REVIEW 1 cited by
Full-scale Microwave SQUID Multiplexer Readout System for Magnetic Microcalorimeters
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Full-scale Microwave SQUID Multiplexer Readout System for Magnetic Microcalorimeters
read the original abstract
The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities. The readout of such arrays, however, presents a major challenge in terms of system complexity, parasitic heat load, and cost, which can be overcome only through multiplexing. Among the various multiplexing approaches, microwave SQUID multiplexing currently represents the state of the art, in particular for magnetic microcalorimeter (MMC) readout. In this work, we demonstrate the successful operation of the latest generation of our microwave SQUID multiplexer-based readout system, based on a SQUID multiplexer tailored for MMC readout and a custom full-scale software-defined radio (SDR) electronics, capable of handling up to 400 channels. The system operates reliably across the entire 4-8 GHz frequency band and achieves sufficiently low flux noise levels in flux-ramp-demodulated readout. Our results confirm that our system is fully functional and provides a scalable path towards future large-scale, high-resolution MMC experiments.
Forward citations
Cited by 1 Pith paper
-
Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection
Characterization of an aluminum μMUX prototype reports flux sensitivities of 1-1.5 μΦ₀/√Hz (open-loop) and 0.3-0.6 μΦ₀/√Hz (with JTWPA), validating the technology for TES readout in CEνNS detection.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.