Pith. sign in

REVIEW 2 cited by

High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1511.03539 v1 pith:YXKTECLO submitted 2015-11-11 physics.ins-det

classification physics.ins-det
keywords electrondetectorarraypixelscanningallowingdatadynamic
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We describe a hybrid pixel array detector (EMPAD - electron microscope pixel array detector) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128 x 128 pixel detector consists of a 500 um thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit (ASIC). The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition (DAQ) system, and preliminary results from experiments with 80 to 200 keV electron beams.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Guided progressive reconstructive imaging: a new quantization-based framework for low-dose, high-throughput and real-time analytical ptychography

    physics.app-ph 2025-12 conditional novelty 6.0 of 10

    Ptychographic phase reconstruction can be decomposed into a sum of precomputed single-electron contributions, enabling linear-complexity, event-wise direct phase retrieval.

  2. Benchmarking analytical electron ptychography methods for the low-dose imaging of beam-sensitive materials

    physics.app-ph 2025-01 conditional novelty 6.0 of 10

    Analytical ptychography can image beam-sensitive specimens at very low electron doses, with dose requirement proportional to the reconstructed frequency surface and comparable per-frequency dose efficiency across WDD,...

Pith tools