Pith. sign in

REVIEW

Planck Early Results. V. The Low Frequency Instrument data processing

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1101.2040 v4 pith:Q5IALK2C submitted 2011-01-11 astro-ph.IM astro-ph.CO

Planck Early Results. V. The Low Frequency Instrument data processing

A. Zacchei , D. Maino , C. Baccigalupi , M. Bersanelli , A. Bonaldi , L. Bonavera , C. Burigana , R. C. Butler
show 141 more authors
F. Cuttaia G. de Zotti J. Dick M. Frailis S. Galeotta J. Gonz\'alez-Nuevo K. M. G\'orski A. Gregorio E. Keih\"anen R. Keskitalo J. Knoche H. Kurki-Suonio C. R. Lawrence S. Leach J. P. Leahy M. L\'opez-Caniego N. Mandolesi M. Maris F. Matthai P. R. Meinhold A. Mennella G. Morgante N. Morisset P. Natoli F. Pasian F. Perrotta G. Polenta T. Poutanen M. Reinecke S. Ricciardi R. Rohlfs M. Sandri A.-S. Suur-Uski J. A. Tauber D. Tavagnacco L. Terenzi M. Tomasi J. Valiviita F. Villa A. Zonca A. J. Banday R. B. Barreiro J. G. Bartlett N. Bartolo L. Bedini K. Bennett P. Binko J. Borrill F. R. Bouchet M. Bremer P. Cabella B. Cappellini X. Chen L. Colombo M. Cruz A. Curto L. Danese R. D. Davies R. J. Davis G. de Gasperis A. de Rosa G. de Troia C. Dickinson J. M. Diego S. Donzelli U. D\"orl G. Efstathiou T. A. En{\ss}lin H. K. Eriksen M. C. Falvella F. Finelli E. Franceschi T. C. Gaier F. Gasparo R. T. G\'enova-Santos G. Giardino F. G\'omez A. Gruppuso F. K. Hansen R. Hell D. Herranz W. Hovest M. Huynh J. Jewell M. Juvela T. S. Kisner L. Knox A. L\"ahteenm\"aki J.-M. Lamarre R. Leonardi J. Le\'on-Tavares P. B. Lilje P. M. Lubin G. Maggio D. Marinucci E. Mart\'inez-Gonz\'alez M. Massardi S. Matarrese M. T. Meharga A. Melchiorri M. Migliaccio S. Mitra A. Moss H. U. N{\o}rgaard-Nielsen L. Pagano R. Paladini D. Paoletti B. Partridge D. Pearson V. Pettorino D. Pietrobon G. Pr\'ezeau P. Procopio J.-L. Puget C. Quercellini J. P. Rachen R. Rebolo G. Robbers G. Rocha J. A. Rubi\~no-Mart\'in E. Salerno M. Savelainen D. Scott M. D. Seiffert J. I. Silk G. F. Smoot J. Sternberg F. Stivoli R. Stompor G. Tofani L. Toffolatti J. Tuovinen M. T\"urler G. Umana P. Vielva N. Vittorio C. Vuerli L. A. Wade R. Watson S. D. M. White A. Wilkinson
This is my paper
classification astro-ph.IM astro-ph.CO
keywords datanoisefrequencyplanckcalibratedearlyestimatedinstrument
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry packets to cleaned, calibrated, time-ordered data (TOD) and frequency maps. Data are continuously calibrated using the modulation of the temperature of the cosmic microwave background radiation induced by the motion of the spacecraft. Noise properties are estimated from TOD from which the sky signal has been removed using a generalized least square map-making algorithm. Measured 1/f noise knee-frequencies range from 100mHz at 30GHz to a few tens of mHz at 70GHz. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices required to compute statistical uncertainties on LFI and Planck products are also produced. Main beams are estimated down to the approx -10dB level using Jupiter transits, which are also used for geometrical calibration of the focal plane.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.