Monolithic scintillator tracker with embedded scatterers achieves 1.47 mm position resolution below the 10 mm readout pitch via light-yield distribution, validated in positron beam test.
hub
Recent developments in G EANT 4
13 Pith papers cite this work, alongside 3,592 external citations. Polarity classification is still indexing.
hub tools
citation-role summary
citation-polarity summary
representative citing papers
A LoRA-adapted conditional diffusion surrogate for electromagnetic calorimeter showers matches key observables within 2% RMSE and reproduces directional trends in design-utility gradients.
HIMoC devices produce threshold-voltage shifts from 24.8 MeV/u heavy ions that are modeled as Gaussian charge-loss profiles and scale linearly with fluence times LET times area.
Graph neural networks can identify and remove unwanted beam background depositions in the Belle II calorimeter to improve hadronic clustering and reduce fake photon clusters.
Unsupervised domain adaptation via feature alignment raises radioisotope identification accuracy on real LaBr3 gamma spectra from 0.754 to 0.904 for models trained only on synthetic data.
CERES is a dedicated cryogenic experiment to directly characterize position-dependent variations in the energy response of TeO2 bolometers.
Geant4 now supports configuring optical simulations entirely through extended text-based geometry descriptions without requiring C++ programming.
Optical broadening in glass GEMs increases simulated particle track intensity and width by up to 26% and 31%, explaining larger-than-expected signals in GEM-based OTPCs.
New cross sections for natC(n,p) and natC(n,d) up to 25 MeV are higher than evaluations and agree with TALYS-2.0 after model-assisted corrections for excited states.
CMS measures the W boson mass as 80360.2 ± 9.9 MeV from 2016 data, consistent with the Standard Model prediction.
The ratio |G_E|/|G_M| of neutron timelike form factors averages 1.21 ± 0.13 across eight energy points from 1.89 to 2.00 GeV.
Neural network reconstructs cosmic-ray trajectories to better than 1.4° angular resolution and separates charges to >95% accuracy for Z≤8 using Geant4-simulated data for the RadMap Telescope.
citing papers explorer
-
Design and Performance of a Monolithic Plastic Scintillator Tracker with Embedded Scatterers
Monolithic scintillator tracker with embedded scatterers achieves 1.47 mm position resolution below the 10 mm readout pitch via light-yield distribution, validated in positron beam test.
-
Differentiable Surrogate for Detector Simulation and Design with Diffusion Models
A LoRA-adapted conditional diffusion surrogate for electromagnetic calorimeter showers matches key observables within 2% RMSE and reproduces directional trends in design-utility gradients.
-
A Heavy Ion Monitor on a Chip Based on a Non-Volatile Memory Architecture -- Part II: Device Characterization & Modeling
HIMoC devices produce threshold-voltage shifts from 24.8 MeV/u heavy ions that are modeled as Gaussian charge-loss profiles and scale linearly with fluence times LET times area.
-
CERES: A Cryogenic Experiment to Reconstruct Energy Systematics in TeO$_{2}$ bolometers
CERES is a dedicated cryogenic experiment to directly characterize position-dependent variations in the energy response of TeO2 bolometers.
-
Optical effects in Gaseous Electron Multipliers (GEMs)
Optical broadening in glass GEMs increases simulated particle track intensity and width by up to 26% and 31%, explaining larger-than-expected signals in GEM-based OTPCs.
- Exploring the Boundaries of Differentiable Radiation Transport and Detector Simulation