REVIEW 3 major objections 7 minor 47 references
Practical Design and Benchmarking of Generative AI Applications for Surgical Billing and Coding
T0 review · 3 major / 7 minor · reviewed 2026-08-10 · deepseek-v4-flash
Pith's one-line read A locally fine-tuned small language model can generate surgical billing codes from operative reports as accurately as GPT-4o, while training on four consumer-grade 24GB GPUs.
desk verdict A useful, mostly sound empirical benchmark of fine-tuned Phi-3 models for surgical billing coding, but the undisclosed GPT-4o baseline makes the headline comparison unauditable. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing mechanism is QLoRA (quantized low-rank adaptation), a parameter-efficient fine-tuning method that trains small adapter matrices on a 4-bit quantized base model, applied to the Phi-3 family of small open-weight language models. The authors fine-tuned Phi-3 Mini and Phi-3 Medium on paired operative reports and billing claims, using the model's unused special tokens to segment the prompt into system, user, and assistant components so the model learns the claim format. At inference they used greedy decoding with a repetition penalty and a 512-token limit, and they merged the trained adapters back into the models. This mechanism carries the argument because it is what converts a general chat model into a structured billing-claim generator while keeping training feasible on four 24GB GPUs.
What would settle it
Re-run the same test set with GPT-4o using the exact structured prompt, special-token segmentation, greedy decoding, and output-format instruction used for the fine-tuned Phi-3 models, and compare exact-match recall and precision on ICD-10, CPT, and modifier codes. If GPT-4o then matches or exceeds the fine-tuned Phi-3 Medium, the paper's central comparison would not survive.
Extended reading notes
Core claim
The paper claims that a small open-weight language model, fine-tuned with parameter-efficient supervised learning on institution-specific operative reports and their associated billing claims, can generate ICD-10, CPT, and modifier codes from an operative report as accurately as or more accurately than GPT-4o. In the authors' benchmark, the fine-tuned Phi-3 Medium performed best, with ICD-10 recall and precision of 72% and 72%, CPT recall and precision of 77% and 79%, and modifier recall and precision of 63% and 64%; the fine-tuned Phi-3 Mini also performed better than or as well as GPT-4o. The Medium model fabricated only 1% of ICD-10 codes and 0.6% of CPT codes, which the authors contrast with roughly half of base-model ICD-10 codes being invalid. The authors' conclusion is that task-specific fine-tuning on local data, with simple open-source tooling and four 24GB GPUs, can close the gap with much larger general-purpose models on a real clinical documentation task.
Load-bearing premise
The load-bearing premise is that the GPT-4o baseline was given a fair and comparably optimized prompt and decoding setup; the paper reports the Phi-3 prompts in full but does not specify GPT-4o's prompt, model version, temperature, or generation settings.
Editorial extensions
If this is right
- A health system with four 24GB GPUs can build a private, on-site billing-code generator without sending protected health information to an external API.
- Fine-tuned small models reduce code fabrication to roughly 1%, which is what makes a coder-assist tool practical; the base and RAG configurations fabricated codes far more often.
- Fine-tuning on institutional data outperforms retrieval-augmented prompting for exact code-set generation, suggesting that for highly structured outputs in-domain weights matter more than in-context examples.
- The paper's own conclusion bounds the claim: these models are not coder replacements and did not show reduced staffing or faster claim submission, but they could serve as a lower-cost alternative to commercial computer-assisted coding software.
- Because both fine-tuned models matched or exceeded GPT-4o, model scale is not the decisive factor for this structured coding task; task-specific adaptation is.
Reading between the lines
- If the result generalizes, the same local fine-tuning recipe could be applied to other structured clinical-extraction tasks, such as pulling diagnoses from pathology or radiology reports, where privacy and exact vocabulary matter.
- The reported comparison would be strengthened by a head-to-head rerun in which GPT-4o receives the exact same structured prompt and decoding settings as the Phi-3 models; the paper does not disclose GPT-4o's prompt, so part of the measured gap could be prompt-format rather than model capability.
- Adding the History and Physical text, which the paper identifies as the source coders use for diagnosis codes, would likely improve ICD-10 recall and precision beyond the reported levels.
- Because the evaluation counts only exact code-set matches as correct, the reported recall and precision may understate the clinical usefulness of outputs that are semantically appropriate but differ from the submitted bill; a family-level or coder-reviewed metric would test that.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper evaluates four locally deployed Phi-3-based configurations (base Mini, Mini with RAG, fine-tuned Mini, fine-tuned Medium) against GPT-4o on the task of generating ICD-10-CM, CPT, and modifier codes from operative reports. The authors fine-tune Phi-3 Mini and Phi-3 Medium with QLoRA on institutional surgical billing data, run inference with greedy decoding and repetition penalty, and measure exact-code recall/precision, fabrication rates, and output-format fidelity. The headline claim is that the fine-tuned models perform as well as or better than GPT-4o while requiring only four 24GB consumer GPUs for training. The study uses a large real-world dataset (192,585 encounters), a held-out split in principle, bootstrap confidence intervals, and validity checks against reference code lists. The abstract reports that the fine-tuned Phi-3 Medium achieves ICD-10 recall/precision of 72%/72%, CPT recall/precision of 77%/79%, and modifier recall/precision of 63%/64%.
Significance. If the comparative results are sound, this is a practically valuable demonstration: small open models fine-tuned on institution-specific data can approach or match a much larger commercial model on a real clinical documentation task while keeping data on-premises and using modest hardware. The strengths of the paper are its scale of real patient data, the explicit local-development and privacy-preserving setup, the use of bootstrap confidence intervals, and the fabrication-rate validity checks. The main weakness is that the GPT-4o baseline is not specified, which makes the central comparative claim unauditable as reported. There is also an ambiguity about which split (validation vs. test) underlies the main results, and the abstract's ICD-10 numbers do not match Table 2. These issues are fixable but must be resolved before the conclusions can be accepted.
major comments (3)
- [Methods, 'Language Model Configurations' and 'Inference'] The GPT-4o baseline is not specified. The Methods state only that 'GPT-4o was used to establish a comparative benchmark representing large state of the art (SOTA) models,' with no prompt template, system message, output-format instructions, model version or date, temperature, sampling strategy, repetition penalty, or maximum token count, while the Phi-3 configurations are described in full. Because the headline conclusion is explicitly comparative ('Both fine-tuned models performed better or as well as GPT-4o'), the comparison is not auditable without this information. Please provide the exact GPT-4o prompt (ideally the same system prompt and output-format instructions used for the other configurations), the specific model version, all decoding settings, and any post-processing applied to its output, or explicitly weaken the comparative claim to what can be supported without that information.
- [Evaluation, 'Data Extraction and Processing' and Figure 3] It is unclear whether the main results in Table 2 and Figure 3 are computed on the held-out test set or on the validation set. The paper says the data were split 60/20/20 into training, validation, and test, and the inference section says the evaluation test set was used, but the bootstrap paragraph in Evaluation says 'The validation set is sampled with replacement (N = 39052)' for the confidence intervals shown in Figure 3. If the metrics are computed on the validation set, the held-out claim is compromised; if they are computed on the test set, the bootstrap text is incorrect. Additionally, N = 39,052 does not match 20% of 192,585 (which is 38,517). Please clarify which split produced the numbers in Table 2 and Figure 3 and correct the sample size.
- [Abstract and Table 2] The abstract reports ICD-10 recall and precision for the fine-tuned Phi-3 Medium as 72% and 72%, but Table 2 lists ICD-10 recall as 0.65 and precision as 0.72 for the same configuration. The CPT and modifier numbers in the abstract match Table 2, suggesting a typo, but this is a headline result and must be corrected or reconciled.
minor comments (7)
- [Results, 'Code Validity Analysis'] The phrase 'provided in Table X' should be replaced with the actual table number (Table 2).
- [Evaluation, equations] The precision and recall formulas contain unreadable special characters and should be typeset using standard mathematical notation.
- [Evaluation, F1 equation] The F1 formula is garbled; please replace it with a properly typeset expression and state explicitly that F1 is computed from the mean precision and mean recall rather than averaged per-case F1.
- [Background] The sentence 'augment and existing LLM' should read 'augment an existing LLM.'
- [Throughout] The model name is inconsistently capitalized as 'PHI-3' and 'Phi-3'; please use 'Phi-3' consistently.
- [Results, 'Data Extraction and Processing'] The size of the test set is not reported; please report the number of encounters in the training, validation, and test splits.
- [Evaluation, 'Format Consistency Analysis'] The 'ROUGE L Sum' metric is not standard in the cited reference; please define it or cite a source that defines it.
Circularity Check
No circular derivation: the evaluation is a supervised held-out benchmark; the only self-citation is non-load-bearing, and the undisclosed GPT-4o baseline is an auditability concern, not a circularity.
full rationale
The paper's central claim is that fine-tuned Phi-3 models match or beat GPT-4o on surgical billing-code generation. The supporting evidence is a supervised benchmark: models are trained on a 60% training split and evaluated on a 20% held-out test split, with recall and precision computed by comparing generated codes against the billing claims in that held-out split. No parameter is fitted to the test outcomes, and the reported metrics are empirical quantities computed from model outputs and ground-truth codes, not consequences of the training labels by construction. The RAG configuration retrieves similar examples from the training set and appends them to the prompt as in-context context; this is standard inference-time augmentation and does not incorporate the test claim's own answer into the input. The only self-citation (reference 39, Zaribafzadeh et al.) supports the general statement that the authors' prior institutional AI work serves as a model for integration under realistic constraints; it is not used to establish the accuracy numbers, to define the evaluation metric, or to rule out alternative designs, so it is not load-bearing. The undisclosed GPT-4o prompt and decoding settings are a legitimate experimental auditability concern because the headline comparison cannot be fully reproduced, but this is a missing control or fairness issue, not a circular reduction: the result is an empirical measurement that could in principle have gone either way and does not reduce to an identity or to a fitted parameter. Therefore I find no circular step and assign score 0.
Assumptions & free parameters
free parameters (7)
- LoRA rank =
64
- LoRA alpha =
16
- LoRA dropout =
0.1
- Max new tokens =
512
- Repetition penalty =
1.1
- RAG retrieval count (top-k) =
2
- Embedding model =
all-MiniLM-L6-v2
assumptions (4)
- domain assumption The institutional billing codes used as ground truth are accurate and complete.
- domain assumption Operative reports alone contain sufficient information to predict the assigned billing codes.
- domain assumption The 60/20/20 split creates independent training and test sets.
- ad hoc to paper The GPT-4o comparison used a prompt of comparable quality to the Phi-3 prompts.
Cite this review
Pith. "Pith review of Practical Design and Benchmarking of Generative AI Applications for Surgical Billing and Coding." pith.science (2026). https://pith.science/paper/Y2MXRA7R
@misc{pith2026250105479,
author = {Pith},
title = {Pith review of: Practical Design and Benchmarking of Generative AI Applications for Surgical Billing and Coding},
year = {2026},
howpublished = {\url{https://pith.science/paper/Y2MXRA7R}},
note = {Machine review of arXiv:2501.05479}
}
read the original abstract
Background: Healthcare has many manual processes that can benefit from automation and augmentation with Generative Artificial Intelligence (AI), the medical billing and coding process. However, current foundational Large Language Models (LLMs) perform poorly when tasked with generating accurate International Classification of Diseases, 10th edition, Clinical Modification (ICD-10-CM) and Current Procedural Terminology (CPT) codes. Additionally, there are many security and financial challenges in the application of generative AI to healthcare. We present a strategy for developing generative AI tools in healthcare, specifically for medical billing and coding, that balances accuracy, accessibility, and patient privacy. Methods: We fine tune the PHI-3 Mini and PHI-3 Medium LLMs using institutional data and compare the results against the PHI-3 base model, a PHI-3 RAG application, and GPT-4o. We use the post operative surgical report as input and the patients billing claim the associated ICD-10, CPT, and Modifier codes as the target result. Performance is measured by accuracy of code generation, proportion of invalid codes, and the fidelity of the billing claim format. Results: Both fine-tuned models performed better or as well as GPT-4o. The Phi-3 Medium fine-tuned model showed the best performance (ICD-10 Recall and Precision: 72%, 72%; CPT Recall and Precision: 77%, 79%; Modifier Recall and Precision: 63%, 64%). The Phi-3 Medium fine-tuned model only fabricated 1% of ICD-10 codes and 0.6% of CPT codes generated. Conclusions: Our study shows that a small model that is fine-tuned on domain-specific data for specific tasks using a simple set of open-source tools and minimal technological and monetary requirements performs as well as the larger contemporary consumer models.
Reference graph
Works this paper leans on
-
[1]
A study of generative large language model for medical research and healthcare
Peng C, Yang X, Chen A, et al. A study of generative large language model for medical research and healthcare. npj Digit Med 2023;6(1):1–10
work page 2023
-
[2]
Large language models in medicine
Thirunavukarasu AJ, Ting DSJ, Elangovan K, Gutierrez L, Tan TF, Ting DSW. Large language models in medicine. Nat Med 2023;29(8):1930–40
work page 2023
-
[3]
Using ChatGPT to write patient clinic letters
Ali SR, Dobbs TD, Hutchings HA, Whitaker IS. Using ChatGPT to write patient clinic letters. The Lancet Digital Health 2023;5(4):e179–81
work page 2023
-
[4]
ChatGPT: the future of discharge summaries? The Lancet Digital Health 2023;5(3):e107–8
Patel SB, Lam K. ChatGPT: the future of discharge summaries? The Lancet Digital Health 2023;5(3):e107–8
2023
-
[5]
Ethics of large language models in medicine and medical research
Li H, Moon JT, Purkayastha S, Celi LA, Trivedi H, Gichoya JW. Ethics of large language models in medicine and medical research. The Lancet Digital Health 2023;5(6):e333–5
work page 2023
-
[6]
Benefits, Limits, and Risks of GPT-4 as an AI Chatbot for Medicine
Lee P, Bubeck S, Petro J. Benefits, Limits, and Risks of GPT-4 as an AI Chatbot for Medicine. New England Journal of Medicine 2023;388(13):1233–9
work page 2023
-
[7]
Cascella M, Montomoli J, Bellini V, Bignami E. Evaluating the Feasibility of ChatGPT in Healthcare: An Analysis of Multiple Clinical and Research Scenarios. J Med Syst 2023;47(1):33
work page 2023
-
[8]
Key challenges for delivering clinical impact with artificial intelligence
Kelly CJ, Karthikesalingam A, Suleyman M, Corrado G, King D. Key challenges for delivering clinical impact with artificial intelligence. BMC Med 2019;17(1):195
work page 2019
Show all 47 references
-
[9]
GPT versus Resident Physicians — A Benchmark Based on Official Board Scores
Katz U, Cohen E, Shachar E, et al. GPT versus Resident Physicians — A Benchmark Based on Official Board Scores. NEJM AI 2024;1(5):AIdbp2300192
2024
-
[10]
Performance of ChatGPT on USMLE: Potential for AI-Assisted Medical Education Using Large Language Models [Internet]
Kung TH, Cheatham M, ChatGPT, et al. Performance of ChatGPT on USMLE: Potential for AI-Assisted Medical Education Using Large Language Models [Internet]. 2022 [cited 2024 Aug 12];2022.12.19.22283643. Available from: https://www.medrxiv.org/content/10.1101/2022.12.19.22283643v2
2022 doi
-
[11]
Large Language Models Are Poor Medical Coders — Benchmarking of Medical Code Querying
Soroush A, Glicksberg BS, Zimlichman E, et al. Large Language Models Are Poor Medical Coders — Benchmarking of Medical Code Querying. NEJM AI 2024;1(5):AIdbp2300040
2024
-
[12]
The shaky foundations of large language models and foundation models for electronic health records
Wornow M, Xu Y, Thapa R, et al. The shaky foundations of large language models and foundation models for electronic health records. npj Digit Med 2023;6(1):1–10
2023
-
[13]
A large language model for electronic health records
Yang X, Chen A, PourNejatian N, et al. A large language model for electronic health records. npj Digit Med 2022;5(1):1–9. 19
2022
-
[14]
Health system-scale language models are all-purpose prediction engines
Jiang LY, Liu XC, Nejatian NP, et al. Health system-scale language models are all-purpose prediction engines. Nature 2023;619(7969):357–62
2023
-
[15]
Scaling Down to Scale Up: A Guide to Parameter- Efficient Fine-Tuning [Internet]
Lialin V, Deshpande V, Rumshisky A. Scaling Down to Scale Up: A Guide to Parameter- Efficient Fine-Tuning [Internet]. arXiv.org. 2023 [cited 2024 Aug 12];Available from: https://arxiv.org/abs/2303.15647v1
2023 arXiv
-
[16]
Language Models are Few-Shot Learners [Internet]
Brown T, Mann B, Ryder N, et al. Language Models are Few-Shot Learners [Internet]. In: Advances in Neural Information Processing Systems. Curran Associates, Inc.; 2020 [cited 2024 Aug 12]. p. 1877–901.Available from: https://proceedings.neurips.cc/paper/2020/hash/1457c0d6bfcb4...
2020
-
[17]
Potential for GPT Technology to Optimize Future Clinical Decision-Making Using Retrieval-Augmented Generation
C W, J O, C W, H O, R C, D O. Potential for GPT Technology to Optimize Future Clinical Decision-Making Using Retrieval-Augmented Generation. Annals of biomedical engineering [Internet] 2024 [cited 2024 Aug 12];52(5). Available from: https://pubmed.ncbi.nlm.nih.gov/37530906/
2024
-
[18]
BioinspiredLLM: Conversational Large Language Model for the Mechanics of Biological and Bio-Inspired Materials
Luu RK, Buehler MJ. BioinspiredLLM: Conversational Large Language Model for the Mechanics of Biological and Bio-Inspired Materials. Adv Sci (Weinh) 2023;11(10):2306724
2023
-
[19]
Retrieval augmentation of large language models for lay language generation
Guo Y, Qiu W, Leroy G, Wang S, Cohen T. Retrieval augmentation of large language models for lay language generation. Journal of Biomedical Informatics 2024;149:104580
2024
-
[20]
Empirical Analysis of the Strengths and Weaknesses of PEFT Techniques for LLMs [Internet]
Pu G, Jain A, Yin J, Kaplan R. Empirical Analysis of the Strengths and Weaknesses of PEFT Techniques for LLMs [Internet]. 2023 [cited 2024 Aug 12];Available from: http://arxiv.org/abs/2304.14999
2023 arXiv
-
[21]
Few-Shot Parameter-Efficient Fine-Tuning is Better and Cheaper than In-Context Learning [Internet]
Liu H, Tam D, Muqeeth M, et al. Few-Shot Parameter-Efficient Fine-Tuning is Better and Cheaper than In-Context Learning [Internet]. 2022 [cited 2024 Aug 12];Available from: http://arxiv.org/abs/2205.05638
2022 arXiv
-
[22]
Lost in the Middle: How Language Models Use Long Contexts [Internet]
Liu NF, Lin K, Hewitt J, et al. Lost in the Middle: How Language Models Use Long Contexts [Internet]. 2023 [cited 2024 Aug 12];Available from: http://arxiv.org/abs/2307.03172
2023 arXiv
-
[23]
Towards Medical Billing Automation: NLP for Outpatient Clinician Note Classification [Internet]
Crowson MG, Alsentzer E, Fiskio J, Bates DW. Towards Medical Billing Automation: NLP for Outpatient Clinician Note Classification [Internet]. 2023 [cited 2024 Aug 12];2023.07.07.23292367. Available from: https://www.medrxiv.org/content/10.1101/2023.07.07.23292367v1
2023 doi
-
[24]
Phi-3 Technical Report: A Highly Capable Language Model Locally on Your Phone [Internet]
Abdin M, Jacobs SA, Awan AA, et al. Phi-3 Technical Report: A Highly Capable Language Model Locally on Your Phone [Internet]. 2024 [cited 2024 Aug 12];Available from: http://arxiv.org/abs/2404.14219 20
2024 arXiv
-
[25]
Introducing Phi-3: Redefining what’s possible with SLMs [Internet]
Bilenko M. Introducing Phi-3: Redefining what’s possible with SLMs [Internet]. Microsoft Azure Blog. 2024 [cited 2024 Aug 12];Available from: https://azure.microsoft.com/en- us/blog/introducing-phi-3-redefining-whats-possible-with-slms/
2024
-
[26]
Link and code: Fast indexing with graphs and compact regression codes [Internet]
Douze M, Sablayrolles A, Jégou H. Link and code: Fast indexing with graphs and compact regression codes [Internet]. arXiv.org. 2018 [cited 2024 Sep 5];Available from: https://arxiv.org/abs/1804.09996v2
2018 arXiv
-
[27]
Billion-scale similarity search with GPUs [Internet]
Johnson J, Douze M, Jégou H. Billion-scale similarity search with GPUs [Internet]. arXiv.org. 2017 [cited 2024 Sep 5];Available from: https://arxiv.org/abs/1702.08734v1
2017 arXiv
-
[28]
Sentence-BERT: Sentence Embeddings using Siamese BERT- Networks [Internet]
Reimers N, Gurevych I. Sentence-BERT: Sentence Embeddings using Siamese BERT- Networks [Internet]. arXiv.org. 2019 [cited 2024 Sep 5];Available from: https://arxiv.org/abs/1908.10084v1
2019 arXiv
-
[29]
QLoRA: Efficient Finetuning of Quantized LLMs [Internet]
Dettmers T, Pagnoni A, Holtzman A, Zettlemoyer L. QLoRA: Efficient Finetuning of Quantized LLMs [Internet]. 2023 [cited 2024 Aug 13];Available from: http://arxiv.org/abs/2305.14314
2023 arXiv
-
[30]
FlashAttention-2: Faster Attention with Better Parallelism and Work Partitioning [Internet]
Dao T. FlashAttention-2: Faster Attention with Better Parallelism and Work Partitioning [Internet]. 2023 [cited 2024 Aug 13];Available from: http://arxiv.org/abs/2307.08691
2023 arXiv
-
[31]
ZeRO: Memory Optimizations Toward Training Trillion Parameter Models [Internet]
Rajbhandari S, Rasley J, Ruwase O, He Y. ZeRO: Memory Optimizations Toward Training Trillion Parameter Models [Internet]. 2020 [cited 2024 Sep 6];Available from: http://arxiv.org/abs/1910.02054
2020 arXiv
-
[32]
ZeRO-Offload: Democratizing Billion-Scale Model Training [Internet]
Ren J, Rajbhandari S, Aminabadi RY, et al. ZeRO-Offload: Democratizing Billion-Scale Model Training [Internet]. 2021 [cited 2024 Sep 6];Available from: http://arxiv.org/abs/2101.06840
2021 arXiv
-
[33]
ZeRO-Infinity: Breaking the GPU Memory Wall for Extreme Scale Deep Learning [Internet]
Rajbhandari S, Ruwase O, Rasley J, Smith S, He Y. ZeRO-Infinity: Breaking the GPU Memory Wall for Extreme Scale Deep Learning [Internet]. 2021 [cited 2024 Sep 6];Available from: http://arxiv.org/abs/2104.07857
2021 arXiv
-
[34]
A Thorough Examination of Decoding Methods in the Era of LLMs [Internet]
Shi C, Yang H, Cai D, et al. A Thorough Examination of Decoding Methods in the Era of LLMs [Internet]. 2024 [cited 2024 Aug 13];Available from: http://arxiv.org/abs/2402.06925
2024 arXiv
-
[35]
Diagnosis code assignment: models and evaluation metrics
Perotte A, Pivovarov R, Natarajan K, Weiskopf N, Wood F, Elhadad N. Diagnosis code assignment: models and evaluation metrics. J Am Med Inform Assoc 2014;21(2):231–7
2014
-
[36]
3M Inside Angle
About accuracy...part 2 [Internet]. 3M Inside Angle. [cited 2024 Sep 6];Available from: https://insideangle.3m.com/his/blog-post/about-accuracy-part-2/
2024
-
[37]
ROUGE: A Package for Automatic Evaluation of Summaries [Internet]
Lin C-Y. ROUGE: A Package for Automatic Evaluation of Summaries [Internet]. In: Text Summarization Branches Out. Barcelona, Spain: Association for Computational Linguistics; 2004 [cited 2024 Aug 13]. p. 74–81.Available from: https://aclanthology.org/W04-1013 21
2004
-
[38]
METEOR: An Automatic Metric for MT Evaluation with Improved Correlation with Human Judgments [Internet]
Banerjee S, Lavie A. METEOR: An Automatic Metric for MT Evaluation with Improved Correlation with Human Judgments [Internet]. In: Goldstein J, Lavie A, Lin C-Y, Voss C, editors. Proceedings of the ACL Workshop on Intrinsic and Extrinsic Evaluation Measures for Machine Translat...
2005
-
[39]
Development, Deployment, and Implementation of a Machine Learning Surgical Case Length Prediction Model and Prospective Evaluation
Zaribafzadeh H, Webster WL, Vail CJ, et al. Development, Deployment, and Implementation of a Machine Learning Surgical Case Length Prediction Model and Prospective Evaluation. Annals of Surgery 2023;278(6):890
2023
-
[40]
Automated clinical coding: what, why, and where we are? NPJ Digit Med 2022;5(1):159
Dong H, Falis M, Whiteley W, et al. Automated clinical coding: what, why, and where we are? NPJ Digit Med 2022;5(1):159
2022
-
[41]
A systematic literature review of automated clinical coding and classification systems
Stanfill MH, Williams M, Fenton SH, Jenders RA, Hersh WR. A systematic literature review of automated clinical coding and classification systems. J Am Med Inform Assoc 2010;17(6):646–51
2010
-
[42]
3M Inside Angle
CAC Exact: A new CAC system performance metric [Internet]. 3M Inside Angle. [cited 2024 Sep 6];Available from: https://insideangle.3m.com/his/blog-post/cac-exact-a-new-cac- system-performance-metric/
2024
-
[43]
Read, Attend, and Code: Pushing the Limits of Medical Codes Prediction from Clinical Notes by Machines [Internet]
Kim B-H, Ganapathi V. Read, Attend, and Code: Pushing the Limits of Medical Codes Prediction from Clinical Notes by Machines [Internet]. arXiv.org. 2021 [cited 2024 Sep 6];Available from: https://arxiv.org/abs/2107.10650v1
2021 arXiv
-
[44]
Injecting New Knowledge into Large Language Models via Supervised Fine-Tuning [Internet]
Mecklenburg N, Lin Y, Li X, et al. Injecting New Knowledge into Large Language Models via Supervised Fine-Tuning [Internet]. 2024 [cited 2024 Aug 13];Available from: http://arxiv.org/abs/2404.00213
2024 arXiv
-
[45]
Parameter-Efficient Fine-Tuning Methods for Pretrained Language Models: A Critical Review and Assessment [Internet]
Xu L, Xie H, Qin S-ZJ, Tao X, Wang FL. Parameter-Efficient Fine-Tuning Methods for Pretrained Language Models: A Critical Review and Assessment [Internet]. 2023 [cited 2024 Aug 12];Available from: http://arxiv.org/abs/2312.12148
2023 arXiv
-
[46]
Efficient Memory Management for Large Language Model Serving with PagedAttention [Internet]
Kwon W, Li Z, Zhuang S, et al. Efficient Memory Management for Large Language Model Serving with PagedAttention [Internet]. 2023 [cited 2024 Sep 6];Available from: http://arxiv.org/abs/2309.06180
2023 arXiv
-
[47]
Journal of AHIMA
Are LLMs Coming for Coding? Yes, and Medical Coders Should Prepare [Internet]. Journal of AHIMA. [cited 2024 Sep 6];Available from: https://journal.ahima.org/page/are-llms- coming-for-coding-yes-and-medical-coders-should-prepare
2024
Reviewed August 10, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.