Pith. sign in

REVIEW 4 cited by

CLIP Itself is a Strong Fine-tuner: Achieving 85.7% and 88.0% Top-1 Accuracy with ViT-B and ViT-L on ImageNet

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2212.06138 v1 pith:BJ2NLSZE submitted 2022-12-12 cs.CV cs.LG

classification cs.CVcs.LG
keywords clipfine-tuningperformanceaccuracyhyper-parameteritselftop-1achieve
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Recent studies have shown that CLIP has achieved remarkable success in performing zero-shot inference while its fine-tuning performance is not satisfactory. In this paper, we identify that fine-tuning performance is significantly impacted by hyper-parameter choices. We examine various key hyper-parameters and empirically evaluate their impact in fine-tuning CLIP for classification tasks through a comprehensive study. We find that the fine-tuning performance of CLIP is substantially underestimated. Equipped with hyper-parameter refinement, we demonstrate CLIP itself is better or at least competitive in fine-tuning compared with large-scale supervised pre-training approaches or latest works that use CLIP as prediction targets in Masked Image Modeling. Specifically, CLIP ViT-Base/16 and CLIP ViT-Large/14 can achieve 85.7%,88.0% finetuning Top-1 accuracy on the ImageNet-1K dataset . These observations challenge the conventional conclusion that CLIP is not suitable for fine-tuning, and motivate us to rethink recently proposed improvements based on CLIP. We will release our code publicly at \url{https://github.com/LightDXY/FT-CLIP}.

Discussion (0). Sign in to comment.

Forward citations

Cited by 4 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Prognostic Value of Lung Ultrasound Biomarkers for Readmission Risk in Congestive Heart Failure: A Pilot Data-Driven Analysis

    eess.SP 2026-05 unverdicted novelty 6.0 of 10

    Pilot study uses pretrained video encoder features from lung ultrasound to predict 30-day CHF readmission, finding lower-lung views and temporal differences most informative with top MLP F1 of 0.80.

  2. FoMo4Wheat: Toward reliable crop vision foundation models with globally curated data

    cs.CV 2025-09 conditional novelty 6.0 of 10

    Training a vision transformer on 2.5 million wheat images outperforms general-domain backbones across ten crop vision tasks.

  3. Mitigating Data Exfiltration Attacks through Layer-Wise Learning Rate Decay Fine-Tuning

    cs.LG 2025-08 conditional novelty 6.0 of 10

    A layer-wise learning rate decay fine-tuning protocol corrupts steganographically embedded training data in exported medical models while preserving classification utility.

  4. Sigmoid Loss for Language Image Pre-Training

    cs.CV 2023-03 conditional novelty 6.0 of 10

    SigLIP replaces softmax-based contrastive loss with a simple pairwise sigmoid loss for vision-language pre-training, decoupling batch size from normalization and reaching strong zero-shot performance with limited compute.

Pith tools