Pith. sign in

REVIEW 2 cited by

Copper electroplating for background suppression in the NEWS-G experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2008.03153 v2 pith:K2BEN224 submitted 2020-08-07 physics.ins-det astro-ph.IMhep-ex

Copper electroplating for background suppression in the NEWS-G experiment

classification physics.ins-det astro-ph.IMhep-ex
keywords copperdetectorexperimentmeasurementsnews-grare-eventsearchesbackground
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
abstract

New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$\mu$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $\mu$Bq/kg (<0.24 $\mu$Bq/kg) and <0.26 $\mu$Bq/kg (<0.11 $\mu$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Design of high-strength, radiopure, electroformed copper-based alloys for rare-event searches: Impact of layer configuration on heat treatments

    physics.ins-det 2025-09 conditional novelty 4.0

    Simulations predict that specific Cr/Cu and Cr/Ti layer thicknesses homogenize into radiopure CuCr and CrTi alloys within practical heat-treatment times, but experimental validation is still pending.

  2. Titanium for rare-event searches: Hydrofluoric acid-free etching

    physics.ins-det 2025-08 conditional novelty 4.0

    Titanium can be etched with 40% sulfuric acid at 40°C, removing about 3.7 µm of surface material and eliminating visible surface contaminants, offering an HF-free preparation route for rare-event detector materials.