TeO₂ bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
read the original abstract
CUORE, an array of 988 TeO$_2$ bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from $\alpha$ radioactivity. A few years ago it has been pointed out that the signal from $\beta$s can be tagged by detecting the emitted Cherenkov light, which is not produced by $\alpha$s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the $Q$-value of the decay. To completely reject the $\alpha$ background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3-4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO$_2$ bolometric experiments able to probe the inverted hierarchy of neutrino masses.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
CUPID pre-CDR
CUPID proposes a large bolometric detector array with alpha/beta discrimination to achieve a background-free search for 0νββ decay in 100Mo and probe the inverted neutrino mass hierarchy.