Pith. sign in

REVIEW 3 cited by

MEDIC: Comprehensive Evaluation of Leading Indicators for LLM Safety and Utility in Clinical Applications

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2409.07314 v4 pith:7XPFRXXT submitted 2024-09-11 cs.CL cs.AI

MEDIC: Comprehensive Evaluation of Leading Indicators for LLM Safety and Utility in Clinical Applications

classification cs.CL cs.AI
keywords clinicalevaluationacrossindicatorsmedicsafetystaticcapability
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
read the original abstract

While Large Language Models (LLMs) achieve superhuman performance on standardized medical licensing exams, these static benchmarks have become saturated and increasingly disconnected from the functional requirements of clinical workflows. To bridge the gap between theoretical capability and verified utility, we introduce MEDIC, a comprehensive evaluation framework establishing leading indicators of clinical LLM competence across five dimensions. These upfront indicators reveal cross-benchmark capability gaps, such as the divergence between static knowledge retrieval and functional execution, that inform model selection before costly deployment-based evaluation. Beyond standard question-answering, we assess operational capabilities using deterministic execution protocols and a novel Cross-Examination Framework (CEF), which quantifies information fidelity and hallucination rates without reliance on reference texts. Our evaluation across a heterogeneous task suite exposes critical performance trade-offs: we identify a significant knowledge-execution gap, where proficiency in static retrieval does not predict success in operational tasks such as clinical calculation or SQL generation. Furthermore, we observe a divergence between passive safety (refusal) and active safety (error detection), revealing that models fine-tuned for high refusal rates often fail to reliably audit clinical documentation for factual accuracy. These findings demonstrate that no single architecture dominates across all dimensions, highlighting the necessity of a portfolio approach to clinical model deployment. We accompany this work with a publicly available MEDIC leaderboard at https://hf.co/spaces/m42-health/MEDIC-Benchmark.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Evaluating Patient Safety Risks in Generative AI: Development and Validation of a FMECA Framework for Generated Clinical Content

    cs.CY 2026-04 unverdicted novelty 7.0

    A novel FMECA-based framework was developed and validated for systematic assessment of patient safety risks in LLM-generated clinical discharge summaries, demonstrating moderate-to-substantial inter-rater agreement an...

  2. PatientAgentBench: A Benchmark Framework for Evaluating Patient-Facing Health AI Agents

    cs.AI 2026-07 conditional novelty 6.0

    A clinician-validated benchmark for patient-facing health AI agents shows that even frontier models fail triage in up to a quarter of realistic tool-using conversations.

  3. Development and Preliminary Evaluation of a Domain-Specific Large Language Model for Tuberculosis Care in South Africa

    cs.CL 2026-03 unverdicted novelty 3.0

    A domain-specific LLM for TB care in South Africa, created by fine-tuning BioMistral-7B with QLoRA and GraphRAG on local guidelines, shows improved contextual alignment over the base model.