Pith. sign in

REVIEW 3 cited by

Calibrating VLBI Polarization Data Using GPCAL. I. Frequency-Dependent Calibration

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2310.03242 v1 pith:CSW7CAZV submitted 2023-10-05 astro-ph.IM

Calibrating VLBI Polarization Data Using GPCAL. I. Frequency-Dependent Calibration

classification astro-ph.IM
keywords polarizationcalibrationdatainstrumentalfrequency-dependentmethodsetsvery
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

In this series of papers, we present new methods of frequency- and time-dependent instrumental polarization calibration for Very Long Baseline Interferometry (VLBI). In most existing calibration tools and pipelines, it has been assumed that instrumental polarization is constant over frequency within the instrument bandwidth and over time. The assumption is not always true and may prevent an accurate calibration, which can result in degradation of the quality of linear polarization images. In this paper, we present a method of frequency-dependent instrumental polarization calibration that is implemented in GPCAL, a recently developed polarization calibration pipeline. The method is tested using simulated data sets generated from real Very Long Baseline Array (VLBA) data. We present the results of appyling the method to real VLBA data sets observed at 15 and 43 GHz. We were able to eliminate significant variability in cross-hand visibilities over frequency that is caused by frequency-dependent instrumental polarization. As a result of the calibration, linear polarization images were slightly to modestly improved as compared to those obtained without frequency-dependent instrumental polarization calibration. We discuss the reason for the minor impact of frequency-dependent instrumental polarization calibration on existing VLBA data sets and prospects for applying the method to future VLBI data sets, which are expected to provide very large bandwidths.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. VAPOLA -- A multi-year, multi-band polarization survey of AGN and Sgr A* at mm wavelengths with ALMA I. Survey Overview and Science-Ready Archival Products

    astro-ph.GA 2026-07 accept novelty 6.0

    An automated pipeline and web portal deliver science-ready, full-polarization ALMA data products from VLBI campaigns for AGN and Sgr A* across Bands 3, 6, and 7.

  2. VAPOLA -- A multi-year, multi-band polarization survey of AGN and Sgr A* at mm wavelengths with ALMA I. Survey Overview and Science-Ready Archival Products

    astro-ph.GA 2026-07 conditional novelty 6.0

    VAPOLA releases multi-epoch multi-band ALMA full-Stokes products and polarimetric fits for AGN and Sgr A* via an automated pipeline and web portal.

  3. Dynamics and geometry of the inner sub-parsec-scale jet in 3C 279 observed with the Event Horizon Telescope

    astro-ph.GA 2026-07 conditional novelty 5.0

    EHT 2021 images of 3C 279 reveal an intrinsic, sideways-elongated jet base whose components move at apparent speeds up to 10c, implying a sub-parsec bend toward the observer and viewing angles below one degree.