Pith. sign in

REVIEW 2 cited by

XMM-Newton and Chandra Cross Calibration Using HIFLUGCS Galaxy Clusters: Systematic Temperature Differences and Cosmological Impact

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1404.7130 v2 pith:2OODGJK6 submitted 2014-04-28 astro-ph.CO astro-ph.HEastro-ph.IM

classification astro-ph.COastro-ph.HEastro-ph.IM
keywords clusterscosmologicaltemperaturexmm-newtonchandrax-raycalibrationcluster
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Cosmological constraints from clusters rely on accurate gravitational mass estimates, which strongly depend on cluster gas temperature measurements. Therefore, systematic calibration differences may result in biased, instrument-dependent cosmological constraints. This is of special interest in the light of the tension between the Planck results of the primary temperature anisotropies of the CMB and Sunyaev-Zel'dovich plus X-ray cluster counts analyses. We quantify in detail the systematics and uncertainties of the cross-calibration of the effective area between five X-ray instruments, EPIC-MOS1/MOS2/PN onboard XMM-Newton and ACIS-I/S onboard Chandra, and the influence on temperature measurements. Furthermore, we assess the impact of the cross calibration uncertainties on cosmology. Using the HIFLUGCS sample, consisting of the 64 X-ray brightest galaxy clusters, we constrain the ICM temperatures through spectral fitting in the same, mostly isothermal, regions and compare them. Our work is an extension to a previous one using X-ray clusters by the IACHEC. Performing spectral fitting in the full energy band we find that best-fit temperatures determined with XMM-Newton/EPIC are significantly lower than Chandra/ACIS temperatures. We demonstrate that effects like multitemperature structure and different relative sensitivities of the instruments at certain energy bands cannot explain the observed differences. We conclude that using XMM-Newton/EPIC, instead of Chandra/ACIS to derive full energy band temperature profiles for cluster mass determination results in an 8% shift towards lower OmegaM values and <1% shift towards higher sigma8 values in a cosmological analysis of a complete sample of galaxy clusters. Such a shift is insufficient to significantly alleviate the tension between Planck CMB anisotropies and SZ plus XMM-Newton cosmological constraints.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Average soft X-ray surface brightness profile of massive galaxy clusters in Magneticum simulations

    astro-ph.CO 2026-08 conditional novelty 6.0 of 10

    Magneticum simulations reproduce the eROSITA stacked soft X-ray surface brightness profile of massive clusters out to about 3 R500, with a central difference attributed to AGN feedback.

  2. Correcting the hydrostatic mass for non-thermal gas motions: a comparison of two approaches

    astro-ph.CO 2026-07 unverdicted novelty 4.0 of 10

    The two correction approaches differ in their radial dependence in 3D but agree to within a few percent in projected observations, with the non-thermal pressure fraction underestimated by a factor of about 2.

Pith tools