REVIEW 4 cited by
Dia-LLaMA: Towards Large Language Model-driven CT Report Generation
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
Medical report generation has achieved remarkable advancements yet has still been faced with several challenges. First, the inherent imbalance in the distribution of normal and abnormal cases may lead models to exhibit a biased focus on normal samples, resulting in unreliable diagnoses. Second, the frequent occurrence of common template sentences in the reports may overwhelm the critical abnormal information. Moreover, existing works focus on 2D chest X-rays, leaving CT report generation underexplored due to the high-dimensional nature of CT images and the limited availability of CT-report pairs. Recently, LLM has shown a great ability to generate reliable answers with appropriate prompts, which shed light on addressing the aforementioned challenges. In this paper, we propose Dia-LLaMA, a framework to adapt the LLaMA2-7B for CT report generation by incorporating diagnostic information as guidance prompts. Considering the high dimension of CT, we leverage a pre-trained ViT3D with perceiver to extract the visual information. To tailor the LLM for report generation and emphasize abnormality, we extract additional diagnostic information by referring to a disease prototype memory bank, which is updated during training to capture common disease representations. Furthermore, we introduce disease-aware attention to enable the model to adjust attention for different diseases. Experiments on the chest CT dataset demonstrated that our proposed method outperformed previous methods and achieved state-of-the-art on both clinical efficacy performance and natural language generation metrics. The code will be made publically available.
Forward citations
Cited by 4 Pith papers
-
Disorder-induced stress-flow misalignment in soft glassy materials revealed using multi-directional shear
Soft glassy materials show a transient stress response orthogonal to a newly applied shear direction, which a mesoscopic elasto-plastic model attributes to local yield-stress disorder.
-
LLM-driven Medical Report Generation via Communication-efficient Heterogeneous Federated Learning
FedMRG trains federated LLM-based report generators with low-rank adapters, diagnosis prompts, and dual-adapter mutual boosting, beating baselines on chest X-ray benchmarks.
-
HSENet: Hybrid Spatial Encoding Network for 3D Medical Vision-Language Understanding
HSENet improves 3D CT vision-language understanding by combining global and local 3D encoders with a centroid-based spatial token compressor, posting state-of-the-art results on CT-RATE and RadGenome-ChestCT.
-
Region-Aware Multimodal Large Language Model via SlowFast Tokenization and Pseudo-Mask Guidance for 3D CT Report Generation
MedRegion-CT integrates region-representative tokens, mask-driven segmentation tokens, and patient-specific attribute prompts into a multimodal LLM, reporting state-of-the-art scores on RadGenome-Chest CT report generation.
Discussion (0). Continue with ORCID to comment.