Pith. sign in

REVIEW 1 cited by

RS-MOCO: A deep learning-based topology-preserving image registration method for cardiac T1 mapping

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2410.11651 v1 pith:WTJY3XKO submitted 2024-10-15 cs.CV cs.AIcs.LG

classification cs.CVcs.AIcs.LG
keywords registrationcardiacconstraintimagemappingconsistencycorrectionmotion
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Cardiac T1 mapping can evaluate various clinical symptoms of myocardial tissue. However, there is currently a lack of effective, robust, and efficient methods for motion correction in cardiac T1 mapping. In this paper, we propose a deep learning-based and topology-preserving image registration framework for motion correction in cardiac T1 mapping. Notably, our proposed implicit consistency constraint dubbed BLOC, to some extent preserves the image topology in registration by bidirectional consistency constraint and local anti-folding constraint. To address the contrast variation issue, we introduce a weighted image similarity metric for multimodal registration of cardiac T1-weighted images. Besides, a semi-supervised myocardium segmentation network and a dual-domain attention module are integrated into the framework to further improve the performance of the registration. Numerous comparative experiments, as well as ablation studies, demonstrated the effectiveness and high robustness of our method. The results also indicate that the proposed weighted image similarity metric, specifically crafted for our network, contributes a lot to the enhancement of the motion correction efficacy, while the bidirectional consistency constraint combined with the local anti-folding constraint ensures a more desirable topology-preserving registration mapping.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Myocardial T1 mapping at 5T using multi-inversion recovery real-time spoiled GRE

    physics.med-ph 2025-01 conditional novelty 6.0 of 10

    mIR-rt, a multi-inversion-recovery Look-Locker sequence with real-time GRE, enables myocardial T1 mapping at 5T and reports T1 around 1550 ms, showing MOLLI underestimates.

Pith tools