Mechanical quality factor of a sapphire fiber at cryogenic temperatures

General Relativity and Quantum Cosmology · Submitted 27 Jul 2000

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim Consequently, we confirm that pendulum thermal noise of cryogenic mirrors used for gravitational wave detectors can be reduced by the sapphire fiber suspension.

how it is stated · asserted 0.87 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv IDgr-qc/0007071 (version 1)
Pith IDFLCDRSX2, Pith's permanent record of this paper and its review
CitationA. Yamamoto, D. Tatsumi, K. Kuroda, M. Ohashi, S. Miyoki, T. Shintomi, T. Suzuki, T. Tomaru, T. Uchiyama. "Mechanical quality factor of a sapphire fiber at cryogenic temperatures." arXiv:gr-qc/0007071 (2000). https://pith.science/paper/FLCDRSX2
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13-20260917 via OpenRouter, question bank abstract-p1-20260923, 2026-09-23: 1 request, 2,319 input tokens, $0.0001 reported.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.06 · human participants 0.02 · controlled comparison 0.04 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.10 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

A mechanical quality factor of $1.1 \times 10^{7}$ was obtained for the 199 Hz bending vibrational mode in a monocrystalline sapphire fiber at 6 K. Consequently, we confirm that pendulum thermal noise of cryogenic mirrors used for gravitational wave detectors can be reduced by the sapphire fiber suspension.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 A mechanical quality factor of $1.1 \times 10^{7}$ was obtained for the 199 Hz bending vibrational mode in a monocrystalline sapphire fiber at 6 K. result 1.00 0.91 0.25 asserted 1.00
s1 Consequently, we confirm that pendulum thermal noise of cryogenic mirrors used for gravitational wave detectors can be reduced by the sapphire fiber suspension. interpretation 1.00 0.58 0.86 asserted 0.87

What kind of paper the classifier reports this is: empirical study 1.00 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

A mechanical quality factor of $1.1 \times 10^{7}$ was obtained for the 199 Hz bending vibrational mode in a monocrystalline sapphire fiber at 6 K. Consequently, we confirm that pendulum thermal noise of cryogenic mirrors used for gravitational wave detectors can be reduced by the sapphire fiber suspension.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.