The paper says

“In electro-optic (EO) sampling, increasing the probe power enhances the EO signal, but the usable power can be limited by photodetector saturation caused by the much larger probe background independent of the applied electric field.”

more of the abstract

Here, we propose a method for suppressing this background through destructive interference between an EO-modulated probe and an unmodulated reference beam. Using a Jones-matrix model, we compare five detection configurations and identify balanced detection as suitable for maintaining a linear weak-field response under strong background suppression. This suppression allows higher input optical power to be used without saturating the photodiodes, thereby enhancing the EO signal. Under a per-photodiode saturation constraint, the optimized signal enhancement scales approximately as the square root of the total input power. For a total input power of 5 W and a saturation limit of 5 mW per photodiode, the optimized configuration yields an approximately 12-fold signal enhancement over conventional balanced detection.

from the abstract

Pith says

Machine review · deepseek-v4-flash · 13 Nov 2026 · what was read was not recorded · not checked by a person

It can be wrong. Challenge this review or reply to it.

Holds up. A clean theoretical paper showing that a finite positive amplitude imbalance in a QWP-PBS balanced interferometer restores linear weak-field response in EO sampling, with a square-root power-scaling law for signal enhancement under detector saturation. This line is wrong

3 major objections · 6 minor

How often objections from reviews like this one are right: not yet measured

Are you an author? What you can do.

Not checked: figures, code, what the 37 references say.

The paper says, at §3.A, Eq. (38)–(39)

The review did not quote this passage.

Pith says: Objection 1 of 3 · major

The optimization enforces Pdet(0)=Psat, but the saturation constraint (35) is Itot(Δϕ)≤Isat, i.e., the maximum per-diode power at the actual EO retardation. At the optimum δopt≈0.0447 and |Δϕ|=2.2×10⁻³ rad, one photodiode reaches about 5.13 mW, a ~2.6% excess over Psat. Re-solving the constraint at the maximum |Δϕ| lowers δopt to about 0.0441 and G from ~11.7 to ~11.5, within the stated approximate value.

more of objection 1

The authors should clarify whether the optimization is performed at Δϕ=0 or at the maximum expected retardation, and discuss the impact on the quoted enhancement factor.

The paper says, at §2, sentence b37

The review did not quote this passage.

A classifier read this sentence of the paper as acknowledging the concern (probability 0.79):

“In practice, imperfect matching may reduce the interference contrast and limit the achievable background suppression.”

Pith says: Objection 2 of 3 · major

The model assumes perfect spatial mode, polarization, and frequency matching between probe and reference. The authors acknowledge this limitation (b38), but it is load-bearing because the entire suppression mechanism depends on coherent cancellation. The paper would benefit from a quantitative estimate of how contrast degradation (e.g., due to imperfect mode overlap or frequency mismatch) reduces the achievable enhancement, even if only as a scaling argument or a reference to known interferometric visibility effects.

The paper says, at §3.A, Eq. (36)–(39)

The review did not quote this passage.

Pith says: Objection 3 of 3 · major

The enhancement factor G is defined relative to conventional balanced detection at the same per-photodiode saturation limit. However, the conventional reference is operated without a reference beam (δ=1/2) and its input power is adjusted until Itot=Isat. This is a fair baseline, but the comparison assumes that the conventional detection also uses the same PBS and QWP, which is reasonable.

more of objection 3

The authors should explicitly state that the conventional reference corresponds to δ=1/2 and that its input power is set to achieve the same saturation condition, to avoid ambiguity.

6 minor objections

The paper says, at §2, Eq. (5)–(7)

Pith says: minor objection 1 of 6

The notation E0 is introduced as a real normalization amplitude, but it appears in both the probe and reference fields. It would be helpful to explicitly state that ∥Eprobe∥² + ∥Eref∥² = 2E0², which is given but could be emphasized.

The paper says, at §2, Eq. (14)

Pith says: minor objection 2 of 6

The definition of Itot as the maximum over photodiodes is clear, but the notation 'max_{1≤j≤jmax}' could be misinterpreted. Consider rephrasing as 'the maximum intensity among the photodiodes' for clarity.

show 4 more

The paper says, at §3.A, Fig. 6

Pith says: minor objection 3 of 6

The color scale in Fig. 6(a) is not explicitly described in the caption. The hatched region indicates saturation, but the color mapping for G values should be explained (e.g., logarithmic or linear scale).

The paper says, at §2, Eq. (19)

Pith says: minor objection 4 of 6

The polarizer Jones matrix uses 10^{-OD/2} for the rejected component. It would be helpful to note that this assumes the transmitted component has unit transmission, which is stated but could be reiterated.

The paper says, at §3.B, Eq. (41)

Pith says: minor objection 5 of 6

The ratio |I^{(3)}/I^{(1)}| is given as a function of δ and Δϕ. The authors state that it is independent of Pin, which is correct within the model. However, the dependence on δ through the prefactor could be simplified for clarity.

The paper says, at §4, Conclusion

Pith says: minor objection 6 of 6

The conclusion mentions potential applications to vacuum birefringence and axion-induced polarization effects. These are intriguing but speculative; the authors should consider adding a brief caveat that the current model does not include quantum noise or other relevant effects for those extreme weak-field regimes.

What would settle it

Recompute δopt using the exact balanced-detection photodiode intensities (Eqs. (23)–(26)) with the constraint max_j Pdet,j(|Δϕ|)≤Psat at ε=0, Pin=5W, Psat=5mW, |Δϕ|=2.2×10−3, instead of using Pdet(0)=Psat in Eq. (38); if G remains above 11, the quoted enhancement and scaling stand. As a diagnostic, repeat at |Δϕ|=0.08 rad, the upper end of the stated 1% linearity range, and check whether the required reduction in δopt is large enough to affect the claimed √Pin behavior.

from the skeptic's reading

How the review went

4 readings by deepseek-v4-flash · 13 Nov 2026

  1. Reader holds up confidence moderate
  2. Skeptic partly agrees 2 min 54 s · 17,146 tokens read, 27,359 written
  3. Editor wrote the verdict above 8 s · 18,081 tokens read, 626 written
  4. Referee minor revision: 3 major objections, 6 minor 12 s · 17,582 tokens read, 1,194 written

Not run on this paper: the simulated authors' defence.

Pith did not check this review's objections against the paper.

The review in full

The review in brief, machine-written

Hiro,

This is a clean theoretical paper. The core result is that in an interferometric background-suppression scheme for EO sampling, balanced detection retains a first-order response to the THz field at finite positive amplitude imbalance, whereas exact background cancellation leaves a cubic leading response. Under a per-photodiode saturation constraint, the optimized enhancement scales as sqrt(Pin), giving roughly a 12-fold differential signal enhancement over conventional balanced detection at Pin = 5 W and Psat = 5 mW. The derivation is self-contained, the Jones-matrix expansions are internally consistent, and the closed-form optimum (Eq. 39) reproduces the quoted 12-fold number. The paper also systematically compares five detection configurations, which is useful for anyone designing an EO sampling setup.

What it does well: it identifies a design rule that is not in the prior literature, it gives an explicit analytic formula for the optimum amplitude imbalance, and it shows that the balanced-detection configuration is phase-robust (first-order insensitivity of the response coefficient at ε=0). The analysis of waveform distortion (cubic vs linear) is also careful.

Soft spots: the paper is entirely theoretical with no experimental validation. The authors acknowledge the key idealizations (perfect mode matching, monochromatic probe, lossless crystal, etc.) in Sec. 2, so that is not a hidden flaw. The stress-test note raises a minor point about the saturation constraint being enforced at zero-field power rather than at the maximum |Δφ|, but the correction is <2% and does not affect the √Pin scaling. That is a genuine nuance but not a load-bearing flaw. The paper also does not address shot-noise or technical noise beyond stating that the signal enhancement translates to SNR improvement in the shot-noise-limited regime; a more detailed noise analysis would strengthen the practical case but is not required for the theoretical claim.

Who this is for: researchers in EO sampling, THz spectroscopy, and accelerator diagnostics who want to push the probe power beyond the detector saturation limit. The paper gives a clear design target (δopt, Gopt) and identifies the balanced-detection configuration as the most phase-robust option.

Recommendation: This paper deserves a serious referee. The theory is sound, the result is new, and the limitations are stated. I would send it to peer review. I would not cite it in my own work in the next 12 months because I work in a different area, but I would bring it to a reading group if someone in the group works on EO sampling.

The strongest objection

The central derivation is sound: Eq. (26) gives a first-order balanced-detection coefficient at ε=0, δ>0, and Eqs. (36)–(39) follow from setting the zero-field per-diode power in Eq. (37) to Psat. At Pin=5W and Psat=5mW, Eq. (39) gives Gopt≈11.7, matching the quoted 12-fold enhancement. The main practical caveat, imperfect spatial/polarization/frequency matching between probe and reference (b37, b38), is explicitly acknowledged and is a scope condition of the model rather than a hidden flaw. The one technical point not explicitly addressed is that the stated saturation constraint (35) is Itot(Δϕ)≤Isat, while the optimization (38) enforces only Pdet(0)=Psat. At |Δϕ|=2.2×10−3, δopt≈0.0447 leaves one photodiode at about 5.13mW, a ~2.6% excess. Re-solving the constraint at the maximum |Δϕ| lowers δopt to about 0.0441 and G from ~11.7 to ~11.5, within the stated approximate value; the √Pin scaling is unchanged. Thus no load-bearing objection lands.

The reader accepted the paper on the basis of internal consistency, with MODERATE confidence and the acknowledged mode-matching idealization as the weakest assumption. My independent pass reproduces the first-order coefficient in Eq. (26) and the optimization in Eqs. (36)–(39), so the central claim is mathematically supported as stated. The mode-matching limitation is real but explicitly scoped in the model (b37, b38), and the paper is a theory contribution rather than an experimental demonstration, so it does not require experimental validation for acceptance. The only nuance I found that is not explicitly acknowledged is the difference between the exact saturation constraint (35) and the zero-field saturation condition used in Eq. (38); at the quoted operating point this changes G by about 1–2%, which does not alter the approximately 12-fold claim or the square-root scaling. For this reason the reader's ACCEPT verdict should stand unchanged.

The referee's report

If the predicted enhancement is realized experimentally, the scheme could substantially improve the sensitivity of EO sampling for weak-field detection, particularly in applications where probe power is abundant but detector saturation limits the usable power. The analytic scaling law (√Pin) and the identification of balanced detection as the preferred configuration provide clear design guidance. The paper is primarily theoretical, but the model is transparent and the key results are expressed in closed form, making them testable.

Pith's reading of the paper (a machine's summary, not the authors')

This paper proposes using destructive interference between an electro-optically modulated probe beam and an unmodulated reference beam to suppress the large field-independent background that limits the probe power in electro-optic sampling. By operating a Mach–Zehnder interferometer at a finite positive amplitude imbalance rather than at exact background cancellation, the balanced-detection output retains a linear response to the THz field while canceling even-order distortion. Under a per-photodiode saturation constraint, the optimized signal enhancement scales as the square root of the total input power, yielding roughly a 12-fold improvement over conventional balanced detection at 5 W input power and 5 mW per photodiode saturation. The scheme is also shown to be insensitive to small interferometer phase fluctuations to first order, making it robust against mechanical vibrations.

What carries the argument. The central mechanism is destructive interference between an EO-modulated probe and an unmodulated reference beam in a Mach–Zehnder interferometer, combined with a quarter-wave plate and polarizing beam splitter (balanced detection). The key identity is the differential output Idiff ∝ cos 2χ [sqrt(1-4δ²) cos ε - (1+2δ)] Δϕ + O(Δϕ³), where δ is the amplitude imbalance and ε the phase imbalance. This expression shows that at δ > 0 and ε = 0 the first-order term is nonzero and its coefficient is stationary against small phase errors, whereas at δ = ε = 0 the first-order term vanishes and the leading response is cubic.

Core claim. The paper establishes that in an interferometric background-suppression scheme for electro-optic sampling, balanced detection with a finite positive amplitude imbalance (δ > 0) preserves a linear first-order response to the THz electric field, whereas operating at exact background cancellation (δ = ε = 0) eliminates the linear term and leaves only a cubic leading response. The differential output of balanced detection cancels all even-order contributions, eliminating second-order waveform distortion. The first-order response coefficient at zero phase imbalance is stationary against small phase fluctuations (∂K_bal_1/∂ε = 0 at ε = 0), providing phase-robust operation. Under a per-photodiode saturation constraint, the amplitude imbalance that maximizes the differential signal is given analytically by δ_opt = (1/2) sqrt(1 - (1 - 4P_sat/P_in)²), yielding an optimized enhancement G_opt = 1/2 + sqrt(P_in/(8 P_sat) - 1/4). For P_in = 5 W and P_sat = 5 mW per photodiode, this gives approximately a 12-fold signal enhancement over conventional balanced detection, with a cubic contribution only ~7.2 × 10⁻⁶ times the linear contribution at |Δϕ| = 2.2 × 10⁻³ rad.

The premise it rests on. The analysis assumes that the probe and reference beams are perfectly matched in spatial mode, polarization, and optical frequency; if real beams are imperfectly matched, interference contrast drops, residual unmodulated background consumes detector dynamic range, and the calculated optimum amplitude imbalance and 12-fold enhancement are not reached.

If the paper is right (Pith's inferences, not the authors')

Balanced detection with a small positive amplitude imbalance yields a linear response to the THz field, while exact background cancellation eliminates the linear term and leaves a cubic response; this means that operating exactly at the dark fringe is counterproductive for linear EO sampling.

The differential output cancels all even-order contributions, so second-order waveform distortion from the quadratic term in the EO response is eliminated without requiring optical-bias reversal or nonlinear post-processing.

Under a per-photodiode saturation constraint, the optimal enhancement scales as the square root of the total input power: G_opt = 1/2 + sqrt(P_in/(8 P_sat) - 1/4). For P_in = 5 W and P_sat = 5 mW per photodiode, this gives roughly a 12-fold signal enhancement over conventional balanced detection.

The first-order response coefficient in balanced detection is insensitive to small phase fluctuations to first order around zero phase imbalance (∂K_bal_1/∂ε = 0 at ε = 0), making the scheme robust against mechanical vibrations of the interferometer.

Polarization filtering and interferometric suppression act multiplicatively: the crossed-Nicols configuration with a finite-extinction polarizer shows that interferometric cancellation can further suppress the coherent background transmitted through the polarizer.

The same interferometric suppression principle could be applied to other weak-phase-retardation measurements, such as vacuum birefringence searches or magneto-optical Kerr effect detection, where a strong background must be suppressed to reveal a tiny polarization or phase shift.

Because the enhancement scales as sqrt(P_in) at the optimum, further gains require quadratically larger total input power; at P_in = 50 W the predicted enhancement would be ~35-fold, but practical limits from spatial-mode matching and interferometer stability would become more severe.

The analysis assumes perfect spatial-mode matching; in a real setup, wavefront errors and beam-pointing fluctuations will reduce the interference contrast and thus the achievable background suppression. A quantitative model of contrast reduction (e.g., via a visibility parameter) would be a natural extension to bound the practical enhancement.

Check this review

Pith stored no record of this review's passes and took no fingerprint of it. Reviews made by code from 13 Nov 2026 on carry both.

How often reviews like this one are right

Reviews like this one: written by deepseek-v4-flash, where what was read was not recorded.

How often objections from reviews like this one are right: not yet measured

Every value above, in the review's public record (JSON)

Reviews by people

This review was written by a machine. No person has reviewed this paper on Pith yet. A scientist listed on Pith can review it for a fee, and their review is published here whatever it concludes.

Request a human review

How Pith checks papers · The full audit of this paper

The paper

Abstract

In electro-optic (EO) sampling, increasing the probe power enhances the EO signal, but the usable power can be limited by photodetector saturation caused by the much larger probe background independent of the applied electric field. Here, we propose a method for suppressing this background through destructive interference between an EO-modulated probe and an unmodulated reference beam. Using a Jones-matrix model, we compare five detection configurations and identify balanced detection as suitable for maintaining a linear weak-field response under strong background suppression. This suppression allows higher input optical power to be used without saturating the photodiodes, thereby enhancing the EO signal. Under a per-photodiode saturation constraint, the optimized signal enhancement scales approximately as the square root of the total input power. For a total input power of 5 W and a saturation limit of 5 mW per photodiode, the optimized configuration yields an approximately 12-fold signal enhancement over conventional balanced detection.

The paper's own sentences, arranged, kept beside the review and separate from it. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. No sentence in this record was written by a model.

abstract compiled · 2026-11-13

The authors' main claim, as the classifier picked it out 0.59

“For a total input power of 5 W and a saturation limit of 5 mW per photodiode, the optimized configuration yields an approximately 12-fold signal enhancement over conventional balanced detection.”

How the main claim is stated: asserted 0.96

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.45 · human participants 0.02 · controlled comparison 0.83 · randomized assignment 0.01 · states quantitative result 0.98 · compares with prior results 0.89 · mentions code or data availability 0.02

The abstract, sentence by sentence

This table labels the abstract only (arXiv listing abstract v1). The number is the probability the classifier gave the label.

SentenceRoleThe authors' own workStates the main conclusionStrength
In electro-optic (EO) sampling, increasing the probe power enhances the EO signal, but the usable power can be limited by photodetector saturation caused by the much larger probe background independent of the applied electric field. background 1.00 0.12 0.03 asserted 0.97
Here, we propose a method for suppressing this background through destructive interference between an EO-modulated probe and an unmodulated reference beam. contribution 0.81 0.72 0.18 asserted 0.86
Using a Jones-matrix model, we compare five detection configurations and identify balanced detection as suitable for maintaining a linear weak-field response under strong background suppression. method 0.60 0.93 0.17 asserted 1.00
This suppression allows higher input optical power to be used without saturating the photodiodes, thereby enhancing the EO signal. interpretation 0.75 0.61 0.33 asserted 0.99
Under a per-photodiode saturation constraint, the optimized signal enhancement scales approximately as the square root of the total input power. result 0.99 0.87 0.22 asserted 0.88
For a total input power of 5 W and a saturation limit of 5 mW per photodiode, the optimized configuration yields an approximately 12-fold signal enhancement over conventional balanced detection. result 1.00 0.87 0.35 asserted 0.96

What kind of paper the classifier reports this is: method or tool 0.80 · evidence from proof or derivation 0.97

What was examined, and what was not

Sources read

  • arXiv listing abstract v1

Not examined

  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers

Levels run

  • P abstract

Not run

  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

How the labels were made

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-11-13: 1 request, 4,974 input tokens.

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. This record as JSON

Figures (6)
Figure 1 of the paper
Figure 1. Schematic of the proposed interferometric background￾suppression scheme for electro-optic (EO) sampling based on a Mach–Zehnder interferometer. M, mirror; NPBS, non￾polarizing beam splitter; EOC, electro-optic crystal; BPF, band￾pass filter; CW laser, continuous-wave laser. The CW laser is introduced to stabilize the destructive-interference condi￾tion. The optical power at the dark port is monitored by the detector behind BPF2 and used as a feedback signal for the feedback circuit, which controls the piezoelectric stage (Piezo) to maintain destructive interference. BPF1 blocks the…
Figure 2 of the paper
Figure 2. Schematics of background-suppressed electro-optic (EO) configurations without polarization-analysis optics in front of the detector. The probe polarization is fixed, while the EO crystal and the THz polarization are rotated together so that their relative orientation remains unchanged: (a) α = 0°, where the crystallographic [1¯10] axis and the THz polarization are parallel to the probe polarization, and (b) α = 45°, where the crystallographic [1¯10] axis and the THz polarization are oriented at 45° with respect to the probe polarization. NPBS: non-polarizing beam splitter.…
Figure 3 of the paper
Figure 3. Calculated two-dimensional color maps of the normal￾ized THz-induced signal and first-order signal for α = 0° and 45° as functions of the amplitude imbalance δ and phase im￾balance ε. The upper row corresponds to α = 0°: (a) Isig/Itot and (b) I (1)/Itot. The lower row corresponds to α = 45°: (c) |Isig|/Itot and (d) |I (1) |/Itot. Panels (a), (c), and (d) are plotted on logarithmic color scales with a common lower bound of 10−9 , whereas panel (b), which is identically zero over the en￾tire parameter range, is plotted on a linear color scale. The corresponding detected intensity is…
Figure 5 of the paper
Figure 5. Calculated two-dimensional color maps of the nor￾malized THz-induced signal and first-order signal for the crossed-Nicols, balanced-detection, and phase-offset configu￾rations as functions of the amplitude imbalance δ and phase imbalance ε. The upper row corresponds to the crossed-Nicols configuration with OD = 3: (a) Isig/Itot and (b) I (1)/Itot. The middle row corresponds to the balanced-detection configura￾tion with a PBS extinction ratio of cot2 χ = 103 : (c) Isig/Itot and (d) |I (1) |/Itot. The lower row corresponds to the phase-offset configuration with θ = 0.1° and OD = 3:…
Figure 6 of the paper
Figure 6. (a) shows the enhancement factor as a function of Pin and δ at ε = 0; the hatched region denotes detector saturation. For each Pin, we optimize G over the 0 < δ ≤ 1/2 branch subject to Eq. (35). The behavior of the optimum can be obtained analytically in the weak-field limit. At ε = 0, the first-order enhancement factor is G(δ) = Pin 8Psat h 1 + 2δ − p 1 − 4δ 2 i , (36) where the conventional balanced-detection reference is operated at the same per-photodiode saturation limit. Since G increases monotonically for 0 < δ < 1/2, the optimum is the largest δ allowed by detector…

Showing 5 of the paper's 6 figures. Figures are the authors', reproduced from the paper.

References (37)
  1. [1] J. A. Valdmanis, G. A. Mourou, and C. W. Gabel, “Subpicosecond electrical sampling,” IEEE J. Quantum Electron.19, 664–667 (1983) on Pith
  2. [2] D. H. Auston, K. P . Cheung, J. A. Valdmanis, and D. A. Kleinman, “Cherenkov radiation from femtosecond optical pulses in electro-optic media,” Phys. Rev. Lett.53, 1555–1558 (1984) on Pith
  3. [3] Q. Wu and X.-C. Zhang, “Free-space electro-optic sampling of terahertz beams,” Appl. Phys. Lett.67, 3523–3525 (1995) on Pith
  4. [4] I.-C. Benea-Chelmus, J. Faist, A. Leitenstorfer,et al., “Electro-optic sampling of classical and quantum light,” Optica12, 546–563 (2025) on Pith
  5. [5] L. Duvillaret, F . Garet, and J.-L. Coutaz, “A reliable method for extrac- tion of material parameters in terahertz time-domain spectroscopy,” IEEE J. Sel. Top. Quantum Electron.2, 739–746 (1996) on Pith
  6. [6] M. Koch, D. M. Mittleman, J. Ornik, and E. Castro-Camus, “Terahertz time-domain spectroscopy,” Nat. Rev. Methods Primers3, 48 (2023). Research Article 10 on Pith
  7. [7] I. Pupeza, M. Huber, M. Trubetskov,et al., “Field-resolved infrared spectroscopy of biological systems,” Nature577, 52–59 (2020) on Pith
  8. [8] D. Okazaki, M. Koch, M. Aghakasiri,et al., “1-THz-to-mid-infrared field- resolved spectrometer driven by a Cr:ZnS oscillator,” Opt. Express34, 28928–28942 (2026) on Pith
  9. [9] T. Kampfrath, M. Battiato, P . Maldonado,et al., “Terahertz spin current pulses controlled by magnetic heterostructures,” Nat. Nanotechnol.8, 256–260 (2013) on Pith
  10. [10] M. Sotome, M. Nakamura, T. Morimoto,et al., “Terahertz emission spectroscopy of ultrafast exciton shift current in the noncentrosymmet- ric semiconductor CdS,” Phys. Rev. B103, L241111 (2021) on Pith
  11. [11] R. Pompili, M. P . Anania, F . Bisesto,et al., “Ultrafast evolution of electric fields from high-intensity laser–matter interactions,” Sci. Reports8, 3243 (2018) on Pith
  12. [12] G. Berden, W. A. Gillespie, S. P . Jamison,et al., “Benchmarking of electro-optic monitors for femtosecond electron bunches,” Phys. Rev. Lett.99, 164801 (2007) on Pith
  13. [13] M. Ota, K. Kan, S. Komada,et al., “Longitudinal and transverse spatial beam profile measurement of relativistic electron bunch by electro-optic sampling,” Appl. Phys. Express14, 026503 (2021) on Pith
  14. [14] M. Ota, K. Kan, S. Komada,et al., “Ultrafast visualization of an electric field under the Lorentz transformation,” Nat. Phys.18, 1436–1440 (2022) on Pith
  15. [15] K. Huang, Z. Jin, N. Nakanii,et al., “Electro-optic 3D snapshot of a laser wakefield accelerated kilo-ampere electron bunch,” Light. Sci. & Appl.13, 84 (2024) on Pith
  16. [16] C. Riek, D. V. Seletskiy, A. S. Moskalenko,et al., “Direct sampling of electric-field vacuum fluctuations,” Science350, 420–423 (2015) on Pith
  17. [17] G. Gallot and D. Grischkowsky, “Electro-optic detection of terahertz radiation,” J. Opt. Soc. Am. B16, 1204–1212 (1999) on Pith
  18. [18] C. Beckh, P . Sulzer, N. Fritzsche,et al., “Analysis of subcycle electro- optic sampling without background,” J. Infrared, Millimeter, Terahertz Waves42, 701–714 (2021) on Pith
  19. [19] M. Porer, J.-M. Ménard, and R. Huber, “Shot noise reduced terahertz detection via spectrally postfiltered electro-optic sampling,” Opt. Lett. 39, 2435–2438 (2014) on Pith
  20. [20] Z. Jiang, F . G. Sun, Q. Chen, and X.-C. Zhang, “Electro-optic sampling near zero optical transmission point,” Appl. Phys. Lett.74, 1191–1193 (1999) on Pith
show 17 more
  1. [21] S.-X. Xu and H. Cai, “A theoretical and experimental research on terahertz electro-optic sampling at near-zero optical transmission point,” Chin. Phys. Lett.25, 152–155 (2008) on Pith
  2. [22] F . D. J. Brunner, J. A. Johnson, S. Grübel,et al., “Distortion-free en- hancement of terahertz signals measured by electro-optic sampling. I. Theory,” J. Opt. Soc. Am. B31, 904–910 (2014) on Pith
  3. [23] J. A. Johnson, F . D. J. Brunner, S. Grübel,et al., “Distortion-free en- hancement of terahertz signals measured by electro-optic sampling. II. Experiment,” J. Opt. Soc. Am. B31, 1035–1040 (2014) on Pith
  4. [24] X. Pan, Y . Cai, X. Zeng,et al., “Modified THz electro-optic sampling for high optical modulation depth, large dynamical range, and low background noises,” Opt. Lett.39, 3778–3781 (2014) on Pith
  5. [25] H. Kato, H. Kitahara, D. Goto,et al., “Enhancement of THz EO sampling signal by polarization filtering,” in2018 43rd International Conference on Infrared, Millimeter, and T erahertz Waves (IRMMW-THz),(IEEE, 2018) on Pith
  6. [26] C. J. Stromberg and E. J. Heilweil, “Practical considerations for the amplification of electro-optically detected THz signals,” J. Opt. Soc. Am. B41, 2350–2357 (2024) on Pith
  7. [27] B. P . Abbottet al., “Observation of gravitational waves from a binary black hole merger,” Phys. Rev. Lett.116, 061102 (2016) on Pith
  8. [28] T. Tomberg, A. Muraviev, Q. Ru, and K. L. Vodopyanov, “Background- free broadband absorption spectroscopy based on interferometric sup- pression with a sign-inverted waveform,” Optica6, 147–151 (2019) on Pith
  9. [29] W. Song, D. Okazaki, I. Morichika, and S. Ashihara, “Broadband background-free vibrational spectroscopy using a mode-locked Cr:ZnS laser,” Opt. Express30, 38674–38683 (2022) on Pith
  10. [30] B. Clough, D. H. Hurley, P . Han,et al., “Detection of terahertz pulses using a modified Sagnac interferometer,” Sens. Imaging: An Int. J.10, 55–62 (2009) on Pith
  11. [31] A. Ibrahim, D. Férachou, G. Sharma,et al., “Ultra-high dynamic range electro-optic sampling for detecting millimeter and sub-millimeter radia- tion,” Sci. Reports6, 23107 (2016) on Pith
  12. [32] I. Wilke, J. Monahan, S. Toroghi,et al., “Thin-film lithium niobate electro- optic terahertz wave detector,” Sci. Reports14, 4822 (2024) on Pith
  13. [33] S. Casalbuoni, H. Schlarb, B. Schmidt,et al., “Numerical studies on the electro-optic detection of femtosecond electron bunches,” Phys. Rev. Special Top. Beams11, 072802 (2008) on Pith
  14. [34] D. T. F . Marple, “Refractive index of ZnSe, ZnTe, and CdTe,” J. Appl. Phys.35, 539–542 (1964) on Pith
  15. [35] R. S. Weis and T. K. Gaylord, “Lithium niobate: Summary of physical properties and crystal structure,” Appl. Phys. A37, 191–203 (1985) on Pith
  16. [36] C. Wang, M. Zhang, X. Chen,et al., “Integrated lithium niobate electro- optic modulators operating at CMOS-compatible voltages,” Nature562, 101–104 (2018) on Pith
  17. [37] M. Lenz and P . Musumeci, “Single-shot electro-optic sampling with arbitrary terahertz polarization,” Photonics Res.13, 1736–1746 (2025) on Pith