Pith. sign in

REVIEW 1 cited by

Polarization-artifact reduction and accuracy improvement of Jones-matrix polarization-sensitive optical coherence tomography by multi-focus averaging

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2310.12761 v2 pith:UDQFID3L submitted 2023-10-19 physics.optics physics.bio-phphysics.ins-detphysics.med-ph

Polarization-artifact reduction and accuracy improvement of Jones-matrix polarization-sensitive optical coherence tomography by multi-focus averaging

classification physics.optics physics.bio-phphysics.ins-detphysics.med-ph
keywords signalsaccuracymethodaveragingmeasurementps-octvolumesartifacts
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

Polarization-sensitive optical coherence tomography (PS-OCT) is a promising biomedical imaging tool for differentiation of various tissue properties. However, the presence of multiple-scattering (MS) signals can degrade the quantitative polarization measurement accuracy. We demonstrate a method to reduce MS signals and increase the measurement accuracy of Jones matrix PS-OCT. This method suppresses MS signals by averaging of multiple Jones matrix volumes measured using different focal positions. The MS signals are decorrelated among the volumes by focus position modulation and are thus reduced by averaging. However, the single scattering signals are kept consistent among the focus-modulated volumes by computational refocusing. We validated the proposed method using a scattering phantom and a postmortem medaka fish. The results showed reduced artifacts in birefringence and degree-of-polarization uniformity measurements, particularly in deeper regions in the samples. This method offers a practical solution to mitigate MS-induced artifacts in PS-OCT imaging and improves quantitative polarization measurement accuracy.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. CoT-X: An Adaptive Framework for Cross-Model Chain-of-Thought Transfer and Optimization

    cs.AI 2025-11 conditional novelty 5.0

    An adaptive summarization framework compresses chain-of-thought traces and transfers them across model families, claiming up to 40.5% accuracy gains over truncation on medical QA and 84% fewer configuration evaluation...