REVIEW 4 major objections 2 minor 71 references
Hybrid(Transformer+CNN)-based Polyp Segmentation
T0 review · 4 major / 2 minor · reviewed 2026-08-05 · deepseek-v4-flash
Pith's one-line read This paper claims a hybrid Swin Transformer-CNN network outperforms existing polyp-segmentation models, lifting recall to 0.9555 and accuracy to 0.9849 on Kvasir-SEG.
desk verdict Test-set early stopping and a missing architecture description leave the SOTA claim unsupported; the paper is a clear but overclaimed incremental baseline. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The central object is the staged hybrid encoder-decoder: a Swin Transformer backbone emitting feature maps $F_1,\dots,F_4$ at resolutions $H/4$, $H/8$, $H/16$, $H/32$ with channel depths $C,2C,4C,8C$; a decoder $D_4,\dots,D_1$ that refines each level with a $3\times3$ conv-BN-ReLU block, bilinear 2x upsampling, and concatenative skip connections; and a final $1\times1$ convolution plus bilinear resize to full resolution. The paper names adaptive fusion modules, context-preserving skip connections, and a cross-attention bridge as the three innovations that balance transformer and CNN features. The mechanism's job is to join long-range global context with pixel-level boundary detail, which is
What would settle it
Rerun the same 900/100 Kvasir-SEG training recipe but stop learning based on a held-out validation set rather than the test set, then recompute recall and accuracy on the test images. If recall falls below DUCK-Net's 0.9379 or accuracy below 0.9842, the paper's central superiority claim fails; a quicker check is to compute the missing mDice/mIoU cells in Table 2 and see whether they also exceed DUCK-Net.
Extended reading notes
Core claim
Central claim: a hybrid (Transformer + CNN) architecture can outperform established polyp-segmentation models on the Kvasir-SEG benchmark. The paper reports recall 0.9555 and accuracy 0.9849, improving on DUCK-Net's recall (0.9379) and accuracy (0.9842), and states that this comes with the highest FPS among the models compared. The design pairs a pre-trained Swin Transformer encoder—which produces four hierarchical feature maps from $H/4$ to $H/32$ using shifted-window self-attention—with a CNN decoder that restores spatial detail through conv-BN-ReLU blocks, bilinear upsampling, and concatenative skip connections. The author's explanation is that this division of labor handles both ill-defi
Load-bearing premise
The reported recall and accuracy gains would still appear on genuinely unseen colonoscopy images, even though training was stopped by watching the Dice score on the same test set.
Editorial extensions
If this is right
- On Kvasir-SEG, the hybrid model would detect a larger share of polyp pixels than DUCK-Net (recall 0.9555 vs 0.9379), raising the chance that small or flat lesions are visible to the endoscopist.
- The reported frames-per-second means the accuracy gain would not necessarily block live 1080p/30fps use, making the model a candidate for real-time assistance.
- If the multi-dataset tests on CVC-ClinicDB, ETIS, CVC-ColonDB, and Endotect are as claimed, the design transfers across different scopes, resolutions, and polyp appearances.
- The same encoder-decoder split—transformer for context, CNN for detail—would apply to other medical segmentation problems where boundaries are weak.
Reading between the lines
- The paper's own Table 2 leaves mDice and mIoU blank for the hybrid model while DUCK-Net reports 0.9051 mIoU; filling those cells with the same test set would show whether the 'superior performance' claim is purely a recall-and-accuracy result or holds across overlap metrics.
- The abstract credits boundary-aware attention, but Section 3's equations specify only conv-BN-ReLU blocks and bilinear upsampling; an ablation that turns off the cross-attention bridge would reveal whether the recall gain actually comes from explicit boundary modeling or from the multi-scale skip connections alone.
- A natural extension is to run the same 900/100 Kvasir-SEG split with early stopping on a validation split and to publish per-dataset results for CVC-ClinicDB, ETIS, CVC-ColonDB, and Endotect; that would separate architecture gains from test-set tuning.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper proposes a hybrid Swin-Transformer/CNN architecture for polyp segmentation and reports results on Kvasir-SEG, claiming superior performance over state-of-the-art methods, including DUCK-Net. The architecture is a standard encoder–decoder with skip connections, and the reported evaluation uses a 900/100 train/test split. The central claims are that the model improves recall and accuracy over DUCK-Net and that it is robust to endoscopic artifacts and ill-defined polyp boundaries.
Significance. If the reported results were obtained under a sound protocol and the architecture matched the described innovations, the work could be of interest for real-time polyp segmentation. The paper is clearly written and the architecture is easy to follow. However, the evaluation protocol is flawed, the reported metrics do not support the superiority claim even at face value, and several abstract-level claims are not backed by experiments or by the described architecture. The current manuscript does not provide reliable evidence for its central claim.
major comments (4)
- [Section 4 and §5.1] The early-stopping criterion is explicitly computed on the test set: 'inspecting the Dice score on the test set after every epoch' and 'cross-validation was applied solely on the test set within the Kvasir dataset.' This means the reported test metrics are not unbiased estimates of generalization; they are selected using the same data on which they are reported. Any comparison with DUCK-Net's published numbers is therefore invalid unless DUCK-Net was selected under the same protocol. A separate validation split is required before any claim of superiority can be made.
- [Table 2 and §6] Even accepting the table at face value, the model is not superior: F1 is 0.9499 versus DUCK-Net's 0.9502, precision is 0.9422 versus 0.9628, and mDice/mIoU for the proposed model are missing (dash). The only claimed gains are recall and accuracy, and the recall value is inconsistent between the abstract (0.9555) and Table 2 (0.955). To support the central claim, the authors need to report the complete metric set, ideally with confidence intervals, and compare all models under the same evaluation protocol.
- [Abstract versus §3] The abstract attributes the performance to 'boundary-aware attention mechanisms' and robustness to 'specular highlights, motion blur, and fluid occlusions,' but the architecture described in §3.1–3.3 is a standard Swin encoder with CNN decoder blocks and concatenation skip connections; there is no boundary-aware attention module, and no artifact-robustness experiments are reported anywhere in the manuscript. These claims are therefore unsupported by the described method and experiments.
- [§5.1 and §7] The paper states that the model was further tested on CVC-ClinicDB, ETIS, CVC-ColonDB, and Endotect, and the conclusion claims SOTA performance across DSC, IoU, precision, recall, F2, and FPS. However, no results for any external dataset are presented, and Table 2 does not report mDice, mIoU, F2, or FPS for the proposed model. These claims should be substantiated or removed.
minor comments (2)
- [Throughout] There are typos and formatting issues: 'Kavasir-SEG' should be 'Kvasir-SEG', '33 convolutional' should be '3×3 convolutional', 'coscusative performance' appears to be a typo, and Figure 4's caption says 'fifty epochs' while Section 4 states training ran for 100 epochs.
- [References] The reference list contains entries that appear to be irrelevant to the manuscript (e.g., [4], [15], [46], [51]) and some citations are not properly matched to the text. The references should be pruned and verified.
Circularity Check
Test-set early stopping turns the reported recall/accuracy into fitted values, so the SOTA claim is partially circular.
-
fitted input called prediction
[Section 4 (Implementation details), early-stopping paragraph; Section 5.1; Table 2]
"In an effort to avoid overfitting, an early stopping condition was used, inspecting the Dice score on the test set after every epoch. Training was stopped if no progress had been made in the last 37 epochs, which happened at epoch 63."
The stopping epoch was selected by monitoring Dice on the Kvasir-SEG test set. The same test set then produced the Recall=0.9555 and Accuracy=0.9849 in Table 2, which the abstract highlights as 'improved by 1.76%... 0.07%' over DUCK-Net. Section 5.1 reinforces: 'cross-validation was applied solely on the test set within the Kvasir dataset.' Thus the headline metrics are not out-of-sample predictions; they are outcomes of a test-set selection procedure. Comparing them to DUCK-Net's independently evaluated published numbers is invalid, and the claimed gains (recall, accuracy) are precisely the metrics this protocol can inflate. The central 'superior performance' claim reduces to a test-set fit rather than an independent prediction.
full rationale
This paper has no theoretical derivation that could be self-definitional; it is an empirical architecture paper. The architecture (Swin encoder + CNN decoder with concatenation and upsampling) is presented directly, with no imported uniqueness claim and no self-citations, so patterns 3-5 do not apply. The one load-bearing circularity is in the evaluation protocol: Section 4 states that early stopping inspected the Dice score on the test set after every epoch and stopped at epoch 63, and Section 5.1 says cross-validation was applied solely on the test set within Kvasir. The same test set then supplies the Table 2 metrics, including Recall 0.9555 and Accuracy 0.9849, which the abstract promotes as SOTA improvements over DUCK-Net. Those numbers are therefore selected values, not independent generalization estimates, and the comparison to DUCK-Net's published numbers is invalid under this protocol. This is a genuine 'fitted input called prediction' pattern and it sits at the center of the paper's superiority claim, so the circularity score is 6. Separately, the abstract's claims of boundary-aware attention and artifact resilience are not supported by Section 3 or by any artifact-ablation experiment, but that is a missing-support/correctness issue, not circularity, and I do not count it in the score.
Assumptions & free parameters
free parameters (1)
- Training hyperparameters (learning rate, weight decay, batch size, input size, early stopping patience) =
1e-4, 1e-4, 8, 352x352, 37 epochs
assumptions (2)
- domain assumption Kvasir-SEG 900/100 split is a valid benchmark for polyp segmentation
- ad hoc to paper Using the test set for early stopping yields unbiased final metrics
Cite this review
Pith. "Pith review of Hybrid(Transformer+CNN)-based Polyp Segmentation." pith.science (2026). https://pith.science/paper/337YT7D4
@misc{pith2026250809189,
author = {Pith},
title = {Pith review of: Hybrid(Transformer+CNN)-based Polyp Segmentation},
year = {2026},
howpublished = {\url{https://pith.science/paper/337YT7D4}},
note = {Machine review of arXiv:2508.09189}
}
read the original abstract
Colonoscopy is still the main method of detection and segmentation of colonic polyps, and recent advancements in deep learning networks such as U-Net, ResUNet, Swin-UNet, and PraNet have made outstanding performance in polyp segmentation. Yet, the problem is extremely challenging due to high variation in size, shape, endoscopy types, lighting, imaging protocols, and ill-defined boundaries (fluid, folds) of the polyps, rendering accurate segmentation a challenging and problematic task. To address these critical challenges in polyp segmentation, we introduce a hybrid (Transformer + CNN) model that is crafted to enhance robustness against evolving polyp characteristics. Our hybrid architecture demonstrates superior performance over existing solutions, particularly in addressing two critical challenges: (1) accurate segmentation of polyps with ill-defined margins through boundary-aware attention mechanisms, and (2) robust feature extraction in the presence of common endoscopic artifacts, including specular highlights, motion blur, and fluid occlusions. Quantitative evaluations reveal significant improvements in segmentation accuracy (Recall improved by 1.76%, i.e., 0.9555, accuracy improved by 0.07%, i.e., 0.9849) and artifact resilience compared to state-of-the-art polyp segmentation methods.
Figures
Reference graph
Works this paper leans on
-
[1]
Edd2020: A comprehensive dataset for en- doscopic artifact detection
Sharib Ali et al. Edd2020: A comprehensive dataset for en- doscopic artifact detection. Endoscopy, 52:S1–S7, 2020. 4
work page 2020
-
[2]
Polypgen: A multi-center polyp detection and segmentation dataset
Sharib Ali et al. Polypgen: A multi-center polyp detection and segmentation dataset. Nature Scientific Data, 9(1):1–12,
-
[3]
Sharib Ali, Feng Zhou, Barbara Braden, Adam Bailey, Suhui Yang, Guangtao Cheng, Pengyi Zhang, Xiao Li, Max Kayser, Roger Soberanis-Mukul, et al. Automatic detec- 5 Table 2: Performance Comparison of Polyp Segmentation Models in Kavasir-SEG dataset Model F1 Score mDice mIoU Precision Recall Accuracy U-Net† [47] 0.8655 – 0.7629 0.8593 0.8718 - ResUNet [68] ...
work page 2016
-
[4]
Artificial intelligence in knee arthroplasty: Current concept of the available clinical applications
Christophe Batailler, Jeremy Shatrov, Emmanuel Sappey- Marinier, Elvire Servien, Sebastien Parratte, and S ´ebastien Lustig. Artificial intelligence in knee arthroplasty: Current concept of the available clinical applications. Arthroplasty, 4:1–16, 2022
work page 2022
-
[5]
To- wards automatic polyp detection with a polyp appearance model
Jorge Bernal, F Javier S ´anchez, Gloria Fern´andez-Esparrach, Debora Gil, Cristina Rodr´ıguez, and Fernando Vilarino. To- wards automatic polyp detection with a polyp appearance model. Pattern Recognition, 48(11):3166–3182, 2015. 4
work page 2015
-
[6]
Jorge Bernal, Francisco J. Sanchez, G. Fernandez-Esparrach, D. Gil, C. Rodrıguez, and F. Vilarino. Wm-dova maps for accurate polyp highlighting in colonoscopy: Validation vs. saliency maps from physicians. Computers in Medical Imag- ing and Graphics, 43:99–111, 2015
work page 2015
-
[7]
Wm- dova maps for accurate polyp highlighting in colonoscopy
Jorge Bernal, Javier S ´anchez, and Fernando Vilarino. Wm- dova maps for accurate polyp highlighting in colonoscopy. Medical Image Analysis, 17(7):703–718, 2013. 4
work page 2013
-
[8]
Comparative validation of polyp detection methods in video colonoscopy
Jorge Bernal, Nima Tajkbaksh, Francisco Javier S ´anchez, Bogdan J Matuszewski, Hao Chen, Lequan Yu, Quentin Angermann, Olivier Romain, Bjørn Rustad, Ilangko Balas- ingham, et al. Comparative validation of polyp detection methods in video colonoscopy. IEEE Transactions on Medi- cal Imaging, 36(2):496–507, 2017. 4
work page 2017
Show all 71 references
-
[9]
Un- derstanding robustness of transformers for image classifica- tion
Srinadh Bhojanapalli, Ayan Chakrabarti, Daniel Glasner, Daliang Li, Thomas Unterthiner, and Andreas Veit. Un- derstanding robustness of transformers for image classifica- tion. In Proceedings of the IEEE International Conference on Computer Vision (ICCV), pages 10211–10221, 2021
2021
-
[10]
Hyperkvasir: A comprehensive multi- class image and video dataset for gastrointestinal endoscopy
Rune Borgli et al. Hyperkvasir: A comprehensive multi- class image and video dataset for gastrointestinal endoscopy. Scientific Data, 7(1):1–14, 2020. 4
2020
-
[11]
Swin-unet: Unet-like pure transformer for medical image segmentation
Hu Cao, Yueyue Wang, Joy Chen, Dongsheng Jiang, Xi- aopeng Zhang, Qi Tian, and Manning Wang. Swin-unet: Unet-like pure transformer for medical image segmentation. arXiv preprint arXiv:2105.05537, 2021. 3
2021 arXiv
-
[12]
Yuille, and Yuyin Zhou
Jieneng Chen, Yongyi Lu, Qihang Yu, Xiangde Luo, Ehsan Adeli, Yan Wang, Le Lu, Alan L. Yuille, and Yuyin Zhou. Transunet: Transformers make strong encoders for medi- cal image segmentation. arXiv preprint arXiv:2102.04306,
-
[13]
Polyp-pvt: Polyp segmentation with pyramid vision transformers
Bing Dong, Wenhai Wang, Deng-Ping Fan, Jian Li, Huazhu Fu, and Ling Shao. Polyp-pvt: Polyp segmentation with pyramid vision transformers. ArXiv preprint, 2021. 3
2021
-
[14]
An image is worth 16x16 words: Transformers for image recognition at scale
Alexey Dosovitskiy, Lucas Beyer, Alexander Kolesnikov, et al. An image is worth 16x16 words: Transformers for image recognition at scale. ArXiv preprint, 2021. 3
2021
-
[15]
Espinosa, Gaston A
Marco G. Espinosa, Gaston A. Otarola, Jerry C. Hu, and Kyr- iacos A. Athanasiou. Cartilage assessment requires a surface characterization protocol: Roughness, friction, and function. Tissue Engineering Part C: Methods, 27:276–286, 2021
2021
-
[16]
Sun-seg: A large-scale dataset for sur- gical scene segmentation
Deng-Ping Fan et al. Sun-seg: A large-scale dataset for sur- gical scene segmentation. IEEE Transactions on Medical Imaging, 41(3):786–796, 2022. 4
2022
-
[17]
Pranet: Parallel reverse attention network for polyp segmentation
Deng-Ping Fan, Ge-Peng Ji, Tao Zhou, Geng Chen, Huazhu Fu, Jianbing Shen, and Ling Shao. Pranet: Parallel reverse attention network for polyp segmentation. In International Conference on Medical Image Computing and Computer- Assisted Intervention, pages 263–273. Springer, 2020. 2, 6
2020
-
[18]
Roth, and Daguang Xu
Ali Hatamizadeh, Vishwesh Nath, Yucheng Tang, Dong Yang, Holger R. Roth, and Daguang Xu. Swin unetr: Swin transformers for semantic segmentation of brain tumors in mri images. In International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI) , ...
2022
-
[19]
Deep residual learning for image recognition
Kaiming He, Xiangyu Zhang, Shaoqing Ren, and Jian Sun. Deep residual learning for image recognition. In Proceed- ings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), pages 770–778, 2016. 2
2016
-
[20]
Kvasir-capsule: A video capsule en- doscopy dataset
Steven A Hicks et al. Kvasir-capsule: A video capsule en- doscopy dataset. Nature Scientific Reports, 11:15671, 2021. 4
2021
-
[21]
Piccolo dataset for endoscopic polyp segmentation
Alejandro Jaqu ´ez et al. Piccolo dataset for endoscopic polyp segmentation. Medical Physics, 47:e123–e124, 2020. 4
2020
-
[22]
Real- time polyp detection, localization and segmentation in colonoscopy using deep learning
Debesh Jha, Safdar Ali, Nikhil Kumar Tomar, et al. Real- time polyp detection, localization and segmentation in colonoscopy using deep learning. IEEE Access, 9:40496– 40510, 2021. 2
2021
-
[23]
Johansen, Dag Johansen, Jens Rittscher, Michael A
Debesh Jha, Sharib Ali, Naman Kumar Tomar, H ˚avard D. Johansen, Dag Johansen, Jens Rittscher, Michael A. Riegler, and P˚al Halvorsen. Doubleu-net: A deep convolutional neu- ral network for medical image segmentation. 2020 IEEE 33rd International Symposium on Computer-Based Me...
2020
-
[24]
Smedsrud, Daniel Johansen, et al
Debesh Jha, Pia H. Smedsrud, Daniel Johansen, et al. A comprehensive study on colorectal polyp segmentation with resunet++, conditional random field and test-time augmenta- tion. IEEE Journal of Biomedical and Health Informatics , 25:2029–2040, 2021. 2
-
[25]
Smedsrud, Michael A
Debesh Jha, Pia H. Smedsrud, Michael A. Riegler, et al. Kvasir-seg: a segmented polyp dataset. In Interna- tional Conference on Multimedia Modeling, pages 451–462. Springer, Cham, 2020. 2
2020
-
[26]
Kvasir-seg: A segmented polyp dataset
Debesh Jha, Pia H Smedsrud, Michael A Riegler, P ˚al Halvorsen, Thomas de Lange, Dag Johansen, and H ˚avard D Johansen. Kvasir-seg: A segmented polyp dataset. arXiv preprint arXiv:1911.07069, 2019. 4
1911 arXiv
-
[27]
Smedsrud, Michael A
Debesh Jha, Pia H. Smedsrud, Michael A. Riegler, Daniel T. Johansen de Lange, P˚al Halvorsen, and H˚avard D. Johansen. Resunet++: an advanced architecture for medical image seg- mentation. In Proceedings of IEEE International Symposium on Multimedia (ISM), pages 225–255, 2019. 2, 6
2019
-
[28]
Nanonet: real-time polyp segmentation in video capsule endoscopy and colonoscopy
Debesh Jha, Nikhil Kumar Tomar, Safdar Ali, et al. Nanonet: real-time polyp segmentation in video capsule endoscopy and colonoscopy. InProceedings of IEEE International Sym- posium on Computer-Based Medical Systems (CBMS), pages 37–43, 2021. 2, 3
2021
-
[29]
Deep learning-based detection of polyps in colonoscopy
Tae Kyoung Kim, Chan Ho Park, Chang Min Lee, Min Ju Kang, and Hyun Gun Kim. Deep learning-based detection of polyps in colonoscopy. Scientific Reports, 10(1):1–9, 2020. 4
2020
-
[30]
Li-segpnet: A lightweight pyramid network for real-time polyp segmentation
Yuan Li, Hao Chen, Manning Wang, and Xiaolong Zhang. Li-segpnet: A lightweight pyramid network for real-time polyp segmentation. IEEE Transactions on Medical Imag- ing, 41(5):1124–1135, 2022. 6
2022
-
[31]
Sun: A large-scale dataset for surgical understanding
Daochang Liu, Ziyu Jiang, Yizhou Wang, Qiang Wang, Fei Wang, Ziyu Li, and Changhu Wang. Sun: A large-scale dataset for surgical understanding. IEEE Transactions on Medical Robotics and Bionics, 2(1):41–48, 2020. 4
2020
-
[32]
Cp-child: A pediatric colon polyp dataset
Jiang Liu et al. Cp-child: A pediatric colon polyp dataset. Scientific Data, 7(1):1–8, 2020. 4
2020
-
[33]
Ddanet: Dual decoder attention network for automatic polyp segmentation
Jiang Liu, Tengfei Song, Meng Li, Linlin Qiao, Yitian Zhao, and Yunde Jia. Ddanet: Dual decoder attention network for automatic polyp segmentation. Pattern Recognition , 122:108318, 2022. 2
2022
-
[34]
Ld polyp video: A large-scale colonoscopy video dataset
Xiaoyu Liu et al. Ld polyp video: A large-scale colonoscopy video dataset. Medical Image Analysis, 70:101987, 2021. 4
2021
-
[35]
Swin trans- former: Hierarchical vision transformer using shifted win- dows
Ze Liu, Yutong Lin, Yue Cao, Han Hu, Yixuan Wei, Zheng Zhang, Stephen Lin, and Baining Guo. Swin trans- former: Hierarchical vision transformer using shifted win- dows. ICCV, 2021
2021
-
[36]
Fully convolutional networks for semantic segmentation
Jonathan Long, Evan Shelhamer, and Trevor Darrell. Fully convolutional networks for semantic segmentation. In Pro- ceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), pages 3431–3440, 2015. 2
2015
-
[37]
Decoupled weight de- cay regularization
Ilya Loshchilov and Frank Hutter. Decoupled weight de- cay regularization. In International Conference on Learning Representations (ICLR), 2019
2019
-
[38]
Mamonov, Isabel N
Alexander V . Mamonov, Isabel N. Figueiredo, Pedro N. Figueiredo, and Yu-Hsiang R. Tsai. Automated polyp de- tection in colon capsule endoscopy. IEEE Transactions on Medical Imaging, 33:1488–1502, 2014. 2
2014
-
[39]
Matsuda, A
T. Matsuda, A. Ono, M. Sekiguchi, T. Fujii, and Y . Saito. Advances in image enhancement in colonoscopy for detec- tion of adenomas. Nature Reviews Gastroenterology & Hep- atology, 14:305–314, 2017. 1
2017
-
[40]
Understanding your diagno- sis: Colonoscopy
The American Cancer Society Medical and Edito- rial Content Team. Understanding your diagno- sis: Colonoscopy. https://www.cancer.org/ treatment/understanding-your-diagnosis/ tests/endoscopy/colonoscopy.html, n.d. Accessed: YYYY-MM-DD. 1
-
[41]
A deep learning method for early detection of dia- betic foot using decision fusion and thermal images
Khairul Munadi, Khairunnisa Saddami, Masayu Oktiana, et al. A deep learning method for early detection of dia- betic foot using decision fusion and thermal images. Applied Sciences, 12:7524–7545, 2022
2022
-
[42]
Cancer stat facts: Colorectal cancer
NIH. Cancer stat facts: Colorectal cancer. http: //www.seer.cancer.gov/statfacts/html/ colorect.html, n.d. Accessed: YYYY-MM-DD. 1
-
[43]
Uacanet: Unified adaptive context-aware network for polyp segmentation
Seung-Jun Oh, Hyun Kim, Sang-Hoon Oh, and Seung-Won Lee. Uacanet: Unified adaptive context-aware network for polyp segmentation. In Proceedings of the 29th ACM In- ternational Conference on Multimedia , pages 1762–1770. ACM, 2021. 2
2021
-
[44]
Deep learning and hand-crafted fea- tures for automatic polyp detection
Konstantin Pogorelov, Klaus R Randel, Carsten Griwodz, Sigrun L Eskeland, Thomas de Lange, Dag Johansen, Con- cetto Spampinato, Duc-Tien Dang-Nguyen, Mathias Lux, Peter T Schmidt, et al. Deep learning and hand-crafted fea- tures for automatic polyp detection. In IEEE Internati...
-
[45]
Nbi and wl ucdb databases for computer-assisted detection of ulcerative lesions
Sara Reis, Guilherme Macedo, Cl ´audia Bahia, and Miguel T Coimbra. Nbi and wl ucdb databases for computer-assisted detection of ulcerative lesions. IEEE Access , 7:74293– 74302, 2019. 4
2019
-
[46]
Rodr ´ıguez-Merch´an and Pilar G ´omez-Cardero
Eduardo C. Rodr ´ıguez-Merch´an and Pilar G ´omez-Cardero. The outerbridge classification predicts the need for patellar resurfacing in tka. Clinical Orthopaedics and Related Re- search, 468:1254–1257, 2010
2010
-
[47]
U-net: Convolutional networks for biomedical image segmentation
Olaf Ronneberger, Philipp Fischer, and Thomas Brox. U-net: Convolutional networks for biomedical image segmentation. In Medical Image Computing and Computer-Assisted Inter- vention (MICCAI), volume 9351, pages 234–241, 2015. 2, 6
2015
-
[48]
Toward embedded detection of polyps in wce images for early diagnosis of colorectal can- cer
Jo ˜ao Silva, Aymeric Histace, Olivier Romain, Xavier Dray, and Bertrand Granado. Toward embedded detection of polyps in wce images for early diagnosis of colorectal can- cer. In IEEE International Conference on Robotics and Biomimetics, pages 1790–1795, 2014. 4
2014
-
[49]
Toward embedded detection of polyps in wce images for early diagnosis of colorectal can- cer
Jorge Silva, Aymeric Histace, Olivier Romain, Xavier Dray, and Bertrand Granado. Toward embedded detection of polyps in wce images for early diagnosis of colorectal can- cer. International Journal of Computer Assisted Radiology and Surgery, 9:283–293, 2014
2014
-
[50]
Very deep con- volutional networks for large-scale image recognition
Karen Simonyan and Andrew Zisserman. Very deep con- volutional networks for large-scale image recognition. In In- ternational Conference on Learning Representations (ICLR),
-
[51]
Colleen Slattery and Charles Y . Kweon. Classifications in brief: Outerbridge classification of chondral lesions.Clinical Orthopaedics and Related Research, 476:2101–2104, 2018
2018
-
[52]
Kvasir-capsule, a video capsule endoscopy dataset
Pia H Smedsrud, Vajira Thambawita, Steven A Hicks, H˚avard L Gjestang, Oda O Nedrejord, Espen Næss, Rune Borgli, Debesh Jha, Torunn Berstad, Sigrun L Eskeland, et al. Kvasir-capsule, a video capsule endoscopy dataset. arXiv preprint arXiv:1907.05719, 2019. 4
1907 arXiv
-
[53]
Gurudu, and Jianming Liang
Nima Tajbakhsh, Suryakanth R. Gurudu, and Jianming Liang. Automated polyp detection in colonoscopy videos using shape and context information. IEEE Transactions on Medical Imaging, 35:630–644, 2015
2015
-
[54]
Automated polyp detection in colonoscopy videos using shape and context information
Nima Tajbakhsh, Suryakanth R Gurudu, and Jianming Liang. Automated polyp detection in colonoscopy videos using shape and context information. IEEE Transactions on Medical Imaging, 35(2):630–644, 2016. 4
2016
-
[55]
Vajira Thambawita, Steven Hicks, P ˚al Halvorsen, and Michael A. Riegler. Pyramid-focus-augmentation: Medical image segmentation with step-wise focus. ArXiv preprint,
-
[56]
Atten- tion is all you need
Ashish Vaswani, Noam Shazeer, Niki Parmar, et al. Atten- tion is all you need. In Advances in Neural Information Pro- cessing Systems (NeurIPS), pages 6000–6010, 2017. 3
2017
-
[57]
Sanchez, et al
David Vazquez, Jorge Bernal, Francisco J. Sanchez, et al. A benchmark for endoluminal scene segmentation of colonoscopy images. Journal of Healthcare Engineering , 2017:1–9, 2017
2017
-
[58]
Vezakis, Konstantinos Georgas, Dimitrios Fo- tiadis, and George K
Ioannis A. Vezakis, Konstantinos Georgas, Dimitrios Fo- tiadis, and George K. Matsopoulos. Effisegnet: Gas- trointestinal polyp segmentation through a pre-trained efficientnet-based network with a simplified decoder, 2024
2024
-
[59]
Duck-net: Dense u-shaped convolutional ker- nel network for polyp segmentation
Cheng Wang, Zheng Li, Xiaolong Zhang, Minghui Qiu, and Guang Yang. Duck-net: Dense u-shaped convolutional ker- nel network for polyp segmentation. IEEE Transactions on Medical Imaging, 42(4):1029–1040, 2023. 6
2023
-
[60]
Nanonet: Real-time polyp segmentation with ultra-lightweight models for edge devices
Cheng Wang, Zheng Li, Xiaolong Zhang, Minghui Qiu, and Guang Yang. Nanonet: Real-time polyp segmentation with ultra-lightweight models for edge devices. In IEEE In- ternational Conference on Bioinformatics and Biomedicine (BIBM), pages 1234–1241. IEEE, 2023. 3
2023
-
[61]
Pvt v2: Improved baselines with pyramid vision transformer
Wenhai Wang, Enze Xie, Xiang Li, et al. Pvt v2: Improved baselines with pyramid vision transformer. Computer Vision and Image Understanding (CVIU), 8:415–424, 2021. 3
2021
-
[62]
A versatile back- bone for dense prediction without convolutions
Wenhai Wang, Enze Xie, Xiang Li, et al. A versatile back- bone for dense prediction without convolutions. In Proceed- ings of the IEEE/CVF International Conference on Com- puter Vision (ICCV), pages 548–558, 2021. 3
2021
-
[63]
Msrfe-net: Multi-scale residual feature enhancement network for polyp segmentation
Yujia Wang, Yu Zhang, Jindong Tian, Cheng Zhong, Yong- dong Zhang, and Yiyan Shi. Msrfe-net: Multi-scale residual feature enhancement network for polyp segmentation. IEEE Transactions on Medical Imaging, 41(12):3721–3734, 2022. 2
2022
-
[64]
Williams, Domenico Borroni, Renqiang Liu, et al
Ben M. Williams, Domenico Borroni, Renqiang Liu, et al. An artificial intelligence-based deep learning algorithm for the diagnosis of diabetic neuropathy using corneal confo- cal microscopy: A development and validation study. Di- abetologia, 63:419–430, 2020
2020
-
[65]
Alvarez, and Ping Luo
Enze Xie, Wenhai Wang, Zhiding Yu, Anima Anandkumar, Jose M. Alvarez, and Ping Luo. Segformer: Simple and effi- cient design for semantic segmentation with transformers. In Proceedings of the 35th Conference on Neural Information Processing Systems (NeurIPS), 2021
2021
-
[66]
Colonformer: An efficient transformer based method for colon polyp segmentation
Wei Zhang, Qiang Li, Zhou Yu, Yang Chen, and Jingdong Wang. Colonformer: An efficient transformer based method for colon polyp segmentation. IEEE Journal of Biomedical and Health Informatics, 26(8):3970–3980, 2022. 6
2022
-
[67]
Fcb- former: A fully convolutional bridge transformer with pyra- mid squeeze-excitation for colonoscopy segmentation
Yu Zhang, Jiang Liu, Qinghua Hu, and Manning Wang. Fcb- former: A fully convolutional bridge transformer with pyra- mid squeeze-excitation for colonoscopy segmentation. In Medical Image Computing and Computer Assisted Interven- tion (MICCAI), pages 352–363. Springer, 2023. 3
2023
-
[68]
Road extraction by deep residual u-net
Zhengxin Zhang, Qingjie Liu, and Yunhong Wang. Road extraction by deep residual u-net. IEEE Geoscience and Re- mote Sensing Letters, 15(5):749–753, 2018. 2, 6
2018
-
[69]
Road ex- traction by deep residual u-net
Zizhao Zhang, Qingjie Liu, and Yunhong Wang. Road ex- traction by deep residual u-net. IEEE Geoscience and Re- mote Sensing Letters, 15:749–753, 2018
2018
-
[70]
Unet++: A nested u-net architecture for medical image segmentation
Zongwei Zhou, Md Mahfuzur Rahman Siddiquee, Nima Tajbakhsh, and Jianming Liang. Unet++: A nested u-net architecture for medical image segmentation. arXiv preprint arXiv:1807.10165, 2018. 2 8
2018 arXiv
-
[2015]
https://arxiv.org/abs/1409.1556. 2 7
Reviewed August 5, 2026 · model on record in the stance chip above.
Discussion (0). Sign in to comment.