Pith. sign in

REVIEW

WattScope: Non-intrusive Application-level Power Disaggregation in Datacenters

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.12612 v1 pith:B3MTY2DT submitted 2023-09-22 cs.DC cs.CYcs.PF

WattScope: Non-intrusive Application-level Power Disaggregation in Datacenters

classification cs.DC cs.CYcs.PF
keywords powerapplicationsconsumptiondatacenterenergymonitoringwattscopeapplication-level
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

Datacenter capacity is growing exponentially to satisfy the increasing demand for emerging computationally-intensive applications, such as deep learning. This trend has led to concerns over datacenters' increasing energy consumption and carbon footprint. The basic prerequisite for optimizing a datacenter's energy- and carbon-efficiency is accurately monitoring and attributing energy consumption to specific users and applications. Since datacenter servers tend to be multi-tenant, i.e., they host many applications, server- and rack-level power monitoring alone does not provide insight into their resident applications' energy usage and carbon emissions. At the same time, current application-level energy monitoring and attribution techniques are intrusive: they require privileged access to servers and require coordinated support in hardware and software, which is not always possible in cloud. To address the problem, we design WattScope, a system for non-intrusively estimating the power consumption of individual applications using external measurements of a server's aggregate power usage without requiring direct access to the server's operating system or applications. Our key insight is that, based on an analysis of production traces, the power characteristics of datacenter workloads, e.g., low variability, low magnitude, and high periodicity, are highly amenable to disaggregation of a server's total power consumption into application-specific values. WattScope adapts and extends a machine learning-based technique for disaggregating building power and applies it to server- and rack-level power meter measurements in data centers. We evaluate WattScope's accuracy on a production workload and show that it yields high accuracy, e.g., often <10% normalized mean absolute error, and is thus a potentially useful tool for datacenters in externally monitoring application-level power usage.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.