed missed-voxel statistics on the test set, and (3) an ablation on patch stride/overlap. These additions will directly address the concern that the reported superiority may rest on unverified localization assumptions. revision: yes
-
Referee: [Methods] Methods: the localization procedure that generates the intra-/peri-ventricular patches is described only at the level of 'targeted ... small patch sampling'; without an explicit algorithm, ventricle mask source, or guarantee that all LVCP voxels fall inside the sampled region, the generalizability of the 0.868 DSC across the two cohorts cannot be assessed.
Authors: We acknowledge the description of the localization step is currently high-level. The revised Methods section will include: the explicit algorithm (including how intra- and peri-ventricular regions are defined), the source of the ventricle masks used for patch placement, and empirical verification that all annotated LVCP voxels lie within the sampled patches on both cohorts. This will allow readers to evaluate generalizability. revision: yes
Circularity Check
No circularity: empirical ML segmentation study with held-out evaluation
full rationale
This paper presents an empirical machine-learning pipeline for LVCP segmentation using SwinUNETR trained on 32^3 patches, benchmarked against UXNET on independent test sets (n=388). All reported results (DSC 0.868, GFLOPs reduction, statistical tests) are computed directly from held-out data splits with no derivations, first-principles predictions, or fitted quantities that reduce to the inputs by construction. No self-citation load-bearing steps, uniqueness theorems, or ansatzes appear in the described method; the localized patch sampling is a design choice whose validity is assessed empirically rather than assumed tautologically. The central claims rest on external test-set performance, satisfying the criteria for a self-contained, non-circular empirical study.
Axiom & Free-Parameter Ledger
free parameters (2)
- patch size =
32x32x32
- training hyperparameters
axioms (1)
- domain assumption Localized patches contain sufficient information for accurate LVCP segmentation
Reference graph
Works this paper leans on
-
[1]
Kolahi S, Zarei D, Issaiy M, Shakiba M, Azizi N, Firouznia K. Choroid plexus volume changes in mulƟple sclerosis: insights from a systemaƟc review and meta-analysis of magneƟc resonance imaging studies. Neuroradiology. 2024;c:1869–1886. doi: 10.1007/s00234-024-03439-3. Cited in PMID: 39105769
-
[2]
Choroid Plexus Volume Change—A Candidate for a New Radiological Marker of MS Progression
Jankowska A, Chwojnicki K, Grzywińska M, Trzonkowski P , Szurowska E. Choroid Plexus Volume Change—A Candidate for a New Radiological Marker of MS Progression. DiagnosƟcs. 2023;13. doi: 10.3390/diagnosƟcs13162668
-
[3]
Pathogenesis of Alzheimer’s disease: Involvement of the choroid plexus
Čarna M, Onyango IG, KaƟna S, Holub D, Novotny JS, Nezvedova M, Jha D, Nedelska Z, Lacovich V, Vyvere T Vande, et al. Pathogenesis of Alzheimer’s disease: Involvement of the choroid plexus. Alzheimer’s and DemenƟa. 2023;19:3537–3554. doi: 10.1002/alz.12970. Cited in PMID: 36825691
-
[4]
Jeong SH, Park CJ, Jeong HJ, Sunwoo MK, Ahn SS, Lee SK, Lee PH, Kim YJ, Sohn YH, Chung SJ. AssociaƟon of choroid plexus volume with motor symptoms and dopaminergic degeneraƟon in Parkinson’s disease. Journal of Neurology, Neurosurgery and Psychiatry. 2023;94:1047–1055. doi: 10.1136/jnnp-2023-331170. Cited in PMID: 37399288
-
[5]
Magliozzi R, Hametner S, Mastantuono M, Mensi A, Karimian M, Griffiths L, Watkins LM, Poli A, BerƟ GM, Barusolo E, et al. Neuropathological and cerebrospinal fluid correlates of choroid plexus inflammaƟon in progressive mulƟple sclerosis. Brain Pathology. 2024;1–20. doi: 10.1111/bpa.13322
-
[6]
Chronic AcƟve Lesions and Larger Choroid Plexus Explain CogniƟon and FaƟgue in MulƟple Sclerosis
Preziosa P , Pagani E, Meani A, Storelli L, Margoni M, Yudin Y , Tedone N, Biondi D, Rubin M, Rocca MA, et al. Chronic AcƟve Lesions and Larger Choroid Plexus Explain CogniƟon and FaƟgue in MulƟple Sclerosis. Neurol Neuroimmunol Neuroinflamm. 2024;11:e200205. doi: 10.1212/NXI.0000000000200205
-
[7]
BarbuƟ E, ConƟ A, Treaba CA, Miscioscia A, BarleƩa VT , Herranz E, Sloane JA, Klawiter EC, Toschi N, Mainero C. Choroid Plexus Enlargement in MulƟple Sclerosis Correlates with CorƟcal and Phase Rim Lesions on 7T MRI and Predicts Progression Independent of Relapse AcƟvity. AJNR Am J Neuroradiol. 2026;47:557–565. doi: 10.3174/ajnr.A8983
-
[8]
Ricigliano VAG, Morena E, Colombi A, TonieƩo M, Hamzaoui M, Poirion E, BoƩlaender M, Gervais P , Louapre C, Bodini B, et al. Choroid Plexus Enlargement in Inflammatory MulƟple Sclerosis: 3.0-T MRI and Translocator Protein PET EvaluaƟon. Radiology. 2021;301:166–177. doi: 10.1148/radiol.2021204426
-
[9]
Müller J, Noteboom S, Granziera C, Schoonheim MM. Understanding the Role of the Choroid Plexus in MulƟple Sclerosis as an MRI Biomarker of Disease AcƟvity. Neurology. 2023;100:405–406. doi: 10.1212/WNL.0000000000206806. Cited in PMID: 36543568
-
[10]
Müller J, Sinnecker T, Wendebourg MJ, Schläger R, Kuhle J, Schädelin S, Benkert P , Derfuss T , Caƫ n P , Jud C, et al. Choroid Plexus Volume in MulƟple Sclerosis vs NeuromyeliƟs OpƟca Spectrum Disorder: A RetrospecƟve, Cross-secƟonal Analysis. Neurol Neuroimmunol Neuroinflamm. 2022;9:e1147. doi: 10.1212/NXI.0000000000001147. Cited in PMID: 35217580
-
[11]
Li J, Gao Y , Xu Y , Dai W, Hu Y , Feng X, Wu D, Zhao L. Morphological changes of the choroid plexus in the lateral ventricle across the lifespan: 5551 subjects from fetus to elderly. NeuroImage. 2025;318:121392. doi: 10.1016/j.neuroimage.2025.121392
-
[12]
ASCHOPLEX : a generalizable approach for the automaƟc segmentaƟon of choroid plexus
Visani V, Veronese M, Pizzini FB, Colombi A, Marjin C, TamanƟ A, Schubert JJ, Althubaity N, Harrison NA, Bullmore ET , et al. ASCHOPLEX : a generalizable approach for the automaƟc segmentaƟon of choroid plexus. 2024;182. doi: 10.1016/j.compbiomed.2024.109164
-
[13]
U-Net: ConvoluƟonal Networks for Biomedical Image SegmentaƟon [Internet]
Ronneberger O, Fischer P , Brox T. U-Net: ConvoluƟonal Networks for Biomedical Image SegmentaƟon [Internet]. arXiv; 2015 [cited 2025 Nov 24]. Available from: hƩps://arxiv.org/abs/1505.04597
Pith/arXiv arXiv 2015
-
[14]
doi:10.1016/j.neuroimage.2012.01.021
Fischl B. FreeSurfer. NeuroImage. 2012;62:774–781. doi: 10.1016/j.neuroimage.2012.01.021
-
[15]
Lu P-J, Cagol A, Ocampo-Pineda M, Mastantuono M, Aldea A-A, Müller J, Yaldizli Ö, Weigel M, Melie-Garcia L, Magliozzi R, et al. Deep learning-based SegmentaƟon of the Choroid Plexus in MulƟple Sclerosis Using MPRAGE, FLAIR, and MP2RAGE. Mult Scler . 2025;31:1032. doi: 10.1177/13524585251358343
-
[16]
Swin UNETR: Swin Transformers for SemanƟc SegmentaƟon of Brain Tumors in MRI Images [Internet]
Hatamizadeh A, Nath V, Tang Y , Yang D, Roth H, Xu D. Swin UNETR: Swin Transformers for SemanƟc SegmentaƟon of Brain Tumors in MRI Images [Internet]. arXiv; 2022 [cited 2026 Feb 4]. Available from: hƩp://arxiv.org/abs/2201.01266
arXiv 2022
-
[17]
Lee HH, Bao S, Huo Y , Landman BA. 3D UX-Net: A Large Kernel Volumetric ConvNet Modernizing Hierarchical Transformer for Medical Image SegmentaƟon [Internet]. arXiv; 2022 [cited 2025 Nov 24]. Available from: hƩps://arxiv.org/abs/2209.15076
arXiv 2022
-
[18]
Wang X, Wang X, Yan Z, Yin F, Li Y , Liu X, Liu Y . Enhanced choroid plexus segmentaƟon with 3D UX-Net and its associaƟon with disease progression in mulƟple sclerosis. MulƟple Sclerosis and Related Disorders. 2024;88:105750. doi: 10.1016/j.msard.2024.105750
-
[19]
Eisma JJ, McKnight CD, HeƩ K, Elenberger J, Han CJ, Song AK, Considine C, Claassen DO, Donahue MJ. Deep learning segmentaƟon of the choroid plexus from structural magneƟc resonance imaging (MRI): validaƟon and normaƟve ranges across the adult lifespan. Fluids Barriers CNS. 2024;21:21. doi: 10.1186/s12987-024-00525-9
-
[20]
Isensee F, Schell M, Pflueger I, Brugnara G, Bonekamp D, Neuberger U, Wick A, Schlemmer H, Heiland S, Wick W, et al. Automated brain extracƟon of mulƟsequence MRI using arƟficial neural networks. Human Brain Mapping. 2019;40:4952–4964. doi: 10.1002/hbm.24750
-
[21]
TusƟson NJ, Cook PA, Holbrook AJ, Johnson HJ, Muschelli J, Devenyi GA, Duda JT, Das SR, Cullen NC, Gillen DL, et al. The ANTsX ecosystem for quanƟtaƟve biological and medical imaging. Sci Rep. 2021;11:9068. doi: 10.1038/s41598-021-87564-6
-
[22]
A contrast-adapƟve method for simultaneous whole-brain and lesion segmentaƟon in mulƟple sclerosis
Cerri S, PuonƟ O, Meier DS, Wuerfel J, Mühlau M, Siebner HR, Van Leemput K. A contrast-adapƟve method for simultaneous whole-brain and lesion segmentaƟon in mulƟple sclerosis. NeuroImage. 2021;225:117471. doi: 10.1016/j.neuroimage.2020.117471
-
[23]
NeuroImage62(2), 782–790 (2012)
Jenkinson M, Beckmann CF, Behrens TEJ, Woolrich MW , Smith SM. Review FSL. NeuroImage. 2012; doi: 10.1016/j.neuroimage.2011.09.015
-
[24]
Yushkevich PA, Piven J, HazleƩ HC, Smith RG, Ho S, Gee JC, Gerig G. User-guided 3D acƟve contour segmentaƟon of anatomical structures: Significantly improved efficiency and reliability. NeuroImage. 2006;31:1116–1128. doi: 10.1016/j.neuroimage.2006.01.015
-
[25]
Focal Loss for Dense Object DetecƟon
Lin T-Y , Goyal P , Girshick R, He K, Dollár P . Focal Loss for Dense Object DetecƟon. 2017
2017
-
[26]
Decoupled weight decay regularizaƟon
Loshchilov I, HuƩer F. Decoupled weight decay regularizaƟon. 7th InternaƟonal Conference on Learning RepresentaƟons, ICLR 2019. 2019
2019
-
[27]
Metrics for evaluaƟng 3D medical image segmentaƟon: analysis, selecƟon, and tool
Taha AA, Hanbury A. Metrics for evaluaƟng 3D medical image segmentaƟon: analysis, selecƟon, and tool. BMC Med Imaging. 2015;15:29. doi: 10.1186/s12880-015-0068-x
-
[28]
FastSurfer - A fast and accurate deep learning based neuroimaging pipeline
Henschel L, ConjeƟ S, Estrada S, Diers K, Fischl B, Reuter M. FastSurfer - A fast and accurate deep learning based neuroimaging pipeline. NeuroImage. 2020;219:117012. doi: 10.1016/j.neuroimage.2020.117012
-
[29]
Palaniappan D, Jain R, Premavathi T, Parmar K, Ghribi W, Ahmed AM, Ahmad N. YOLO in Healthcare: A Comprehensive Review of DetecƟon Architectures, Domain ApplicaƟons, and Future InnovaƟons. IEEE Access. 2025;13:145714–145735. doi: 10.1109/ACCESS.2025.3599358. Figures Figure 1. Lateral ventricle choroid plexus segmentaƟon of a person with mulƟple sclerosis....
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.