Pith. sign in

REVIEW 2 cited by

A Method of Alignment of the Plastic Scintillator Detector of DAMPE

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1808.05720 v2 pith:ZRBNCD45 submitted 2018-08-17 astro-ph.IM astro-ph.HE

A Method of Alignment of the Plastic Scintillator Detector of DAMPE

classification astro-ph.IM astro-ph.HE
keywords alignmentdetectorchargeeventsmethodbarsdampefully
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The Plastic Scintillator Detector (PSD) of the DArk Matter Particle Explorer (DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto detector for gamma-ray identification. In order to fully exploit the charge identification potential of the PSD and to enhance its capability to identify the gamma ray events, we develop a PSD detector alignment method. The path length of a given track in the volume of a PSD bar is derived taking into account the shift and rotation alignment corrections. By examining energy spectra of corner-passing events and fully contained events, position shifts and rotations of all PSD bars are obtained, and found to be on average about 1mm and 0.0015 radian respectively. To validate the alignment method, we introduce the artificial shifts and rotations of PSD bars in the detector simulation. These shift and rotation parameters can be recovered successfully by the alignment procedure. As a result of the PSD alignment procedure, the charge resolution of the PSD is improved from $4\%$ to $8\%$ depending on the nuclei.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Charge-dependent spectral softenings of primary cosmic-rays below the knee

    astro-ph.HE 2025-11 conditional novelty 7.0

    Direct measurements reveal charge-dependent spectral softenings in primary cosmic rays at a common rigidity of ~15 TV, rejecting mass-dependent softening at >99.999% confidence.

  2. The on-orbit calibration of DArk Matter Particle Explorer

    astro-ph.IM 2019-07 unverdicted novelty 3.0

    DAMPE sub-detectors (PSD, STK, BGO, NUD) are calibrated on-orbit with cosmic rays and gamma sources, with results showing stability over nearly two years.