Pith. sign in

REVIEW 1 cited by

High-volume tunable resonator for axion searches above 7 GHz

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2402.01060 v3 pith:QYEO6LTE submitted 2024-02-01 physics.ins-det astro-ph.IMhep-ex

High-volume tunable resonator for axion searches above 7 GHz

classification physics.ins-det astro-ph.IMhep-ex
keywords axiontunablecavity-basedfactorfuturehaloscopelambdameasurements
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We present results from the first experimental demonstration of a tunable thin-shell axion haloscope. This novel geometry decouples the overall volume of the cavity-based resonator from its resonant frequency, thereby evading the steep sensitivity degradation at high-frequencies. An aluminum $2.6$ L ($41$ $\lambda^3$) prototype which tunes from $7.1$ to $8.0$ GHz was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable $\mathrm{TM}$$_{010}$ mode is clearly identified with a room temperature quality factor, $Q$, of $\sim$$5,000$. The on-resonance $E$-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of $0.57$ across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume $V\gg\lambda^3$. We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the post-inflationary axion parameter space ($\sim$$4$ to $\sim$$30$ GHz) at DFSZ sensitivity.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The VORTEX cavity for the RADES axion haloscope

    physics.ins-det 2026-07 conditional novelty 5.0

    A split-cylinder axion haloscope tunes continuously from 9 to 8.2 GHz with modest Q loss, operates at millikelvin temperatures, and its TM010 field profile passes bead-pull verification.