Pith. sign in

REVIEW 2 cited by

Study of scattered light in the main arms of the Einstein Telescope gravitational wave detector

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2307.14104 v1 pith:CKHJTO5C submitted 2023-07-26 gr-qc astro-ph.IM

classification gr-qcastro-ph.IM
keywords lightscatterednoisearmsbafflecalculationsdetectoreinstein
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We present an estimation of the noise induced by scattered light inside the main arms of the Einstein Telescope (ET) gravitational wave detector. Both ET configurations for high- and low-frequency interferometers are considered, for which we propose baffle layouts. The level of scattered light and the ET laser beam clipping losses are intimately related to the baffle inner aperture. We discuss how this translates into minimum requirements on the vacuum pipe radius, a critical parameter in the ET design. The noise estimations are computed using analytical calculations complemented with numerical tools, and depend on a number of baseline parameters we use as input in the calculations. We conclude that the scattered light noise can be maintained at acceptable levels such that does not compromise the ET performance, provided some requirements are met.

Discussion (0). Sign in to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Optomechanical transfer factors for scattered light noise estimations in the beamtubes of ground-based gravitational wave detectors

    gr-qc 2026-07 conditional novelty 6.0 of 10

    Scattered-light noise coupling to strain readout is derived as full optomechanical transfer factors, recovering legacy models only in phase-dominated regimes and substantially revising Einstein Telescope low-frequency...

  2. New modeling of the stray light noise in the main arms of the Einstein Telescope

    physics.ins-det 2025-06 conditional novelty 5.0 of 10

    Stray light noise in Einstein Telescope arms is predicted to stay below the safety margin in ideal conditions, but beam offsets above 4 to 7 cm, tilts above 8 microradians, or strong point absorbers could breach it.

Pith tools