REVIEW 3 cited by
WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image Synthesis
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image Synthesis
read the original abstract
Due to the three-dimensional nature of CT- or MR-scans, generative modeling of medical images is a particularly challenging task. Existing approaches mostly apply patch-wise, slice-wise, or cascaded generation techniques to fit the high-dimensional data into the limited GPU memory. However, these approaches may introduce artifacts and potentially restrict the model's applicability for certain downstream tasks. This work presents WDM, a wavelet-based medical image synthesis framework that applies a diffusion model on wavelet decomposed images. The presented approach is a simple yet effective way of scaling 3D diffusion models to high resolutions and can be trained on a single \SI{40}{\giga\byte} GPU. Experimental results on BraTS and LIDC-IDRI unconditional image generation at a resolution of $128 \times 128 \times 128$ demonstrate state-of-the-art image fidelity (FID) and sample diversity (MS-SSIM) scores compared to recent GANs, Diffusion Models, and Latent Diffusion Models. Our proposed method is the only one capable of generating high-quality images at a resolution of $256 \times 256 \times 256$, outperforming all comparing methods.
Forward citations
Cited by 3 Pith papers
-
Agentic Autoresearch for CT Reconstruction
An LLM agent autonomously benchmarked 26 CT reconstruction methods and showed that adding mild noise nearly inverts the clean-data ranking, with retraining partially restoring it.
-
PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping
A self-supervised, physics-regularized neural reconstruction produces high-resolution fetal brain T2 maps at 0.55 T and 1.5 T from multi-echo MRI, with reduced acquisition time.
-
TCAM-Diff: Triplane-Aware Cross-Attention Medical Diffusion Model
TCAM-Diff fits 3D medical volumes into triplane features via a decoder-only autoencoder and generates new volumes with a cross-attention diffusion model, reporting better reconstruction and generation scores than VAE/...
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.