Pith. sign in

REVIEW

A Reactive Molecular Dynamics Study on the Mechanical Properties of a Recently Synthesized Amorphous Carbon Monolayer Converted into a Nanotube/Nanoscroll

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2012.08059 v1 pith:DB4I4QUE submitted 2020-12-15 cond-mat.mtrl-sci cond-mat.mes-hall

classification cond-mat.mtrl-scicond-mat.mes-hall
keywords a-cnsa-cntamorphouspristinecarbonpropertiesrecentlycases
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Recently, laser-assisted chemical vapor deposition was used to synthesize a free-standing, continuous, and stable monolayer amorphous carbon (MAC). MAC is a pure carbon structure composed of randomly distributed five, six, seven, and eight atom rings, which differs from disordered graphene. More recently, amorphous MAC-based nanotubes (a-CNT) and nanoscrolls (A-CNS) were proposed. In this work, we have investigated (through fully atomistic reactive molecular dynamics simulations) the mechanical properties and melting points of pristine and a-CNT and a-CNS. Results showed that a-CNT and a-CNS have distinct elastic properties and fracture patterns concerning their pristine analogs. Both a-CNT and a-CNS presented a non-elastic regime before their total rupture, whereas the CNT and CNS undergo a direct conversion to fractured forms after a critical strain threshold. The critical strain for the fracture of the a-CNT and a-CNS are about 30% and 25%, respectively, and they are lower than the corresponding CNT and CNS cases. Although less resilient to tension, the amorphous tubular structures have similar thermal stability in relation to the pristine cases with melting points of 5500K, 6300K, 5100K, and 5900K for a-CNT, CNT, a-CNS, and CNS, respectively. An interesting result is whereas the behavior of the pristine systems is substantially different depending on the system being a nanotube or a nanoscroll, thus indicating that the topology plays an important role, the same is not true for the amorphous version of the nanostructures, thus indicating that the structural disorder overcomes the topological features.

Discussion (0). Continue with ORCID to comment.

Pith tools