Pith. sign in

REVIEW 1 cited by

Cryogenic light detectors with enhanced performance for rare events physics

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1901.11009 v2 pith:5HDU3G5K submitted 2019-01-29 physics.ins-det nucl-ex

classification physics.ins-detnucl-ex
keywords lightdetectorcollectiontestedthermalbolometercrystalcuore
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, and (3) it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath. We tested this new technique with a 16 cm$^2$ Ge light detector with thermistor readout sitting on the surface of a large TeO$_2$ bolometer. The light collection efficiency was increased by greater than 50\% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20~eV RMS that, together with increased light collection, enabled us to obtain the best $\alpha$ vs $\beta/\gamma$ discrimination ever obtained with massive TeO$_2$ crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. CUPID pre-CDR

    physics.ins-det 2019-07 unverdicted novelty 4.0 of 10

    CUPID proposes a large bolometric detector array with alpha/beta discrimination to achieve a background-free search for 0νββ decay in 100Mo and probe the inverted neutrino mass hierarchy.

Pith tools