FHRFormer: A Self-Supervised Masked Transformer Framework for Fetal Heart Rate Time-Series Inpainting and Forecasting
Reviewed by Pith T0 review T1 audit T2 compute T3 formal T4 kernel 2026-06-29 07:02 UTCgrok-4.3pith:XYJJOR5Arecord.jsonopen to challenge →
The pith
A masked transformer autoencoder reconstructs missing fetal heart rate signals by capturing temporal and frequency components.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
The authors establish that a masked transformer-based autoencoder trained self-supervised on FHR data reconstructs missing signals by capturing both local temporal and frequency components, demonstrating robustness across different durations of missing data for inpainting and forecasting tasks.
What carries the argument
Masked transformer-based autoencoder that masks portions of the input time series and learns to reconstruct them while modeling temporal sequences and frequency content.
If this is right
- The approach can be applied retrospectively to research datasets to support development of AI-based algorithms for predicting risk of needing breathing assistance at birth.
- It addresses the failure of interpolation methods to preserve spectral characteristics of FHR signals.
- Future integration into wearable FHR monitors could enable earlier and more robust risk detection during labor.
- It permits continuous fetal monitoring without data loss from maternal movement or position changes.
Where Pith is reading between the lines
- The same reconstruction approach could apply to other intermittently dropout-prone biomedical signals such as ECG or blood pressure traces.
- Real-time device integration would require separate checks on computational latency and power use under live conditions.
- Combining inpainted signals directly with labeled outcome data might improve end-to-end models for obstetric intervention prediction.
Load-bearing premise
That a standard masked transformer autoencoder trained in a self-supervised manner on FHR data will successfully preserve clinically relevant spectral and temporal features without additional domain-specific constraints or labeled examples.
What would settle it
A test set experiment in which the power spectrum or variability metrics of the reconstructed signals differ significantly from those of complete original recordings across multiple gap lengths would falsify the robustness claim.
Figures
read the original abstract
Approximately 10% of newborns require assistance to initiate breathing at birth, and around 5% need ventilation support. Fetal heart rate (FHR) monitoring plays a crucial role in assessing fetal well-being during prenatal care, enabling the detection of abnormal patterns and supporting timely obstetric interventions to mitigate fetal risks during labor. Applying artificial intelligence (AI) methods to analyze large datasets of continuous FHR monitoring episodes with diverse outcomes may offer novel insights into predicting the risk of needing breathing assistance or interventions. Recent advances in wearable FHR monitors have enabled continuous fetal monitoring without compromising maternal mobility. However, sensor displacement during maternal movement, as well as changes in fetal or maternal position, often lead to signal dropout, resulting in gaps in recorded FHR data. Such missing data limits the extraction of meaningful insights and complicates automated (AI-based) analysis. Traditional approaches to handling missing data, such as simple interpolation techniques, often fail to preserve the spectral characteristics of the signals. In this paper, we propose a masked transformer-based autoencoder approach to reconstruct missing FHR signals by capturing both local temporal and frequency components of the data. The proposed method demonstrates robustness across varying durations of missing data and can be used for signal inpainting and forecasting. The proposed approach can be applied retrospectively to research datasets to support the development of AI-based risk algorithms. In the future, the proposed method could be integrated into wearable FHR monitoring devices to achieve earlier and more robust risk detection.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper proposes FHRFormer, a self-supervised masked transformer-based autoencoder for inpainting and forecasting fetal heart rate (FHR) time-series signals. It addresses gaps from sensor dropout in wearable monitors by capturing local temporal and frequency components, claiming robustness across varying missing-data durations for retrospective use in AI-based fetal risk algorithms and potential future device integration.
Significance. If the empirical claims hold, the work could meaningfully improve handling of incomplete FHR recordings compared with interpolation, supporting downstream AI models for neonatal intervention prediction. The self-supervised formulation is well-matched to the unlabeled nature of continuous monitoring data.
major comments (1)
- [Abstract] Abstract: the central claim that the method 'demonstrates robustness across varying durations of missing data' is unsupported by any quantitative results, baselines, error metrics, dataset descriptions, or experimental sections in the provided manuscript text, rendering the primary contribution unevaluable.
minor comments (1)
- [Abstract] Abstract: the phrase 'capturing both local temporal and frequency components' is stated without indicating the architectural mechanism (e.g., explicit spectral layers, Fourier features, or learned filters).
Simulated Author's Rebuttal
We thank the referee for their review and for highlighting this important issue with the abstract. We address the comment below.
read point-by-point responses
-
Referee: [Abstract] Abstract: the central claim that the method 'demonstrates robustness across varying durations of missing data' is unsupported by any quantitative results, baselines, error metrics, dataset descriptions, or experimental sections in the provided manuscript text, rendering the primary contribution unevaluable.
Authors: We agree that the abstract claim is unsupported by any quantitative evidence, baselines, metrics, datasets, or experimental sections in the manuscript text. This renders the primary contribution unevaluable from the provided material. We will revise the manuscript by either removing or qualifying the unsupported claim in the abstract, or by adding the required experimental results, baselines, error metrics, and dataset descriptions to substantiate it. The revised version will ensure the contribution is properly supported and evaluable. revision: yes
Circularity Check
No significant circularity detected
full rationale
The paper describes a standard self-supervised masked transformer autoencoder for FHR time-series inpainting and forecasting. No equations, parameter-fitting procedures, derivations, or self-citations appear in the abstract or method outline that reduce any claimed prediction or result to its own inputs by construction. The approach relies on established transformer masking techniques applied to the domain, without any load-bearing step that renames a fit as a prediction or imports uniqueness via prior author work. The derivation chain is therefore self-contained against external benchmarks and receives the default non-circularity finding.
Axiom & Free-Parameter Ledger
Reference graph
Works this paper leans on
-
[1]
, " * write output.state after.block = add.period write newline
ENTRY address annote author booktitle chapter doi edition editor eid howpublished institution journal key language month note number organization pages publisher school series title type volume year label extra.label sort.label short.list INTEGERS output.state before.all mid.sentence after.sentence after.block FUNCTION init.state.consts #0 'before.all := ...
-
[2]
write newline
" write newline "" before.all 'output.state := FUNCTION n.dashify 't := "" t empty not t #1 #1 substring "-" = t #1 #2 substring "--" = not "--" * t #2 global.max substring 't := t #1 #1 substring "-" = "-" * t #2 global.max substring 't := while if t #1 #1 substring * t #2 global.max substring 't := if while FUNCTION word.in bbl.in capitalize " " * FUNCT...
-
[3]
, " * write output.state after.block = add.period write newline
ENTRY address author booktitle chapter doi edition editor eid howpublished institution journal key language month note number organization pages publisher school series title type volume year label extra.label sort.label short.list INTEGERS output.state before.all mid.sentence after.sentence after.block FUNCTION init.state.consts #0 'before.all := #1 'mid...
-
[4]
write newline
" write newline "" before.all 'output.state := FUNCTION n.dashify 't := "" t empty not t #1 #1 substring "-" = t #1 #2 substring "--" = not "--" * t #2 global.max substring 't := t #1 #1 substring "-" = "-" * t #2 global.max substring 't := while if t #1 #1 substring * t #2 global.max substring 't := if while FUNCTION word.in "" FUNCTION format.date year ...
-
[5]
Alfirevic, Z., Gyte, G. M. L., Cuthbert, A., and Devane, D. (2017). Continuous cardiotocography ( CTG ) as a form of electronic fetal monitoring ( EFM ) for fetal assessment during labour. Cochrane Database of Systematic Reviews 2, CD006066. doi:10.1002/14651858.CD006066.pub3 alfirevic2017
-
[6]
and Imtiaz, M
Alim, A. and Imtiaz, M. H. (2023). Wearable sensors for the monitoring of maternal health—a systematic review. Sensors 23, 2411 alim2023wearable
2023
-
[7]
Barzideh, F., Urdal, J., Hussein, K., Engan, K., Skretting, K., Mdoe, P., et al. (2018). Estimation of missing data in fetal heart rate signals using shift-invariant dictionary. In 2018 26th European Signal Processing Conference (EUSIPCO) (IEEE), 762--766 barzideh2018estimation
2018
-
[8]
Boudet, S., Houz \'e de l’Aulnoit, A., Peyrodie, L., Demailly, R., and Houz \'e de l’Aulnoit, D. (2022). Use of deep learning to detect the maternal heart rate and false signals on fetal heart rate recordings. Biosensors 12, 691 boudet2022use
2022
-
[9]
Campos, I., Gon c alves, H., Bernardes, J., and Castro, L. (2024). Fetal heart rate preprocessing techniques: A scoping review. Bioengineering 11, 368 campos2024fetal
2024
-
[10]
Cesarelli, M., Romano, M., Ruffo, M., Bifulco, P., Pasquariello, G., and Fratini, A. (2011). Psd modifications of fhrv due to interpolation and ctg storage rate. Biomedical Signal Processing and Control 6, 225--230 cesarelli2011psd
2011
-
[11]
Cockburn, N., Osborne, C., Withana, S., Elsmore, A., Nanjappa, R., South, M., et al. (2024). Clinical decision support systems for maternity care: a systematic review and meta-analysis. EClinicalMedicine 76 cockburn2024clinical
2024
-
[12]
Da Poian, G., Bernardini, R., and Rinaldo, R. (2015). Sparse representation for fetal qrs detection in abdominal ecg recordings. In 2015 E-Health and Bioengineering Conference (EHB) (IEEE), 1--4 da2015sparse
2015
-
[13]
G., and Djuri \'c , P
Dash, S., Quirk, J. G., and Djuri \'c , P. M. (2014). Fetal heart rate classification using generative models. IEEE Transactions on Biomedical Engineering 61, 2796--2805 dash2014fetal
2014
-
[14]
Dawes, A., Ameh, C., Moxon, S., Gannon, H., Jha, A., Basnet, O., et al. (2021). Neonatal resuscitation and immediate newborn assessment and stimulation for the prevention of neonatal deaths: A systematic review, meta-analysis and delphi estimation of mortality effect. BMC Public Health 21, 1--14. doi:10.1186/s12889-020-10033-8. Published online December 2...
-
[15]
Garza, A., Challu, C., and Mergenthaler-Canseco, M. (2023). Timegpt-1. arXiv preprint arXiv:2310.03589 garza2023timegpt
work page Pith review arXiv 2023
-
[16]
J., Moulden, M., and Redman, C
Georgieva, A., Payne, S. J., Moulden, M., and Redman, C. W. (2013). Artificial neural networks applied to fetal monitoring in labour. Neural Computing and Applications 22, 85--93 georgieva2013artificial
2013
-
[17]
K., Catelli, D
Ghosh, A. K., Catelli, D. S., Wilson, S., Nowlan, N. C., and Vaidyanathan, R. (2024). Multi-modal detection of fetal movements using a wearable monitor. Information Fusion 103, 102124 ghosh2024multi
2024
-
[18]
Jiang, L., Dai, B., Wu, W., and Loy, C. C. (2021). Focal frequency loss for image reconstruction and synthesis. In Proceedings of the IEEE/CVF international conference on computer vision. 13919--13929 jiang2021focal
2021
-
[19]
and Rizzo, G
Kanwal, N. and Rizzo, G. (2022). Attention-based clinical note summarization. In Proceedings of the 37th ACM/SIGAPP symposium on applied computing. 813--820 kanwal2022attention
2022
-
[20]
Katebijahromi, N. (2021). Detection of Adverse Events in Pregnancy Using a Low-Cost 1D Doppler Ultrasound Signal. Ph.D. thesis, Emory University katebijahromi2021detection
2021
-
[21]
Moyo fetal heart rate monitor
[Dataset] Laerdal-Global-Health (2025). Moyo fetal heart rate monitor. https://shop.laerdalglobalhealth.com/product/moyo/. Accessed 23 July 2025 laerdal_moyo
2025
-
[22]
Lin, Z., Liu, X., Wang, N., Li, R., Liu, Q., Ma, J., et al. (2024). Deep learning with information fusion and model interpretation for long-term prenatal fetal heart rate data. npj Women's Health 2, 31 lin2024deep
2024
-
[23]
A., Levine, L
McCoy, J. A., Levine, L. D., Wan, G., Chivers, C., Teel, J., and La Cava, W. G. (2025). Intrapartum electronic fetal heart rate monitoring to predict acidemia at birth with the use of deep learning. American Journal of Obstetrics and Gynecology 232, 116--e1 mccoy2025intrapartum
2025
-
[24]
L., Chen, S., Ogata, Y., Suzuki, M., Kobayashi, Y., Toda, M., et al
Mwakawanga, D. L., Chen, S., Ogata, Y., Suzuki, M., Kobayashi, Y., Toda, M., et al. (2024). Barriers and facilitators of fetal heart monitoring with a mobile cardiotocograph (ictg) device in underserved settings: An exploratory qualitative study from tanzania. PloS one 19, e0314812 mwakawanga2024barriers
2024
-
[25]
Nageotte, M. P. (2015). Fetal heart rate monitoring. In Seminars in fetal and neonatal medicine (Elsevier), vol. 20, 144--148 nageotte2015fetal
2015
-
[26]
P., Spilka, J., Stylios, C
Oikonomou, V. P., Spilka, J., Stylios, C. D., and Lhotsk \'a , L. (2013). An adaptive method for the recovery of missing samples from fhr time series. In CBMS. 337--342 oikonomou2013adaptive
2013
-
[27]
A., Redman, W
Petrozziello, A., Jordanov, I., Papageorghiou, T. A., Redman, W. C., and Georgieva, A. (2018). Deep learning for continuous electronic fetal monitoring in labor. In 2018 40th annual international conference of the IEEE engineering in medicine and biology society (EMBC) (IEEE), 5866--5869 petrozziello2018deep
2018
-
[28]
Rao, L., Lu, J., Wu, H.-R., Zhao, S., Lu, B.-C., and Li, H. (2024). Automatic classification of fetal heart rate based on a multi-scale lstm network. Frontiers in Physiology 15, 1398735 rao2024automatic
2024
-
[29]
Ribeiro, M., Monteiro-Santos, J., Castro, L., Antunes, L., Costa-Santos, C., Teixeira, A., et al. (2021). Non-linear methods predominant in fetal heart rate analysis: a systematic review. Frontiers in Medicine 8, 661226 ribeiro2021non
2021
-
[30]
Spilka, J., Chud \'a c ek, V., Kouck \`y , M., Lhotsk \'a , L., Huptych, M., Jank, P., et al. (2012). Using nonlinear features for fetal heart rate classification. Biomedical signal processing and control 7, 350--357 spilka2012using
2012
-
[31]
abnormal
Spilka, J., Georgoulas, G., Karvelis, P., Chud \'a c ek, V., Stylios, C. D., and Lhotsk \'a , L. (2014). Discriminating normal from “abnormal” pregnancy cases using an automated fhr evaluation method. In Artificial Intelligence: Methods and Applications: 8th Hellenic Conference on AI, SETN 2014, Ioannina, Greece, May 15-17, 2014. Proceedings 8 (Springer),...
2014
-
[32]
Spyridou, K. K. and Hadjileontiadis, L. J. (2007). Analysis of fetal heart rate in healthy and pathological pregnancies using wavelet-based features. In 2007 29th annual international conference of the ieee engineering in medicine and biology society (IEEE), 1908--1911 spyridou2007analysis
2007
-
[33]
Tahir Hussain Rizvi, S., Kanwal, N., Naeem, M., Cuzzocrea, A., and Coronato, A. (2025). Bridging simplicity and sophistication using glinear: A novel architecture for enhanced time series prediction. arXiv e-prints , arXiv--2501 tahir2025bridging
2025
-
[34]
B., Kidanto, H., and Ersdal, H
Urdal, J., Engan, K., Eftest l, T., Yarrot, L. B., Kidanto, H., and Ersdal, H. (2019). Noise and contraction detection using fetal heart rate and accelerometer signals during labour. In Proceedings of the 17th Scandinavian Conference on Health Informatics. vol. 12, 13 urdal2019noise
2019
-
[35]
N., et al
Vaswani, A., Shazeer, N., Parmar, N., Uszkoreit, J., Jones, L., Gomez, A. N., et al. (2017). Attention is all you need. Advances in neural information processing systems 30 vaswani2017attention
2017
-
[36]
N., Lee, A
Wall, S. N., Lee, A. C., Niermeyer, S., English, M., Keenan, W. J., Carlo, W., et al. (2009). Neonatal resuscitation in low-resource settings: what, who, and how to overcome challenges to scale up? International Journal of Gynecology & Obstetrics 107, S47--S64 wall2009neonatal
2009
-
[37]
Wang, J., Pei, S., Yang, Y., and Wang, H. (2024). Convolutional transformer-driven robust electrocardiogram signal denoising framework with adaptive parametric relu. Math Biosci Eng 21, 4286--4308 wang2024convolutional
2024
-
[38]
Xu, L., Wang, G., Cao, Z., Chen, Q., Liu, G., and Wei, H. (2023). Research on multimodal deep learning based on cnn and vit for intrapartum fetal monitoring. In 2023 IEEE International Conference on Bioinformatics and Biomedicine (BIBM) (IEEE), 4459--4464 xu2023research
2023
-
[39]
Zhang, H., Liu, W., Shi, J., Chang, S., Wang, H., He, J., et al. (2022). Maefe: Masked autoencoders family of electrocardiogram for self-supervised pretraining and transfer learning. IEEE Transactions on Instrumentation and Measurement 72, 1--15 zhang2022maefe
2022
-
[40]
Zhang, W., Yang, L., Geng, S., and Hong, S. (2023). Self-supervised time series representation learning via cross reconstruction transformer. IEEE Transactions on Neural Networks and Learning Systems zhang2023self
2023
-
[41]
Zhao, Z., Deng, Y., Zhang, Y., Zhang, Y., Zhang, X., and Shao, L. (2019). Deepfhr: intelligent prediction of fetal acidemia using fetal heart rate signals based on convolutional neural network. BMC medical informatics and decision making 19, 1--15 zhao2019deepfhr
2019
-
[42]
Zhao, Z., Zhang, Y., and Deng, Y. (2018). A comprehensive feature analysis of the fetal heart rate signal for the intelligent assessment of fetal state. Journal of Clinical Medicine 7. doi:10.3390/jcm7080223 jcm7080223
-
[43]
Zhong, M., Yi, H., Lai, F., Liu, M., Zeng, R., Kang, X., et al. (2022). Ctgnet: automatic analysis of fetal heart rate from cardiotocograph using artificial intelligence. Maternal-Fetal Medicine 4, 103--112 zhong2022ctgnet
2022
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.