REVIEW 5 cited by
Calibrating High-Precision Faraday Rotation Measurements for LOFAR and the Next Generation of Low-Frequency Radio Telescopes
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Calibrating High-Precision Faraday Rotation Measurements for LOFAR and the Next Generation of Low-Frequency Radio Telescopes
read the original abstract
Faraday rotation measurements using the current and next generation of low-frequency radio telescopes will provide a powerful probe of astronomical magnetic fields. However, achieving the full potential of these measurements requires accurate removal of the time-variable ionospheric Faraday rotation contribution. We present ionFR, a code that calculates the amount of ionospheric Faraday rotation for a specific epoch, geographic location, and line-of-sight. ionFR uses a number of publicly available, GPS-derived total electron content maps and the most recent release of the International Geomagnetic Reference Field. We describe applications of this code for the calibration of radio polarimetric observations, and demonstrate the high accuracy of its modeled ionospheric Faraday rotations using LOFAR pulsar observations. These show that we can accurately determine some of the highest-precision pulsar rotation measures ever achieved. Precision rotation measures can be used to monitor rotation measure variations - either intrinsic or due to the changing line-of-sight through the interstellar medium. This calibration is particularly important for nearby sources, where the ionosphere can contribute a significant fraction of the observed rotation measure. We also discuss planned improvements to ionFR, as well as the importance of ionospheric Faraday rotation calibration for the emerging generation of low-frequency radio telescopes, such as the SKA and its pathfinders.
Forward citations
Cited by 5 Pith papers
-
Polarisation and Faraday rotation measure imaging at metre wavelengths with sub-arcsecond resolution: a foundational calibration strategy
A calibration strategy using full-Jones corrections with an in-field unpolarised calibrator and visibility-based multi-epoch alignment enables sub-arcsecond polarimetric imaging with LOFAR at metre wavelengths.
-
Relativistic effects of PSR~J1856--0039 double neutron star system in a 2.36-hour compact orbit
PSR J1856–0039 is a compact double neutron star with the lowest known total mass (2.4884 solar masses), and its orbital decay matches general relativity.
-
Studying Ionosphere Using SKA-Low and SKA-Mid
A multi-telescope comparative study of ionospheric phase fluctuations, TEC gradients, and scintillation is used to assess impacts on calibration and forecast effects for SKA-Low and SKA-Mid.
-
Exploring the Galactic plasma with pulsars in the SKA Era
Pulsars map Galactic, solar-wind, and ionospheric plasma via DM, RM, scintillation, and scattering; SKA-Low/Mid AA4 will push DM precision to ~10^{-8} pc cm^{-3} and transform IISM models.
-
Exploring the Galactic plasma with pulsars in the SKA Era
Pulsars map Galactic, heliospheric and ionospheric plasma; SKA will deliver order-of-magnitude gains in DM/RM precision and scattering characterisation.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.