REVIEW
An Efficient Medical Image Classification Method Based on a Lightweight Improved ConvNeXt-Tiny Architecture
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
An Efficient Medical Image Classification Method Based on a Lightweight Improved ConvNeXt-Tiny Architecture
read the original abstract
Intelligent analysis of medical imaging plays a crucial role in assisting clinical diagnosis. However, achieving efficient and high-accuracy image classification in resource-constrained computational environments remains challenging. This study proposes a medical image classification method based on an improved ConvNeXt-Tiny architecture. Through structural optimization and loss function design, the proposed method enhances feature extraction capability and classification performance while reducing computational complexity. Specifically, the method introduces a dual global pooling (Global Average Pooling and Global Max Pooling) feature fusion strategy into the ConvNeXt-Tiny backbone to simultaneously preserve global statistical features and salient response information. A lightweight channel attention module, termed Squeeze-and-Excitation Vector (SEVector), is designed to improve the adaptive allocation of channel weights while minimizing parameter overhead. Additionally, a Feature Smoothing Loss is incorporated into the loss function to enhance intra-class feature consistency and suppress intra-class variance. Under CPU-only conditions (8 threads), the method achieves a maximum classification accuracy of 89.10% on the test set within 10 training epochs, exhibiting a stable convergence trend in loss values. Experimental results demonstrate that the proposed method effectively improves medical image classification performance in resource-limited settings, providing a feasible and efficient solution for the deployment and promotion of medical imaging analysis models.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.