Pith. sign in

REVIEW 1 cited by

Learning to Enhance Aperture Phasor Field for Non-Line-of-Sight Imaging

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.18574 v2 pith:Q5GTZQLA submitted 2024-07-26 cs.CV

classification cs.CV
keywords networkfrequencymeasurementssignalstimesaperturedenoisingenhancement
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

This paper aims to facilitate more practical NLOS imaging by reducing the number of samplings and scan areas. To this end, we introduce a phasor-based enhancement network that is capable of predicting clean and full measurements from noisy partial observations. We leverage a denoising autoencoder scheme to acquire rich and noise-robust representations in the measurement space. Through this pipeline, our enhancement network is trained to accurately reconstruct complete measurements from their corrupted and partial counterparts. However, we observe that the \naive application of denoising often yields degraded and over-smoothed results, caused by unnecessary and spurious frequency signals present in measurements. To address this issue, we introduce a phasor-based pipeline designed to limit the spectrum of our network to the frequency range of interests, where the majority of informative signals are detected. The phasor wavefronts at the aperture, which are band-limited signals, are employed as inputs and outputs of the network, guiding our network to learn from the frequency range of interests and discard unnecessary information. The experimental results in more practical acquisition scenarios demonstrate that we can look around the corners with $16\times$ or $64\times$ fewer samplings and $4\times$ smaller apertures. Our code is available at https://github.com/join16/LEAP.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Optimized Sampling for Non-Line-of-Sight Imaging Using Modified Fast Fourier Transforms

    eess.IV 2025-01 conditional novelty 6.0 of 10

    Scaled and non-uniform FFT variants of the Rayleigh-Sommerfeld diffraction algorithm reconstruct NLOS scenes with flexible sampling grids and depth-dependent voxel sizes at FFT-level complexity.

Pith tools