REVIEW 2 major objections 1 minor 34 references
Uniaxial poroelastic tendon model with crimped fibre recruitment
T0 review · 2 major / 1 minor · reviewed 2026-06-25 · grok-4.3
Pith's one-line read Crimped fibrils in a poroelastic tendon model allow greater stretch without high strain on fibrils or matrix, creating a protection mechanism during loading and unloading.
desk verdict The paper adds crimped-fibre recruitment to a 1D poroelastic tendon model and shows resulting load-unload asymmetry, but the central claims rest on an unvalidated bespoke stress law with no data overlay or sensitivity checks. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The FIB model: a poroelastic solid whose neo-Hookean matrix is augmented by crimped fibrils that recruit upon straightening, governed by a diffusion equation whose coefficient depends on instantaneous stiffness.
What would settle it
Direct measurement of the time required for a real tendon specimen to reach steady-state extension under a constant uniaxial load, compared against the time required for the same specimen to return to its unloaded length after load release; absence of measurable asymmetry or of load-dependent hysteresis would falsify the central claim.
Extended reading notes
Core claim
In the FIB model the solid skeleton is a soft neo-Hookean matrix reinforced by crimped fibrils that bear no load until straightened. Under constant applied tension the tissue therefore stretches farther before the fibrils or non-collagenous matrix reach high strains, furnishing a natural protection mechanism. The stiffness-dependent diffusion coefficient makes the FIB model approach steady state more slowly than the pure neo-Hookean case during loading and far more slowly during unloading, when re-crimping softens the tissue; the resulting asymmetry appears as a hysteresis loop in the stress-strain curve whose size decreases with larger applied loads.
Load-bearing premise
The bespoke stress law that accounts for crimp and fibril recruitment, together with the assumption that the diffusion coefficient depends on stiffness, correctly captures the mechanical response of the FIB model within typical tendon parameter ranges.
Editorial extensions
If this is right
- The FIB model reaches steady state more slowly than the neo-Hookean model during loading because the recruited fibrils keep the composite softer.
- On unloading the FIB model relaxes much more slowly than the neo-Hookean model because fibril re-crimping further reduces stiffness.
- The loading-unloading asymmetry produces a hysteresis loop in the averaged stress-strain curve whose area shrinks as applied load increases.
- The explicit inclusion of crimped fibrils permits clearer biological interpretation and direct comparison with experimental recruitment data.
- Other fibril constitutive laws can be substituted into the same poroelastic framework without altering the overall structure.
Reading between the lines
- The same recruitment mechanism may underlie the low-strain toe region observed in cyclic tendon tests in vivo.
- Extending the model to spatially varying crimp angles could predict how regional differences in fibril waviness affect overall tendon compliance.
- The stiffness-dependent diffusion coefficient suggests that damage-induced softening would further slow fluid flow and recovery after injury.
- The framework could be used to explore how changes in fibril crimp statistics during aging or disease alter the hysteresis and protective capacity.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript presents a one-dimensional poroelastic model for tendons in which the solid skeleton combines a soft neo-Hookean matrix with crimped fibrils that do not bear load until straightened (FIB model). Under uniaxial constant load and subsequent unloading, the FIB model is reported to be softer than a pure neo-Hookean (NH) skeleton within tendon parameter ranges, to equilibrate more slowly, to permit greater overall stretch without excessive local strain on fibrils or matrix (a claimed protection mechanism), and to exhibit loading-unloading asymmetry that produces hysteresis in the averaged stress-strain response; the diffusion coefficient in the governing equation is stated to depend on instantaneous stiffness.
Significance. If the central claims hold after validation, the framework would supply a biologically interpretable poroelastic description of tendon recruitment that could account for observed hysteresis and strain partitioning, with the modular stress law allowing substitution of other fibril constitutive relations.
major comments (2)
- [Abstract] Abstract: the assertion that the FIB model is softer than NH and supplies a protection mechanism 'in agreement with experiments' is load-bearing for the central claim, yet the abstract supplies neither the explicit functional form of the bespoke stress law for crimp and recruitment, its derivation, nor any quantitative comparison to measured tendon curves or parameter-fitting procedure.
- [Abstract] Abstract: the diffusion equation is stated to have a stiffness-dependent coefficient, but no equation is written, no numerical implementation details are given, and the dependence creates a closed loop (stiffness is set by the same recruitment parameters that determine the diffusion coefficient); no sensitivity check is described to confirm that this produces the reported slower equilibration and hysteresis.
minor comments (1)
- [Abstract] The abstract states that other fibril constitutive laws 'can readily be considered,' but does not indicate how changes in the recruitment threshold or stiffness jump would affect the softness ordering or the protection effect.
Simulated Author's Rebuttal
We thank the referee for their constructive comments. We address each major comment below and indicate planned revisions.
read point-by-point responses
-
Referee: [Abstract] Abstract: the assertion that the FIB model is softer than NH and supplies a protection mechanism 'in agreement with experiments' is load-bearing for the central claim, yet the abstract supplies neither the explicit functional form of the bespoke stress law for crimp and recruitment, its derivation, nor any quantitative comparison to measured tendon curves or parameter-fitting procedure.
Authors: The abstract is a concise summary; the explicit piecewise stress law (zero load until crimp straightens, then neo-Hookean fibril extension) and its derivation from recruitment kinematics appear in the Methods. Agreement with experiments refers to qualitative features (greater extensibility before high local strains, load-dependent hysteresis) reported in the tendon literature, not a fitted dataset. We will revise the abstract to briefly note the stress-law form and clarify the qualitative nature of the comparison. A full quantitative fitting procedure lies outside the present scope. revision: partial
-
Referee: [Abstract] Abstract: the diffusion equation is stated to have a stiffness-dependent coefficient, but no equation is written, no numerical implementation details are given, and the dependence creates a closed loop (stiffness is set by the same recruitment parameters that determine the diffusion coefficient); no sensitivity check is described to confirm that this produces the reported slower equilibration and hysteresis.
Authors: The diffusion equation with instantaneous-stiffness-dependent diffusivity is written and derived in the Methods; the numerical scheme (implicit finite-difference time stepping with updated modulus at each step) is also detailed there. The coupling is not a closed loop: the effective modulus is evaluated from the current local strain and recruitment state during integration, which is standard for nonlinear poroelasticity. We agree a sensitivity study would strengthen the claims and will add one in revision to confirm the slower equilibration and hysteresis persist across the tendon parameter range. revision: partial
Circularity Check
No significant circularity; model results follow from constitutive assumptions and equation solving
full rationale
The paper defines a one-dimensional poroelastic model with a neo-Hookean background plus a bespoke stress law for crimped fibrils that contribute to load-bearing only after straightening, together with a diffusion coefficient that depends on the instantaneous stiffness arising from that law. All reported behaviors (FIB model softer than NH within parameter ranges, slower equilibration on loading, faster relaxation on unloading, hysteresis, and protection via extra stretch without excess fibril/NCM strain) are obtained by solving the resulting diffusion equation under these definitions and comparing the two skeletons. No step equates a claimed prediction to a fitted input by construction, invokes a self-citation as the sole justification for a uniqueness or ansatz choice, or renames an empirical pattern as a derived result. The bespoke character of the stress law is explicitly acknowledged and presented as an assumption that can be swapped, confirming the derivation chain remains self-contained rather than circular.
Assumptions & free parameters
free parameters (2)
- neo-Hookean matrix stiffness
- fibril stiffness and crimp parameters
assumptions (2)
- domain assumption Tissue behaves as a one-dimensional poroelastic continuum whose fluid flow is governed by a diffusion equation whose coefficient depends on instantaneous stiffness
- domain assumption Crimped fibrils carry zero load until straightened and then add to the solid stress
invented entities (1)
-
Bespoke stress law for crimped fibril recruitment
Cite this review
Pith. "Pith review of Uniaxial poroelastic tendon model with crimped fibre recruitment." pith.science (2026). https://pith.science/paper/HIHOBYRO
@misc{pith2026260624393,
author = {Pith},
title = {Pith review of: Uniaxial poroelastic tendon model with crimped fibre recruitment},
year = {2026},
howpublished = {\url{https://pith.science/paper/HIHOBYRO}},
note = {Machine review of arXiv:2606.24393}
}
read the original abstract
Fibre recruitment plays an important role in tendon and other biological soft tissue mechanics. Due to their large water content, a popular modelling approach for tendons is poroelasticity. Within this framework some tendon studies have included fibres, though none have included crimped fibre recruitment. We present a one dimensional poroelastic model in which the solid skeleton is composed of a soft neo-Hookean background matrix and crimped fibrils which do not bear load (FIB model). As the tissue is stretched, fibrils are straightened and contribute to load bearing. The fibre-reinforced tissue is compared to a tissue with a purely neo-Hookean (NH) skeleton in response to a uniaxial constant applied load (loading) and release of the load (unloading). The system dynamics are governed by a diffusion equation where the diffusion coefficient depends on stiffness. Within tendon parameter ranges, the FIB model is softer than the NH model, and so approaches steady state more slowly during loading. The presence of crimped fibrils allows the tendon to stretch further without excessively straining the fibrils or the NCM, providing a natural protection mechanism for the tendon's structural components to load, in agreement with experiments. During unloading, the FIB model is much slower to relax as the tissue softens due to fibril re-crimping. This asymmetry in loading and unloading manifests as a hysteresis loop in the stress-strain curve averaged over the tendon. The hysteresis is reduced with increasing applied load. The inclusion of fibrils allows for clearer biological interpretation and potential comparison to data. While the stress law employed in this study is bespoke for the application at hand by accounting for crimp and fibril recruitment, other fibril constitutive laws can readily be considered and incorporated into this framework.
Figures
Figures from the paper (4 more)
Reference graph
Works this paper leans on
-
[1]
Ahmadzadeh, B
H. Ahmadzadeh, B. R. Freedman, B. K. Connizzo, L. J. Soslowsky, and V. B. Shenoy. Microme- chanical poroelastic finite element and shear-lag models of tendon predict large strain dependent poisson’s ratios and fluid expulsion under tensile loading.Acta Biomaterialia, 22:83–91, 2015
2015
-
[2]
Atkinson, R
T. Atkinson, R. Haut, and N. Altiero. A poroelastic model that predicts some phenomenological responses of ligaments and tendons.Journal of biomechanical engineering, 1997
1997
-
[3]
Bojsen-Møller, K
J. Bojsen-Møller, K. Brogaard, M. Have, H. Stryger, M. Kjaer, P. Aagaard, and S. Magnusson. Passive knee joint range of motion is unrelated to the mechanical properties of the patellar tendon.Scandinavian Journal of Medicine & Science in Sports, 17(4):415–421, 2007
2007
-
[4]
Butler, S
S. Butler, S. Kohles, R. Thielke, C. Chen, and R. Vanderby Jr. Interstitial fluid flow in tendons or ligaments: a porous medium finite element simulation.Medical and Biological Engineering and Computing, 35(6):742–746, 1997
1997
-
[5]
C.-T. Chen, D. S. Malkus, and R. Vanderby Jr. A fiber matrix model for interstitial fluid flow and permeability in ligaments and tendons.Biorheology, 35(2):103–118, 1998
1998
-
[6]
A. H.-D. Cheng.Poroelasticity, volume 27. Springer, 2016
2016
-
[7]
Ciarletta, P
P. Ciarletta, P. Dario, and S. Micera. Pseudo-hyperelastic model of tendon hysteresis from adaptive recruitment of collagen type i fibrils.Biomaterials, 29(6):764–770, 2008
2008
-
[8]
Couppe, P
C. Couppe, P. Hansen, M. Kongsgaard, V. Kovanen, C. Suetta, P. Aagaard, M. Kjaer, and S. P. Magnusson. Mechanical properties and collagen cross-linking of the patellar tendon in old and young men.Journal of applied physiology, 2009. 22
2009
Show all 34 references
-
[9]
Diamant, A
J. Diamant, A. Keller, E. Baer, M. Litt, and R. Arridge. Collagen; ultrastructure and its relation to mechanical properties as a function of ageing.Proceedings of the Royal Society of London. Series B. Biological Sciences, 180(1060):293–315, 1972
1972
-
[10]
Fiori, S
M. Fiori, S. Pramanik, and C. W. MacMinn. Flow and deformation due to periodic loading in a soft porous material.Journal of Fluid Mechanics, 974:A2, 2023
2023
-
[11]
R. Gatt, M. V. Wood, A. Gatt, F. Zarb, C. Formosa, K. M. Azzopardi, A. Casha, T. P. Agius, P. Schembri-Wismayer, L. Attard, et al. Negative poisson’s ratios in tendons: An unexpected mechanical response.Acta biomaterialia, 24:201–208, 2015
2015
-
[12]
Z. C. Godard, D. E. Moulton, and S. L. Waters. Cyclic loading of a heterogeneous non-linear poroelastic material.Soft Matter, 2025
2025
-
[13]
K. Goh, D. Holmes, H.-Y. Lu, S. Richardson, K. Kadler, P. Purslow, and T. J. Wess. Ageing changes in the tensile properties of tendons: influence of collagen fibril volume fraction.Journal of biomechanical engineering, 2008
2008
-
[14]
Helland, J
C. Helland, J. Bojsen-Møller, T. Raastad, O. R. Seynnes, M. M. Moltubakk, V. Jakobsen, H. Visnes, and R. Bahr. Mechanical properties of the patellar tendon in elite volleyball players with and without patellar tendinopathy.British journal of sports medicine, 47(13):862–868, 2013
2013
-
[15]
M. G. Hennessy, T. Shearer, and A. C. Moore. A microstructure-informed continuum model of transversely isotropic, fibre-reinforced hydrogels.Journal of the Mechanics and Physics of Solids, page 106350, 2025
2025
-
[16]
T. A. J¨ arvinen, T. L. J¨ arvinen, P. Kannus, L. J´ ozsa, and M. J¨ arvinen. Collagen fibres of the spontaneously ruptured human tendons display decreased thickness and crimp angle.Journal of orthopaedic research, 22(6):1303–1309, 2004
2004
-
[17]
Kastelic, A
J. Kastelic, A. Galeski, and E. Baer. The multicomposite structure of tendon.Connective Tissue Research, 6(1):11–23, Jan. 1978. ISSN 1607-8438. doi: 10.3109/03008207809152283. URLhttp://dx.doi.org/10.3109/03008207809152283
1978 doi
-
[18]
Kastelic, I
J. Kastelic, I. Palley, and E. Baer. A structural mechanical model for tendon crimping.Journal of biomechanics, 13(10):887–893, 1980
1980
-
[19]
Khayyeri, A
H. Khayyeri, A. Gustafsson, A. Heuijerjans, M. K. Matikainen, P. Julkunen, P. Eliasson, P. As- penberg, and H. Isaksson. A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat achilles tendon.PloS one, 10(6):e0126869, 2015
2015
-
[20]
Kongsgaard, K
M. Kongsgaard, K. Qvortrup, J. Larsen, P. Aagaard, S. Doessing, P. Hansen, M. Kjaer, and S. P. Magnusson. Fibril morphology and tendon mechanical properties in patellar tendinopathy: effects of heavy slow resistance training.The American journal of sports medicine, 38(4):749– ...
2010
-
[21]
Lavagnino, S
M. Lavagnino, S. P. Arnoczky, E. Kepich, O. Caballero, and R. C. Haut. A finite element model predicts the mechanotransduction response of tendon cells to cyclic tensile loading. Biomechanics and Modeling in Mechanobiology, 7(5):405–416, October 2008. ISSN 1617-7940. doi: 10.1...
2008 doi
-
[22]
C. W. MacMinn. Large deformations of a soft porous material.Physical Review Ap- plied, 5(4), 2016. doi: 10.1103/PhysRevApplied.5.044020. URLhttps://doi.org/10.1103/ PhysRevApplied.5.044020
2016 doi
-
[23]
C. N. Maganaris and J. P. Paul. Hysteresis measurements in intact human tendon.Journal of biomechanics, 33(12):1723–1727, 2000
2000
-
[24]
G. N. Onamb´ el´ e, K. Burgess, and S. J. Pearson. Gender-specific in vivo measurement of the structural and mechanical properties of the human patellar tendon.Journal of orthopaedic research, 25(12):1635–1642, 2007
2007
-
[25]
S. G. Rees, J. R. Davies, D. Tudor, C. R. Flannery, C. E. Hughes, C. M. Dent, and B. Caterson. Immunolocalisation and expression of proteoglycan 4 (cartilage superficial zone proteoglycan) in tendon.Matrix Biology, 21(7):593–602, 2002
2002
-
[26]
B. N. Safa, E. T. Bloom, A. H. Lee, M. H. Santare, and D. M. Elliott. Evaluation of trans- verse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling.Journal of biomechanics, 109:109892, 2020
2020
-
[27]
Screen, D
H. Screen, D. Bader, D. Lee, and J. Shelton. Local strain measurement within tendon.Strain, 40(4):157–163, 2004
2004
-
[28]
Screen, D
H. Screen, D. Lee, D. Bader, and J. Shelton. An investigation into the effects of the hierarchical structure of tendon fascicles on micromechanical properties.Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 218(2):109–119, 2004
2004
-
[29]
T. Shearer. A new strain energy function for the hyperelastic modelling of ligaments and tendons based on fascicle microstructure.Journal of Biomechanics, 48(2):290–297, 2015. ISSN 0021-9290. doi: https://doi.org/10.1016/j.jbiomech.2014.11.031. URLhttps://www.sciencedirect.com...
2015 doi
-
[30]
Svensson, A
L. Svensson, A. Asz´ odi, F. P. Reinholt, R. F¨ assler, D. Heineg˚ ard, and˚A. Oldberg. Fibromodulin- null mice have abnormal collagen fibrils, tissue organization, and altered lumican deposition in tendon.Journal of Biological Chemistry, 274(14):9636–9647, 1999
1999
-
[31]
C. T. Thorpe, G. P. Riley, H. L. Birch, P. D. Clegg, and H. R. Screen. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons.Acta biomaterialia, 10(7):3217–3224, 2014. 24
2014
-
[32]
C. T. Thorpe, H. L. Birch, P. D. Clegg, and H. R. Screen. Tendon physiology and mechanical behavior: structure–function relationships. InTendon regeneration, pages 3–39. Elsevier, 2015
2015
-
[33]
Vergari, P
C. Vergari, P. Pourcelot, L. Holden, B. Ravary-Plumio¨ en, G. Gerard, P. Laugier, D. Mitton, and N. Crevier-Denoix. True stress and poisson’s ratio of tendons during loading.Journal of biomechanics, 44(4):719–724, 2011
2011
-
[34]
T. A. Wren, G. S. Beaupre, and D. R. Carter. Mechanobiology of tendon adaptation to com- pressive loading through fibrocartilaginous metaplasia.Journal of rehabilitation research and development, 37(2):135–144, 2000. 25
2000
Reviewed June 25, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.