Pith. sign in

REVIEW 1 cited by

Holographic reconstruction of magnetic field distribution in a Josephson junction from diffraction-like Ic(H) patterns

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2205.12837 v2 pith:65WIB74K submitted 2022-05-25 cond-mat.supr-con physics.ins-det

Holographic reconstruction of magnetic field distribution in a Josephson junction from diffraction-like Ic(H) patterns

classification cond-mat.supr-con physics.ins-det
keywords magneticfieldjunctionmethodjosephsonproblemreconstructionimaging
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

A general problem of magnetic sensors is a trade-off between spatial resolution and magnetic field sensitivity. With decreasing sensor size its resolution is improved but the sensitivity is deteriorated. Obviation of such the trade-off requires development of super-resolution imaging technique, not limited by the sensor size. Here we present a proof of concept for a super-resolution method of magnetic imaging by a Josephson junction. It is based on a solution of an inverse problem - reconstruction of a local magnetic field distribution within a junction from the dependence of the critical current on an external magnetic field, Ic(H). The method resembles the Fourier-transform holography, with the diffraction-like Ic(H) pattern serving as a hologram. A simple inverse problem solution, valid for an arbitrary symmetric case, is derived. We verify the method numerically and show that the accuracy of reconstruction does not depend on the junction size and is only limited by the field range of the Ic(H) pattern. Finally, the method is tested experimentally using planar Nb Josephson junctions. Super-resolution reconstruction of stray magnetic fields from an Abrikosov vortex, trapped in the junction electrodes, is demonstrated. Thus, our method facilitate both the high field sensitivity and high spatial resolution, obviating the trade-off problem of magnetic sensors. We conclude that the holographic magnetic imaging by a planar Josephson junction can be used in scanning probe microscopy.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Building an AdS/BCFT Josephson junction within Horndeski gravity

    hep-th 2025-10 reject novelty 4.0

    AdS/BCFT with Horndeski gravity is claimed to yield Josephson junctions whose phase and current depend on the Horndeski couplings, but the condensate and critical temperature are put in by hand.