Pith. sign in

REVIEW 1 cited by

Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv gr-qc/0208051 v1 pith:DH7MYEA2 submitted 2002-08-18 gr-qc

Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector

classification gr-qc
keywords sagnacspeedgravitational-waveinterferometeropticalquantumsameband
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

According to quantum measurement theory, "speed meters" -- devices that measure the momentum, or speed, of free test masses -- are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sagnac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by P. Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sagnac, as for other speed meters. With squeezed vacuum (squeeze factor $e^{-2R} = 0.1$) injected into its dark port, the recycled Sagnac can beat the SQL by a factor $ \sqrt{10} \simeq 3$ over the frequency band $10 {\rm Hz} \alt f \alt 150 {\rm Hz}$ using the same circulating power $I_c\sim 820$ kW as is used by the (quantum limited) second-generation Advanced LIGO interferometers -- if other noise sources are made sufficiently small. It is concluded that the Sagnac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO).

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Improving calibration accuracy with torque coupled gravity field calibrator for sub-Hz gravitational wave observation in CHRONOS

    gr-qc 2026-02 conditional novelty 6.0

    A torque-coupled gravity calibrator for CHRONOS is calculated to give a calibration SNR density of 4.25e3 at 1 Hz with 0.24% fractional systematic uncertainty.