Pith. sign in

REVIEW 1 cited by

Optimizing Calibration by Gaining Aware of Prediction Correctness

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.13016 v3 pith:MGL4MUEE submitted 2024-04-19 cs.CV cs.LGstat.ML

classification cs.CVcs.LGstat.ML
keywords calibrationconfidencelosscalibratorclasscorrectnessmodelpredicted
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Model calibration aims to align confidence with prediction correctness. The Cross-Entropy (CE) loss is widely used for calibrator training, which enforces the model to increase confidence on the ground truth class. However, we find the CE loss has intrinsic limitations. For example, for a narrow misclassification (e.g., a test sample is wrongly classified and its softmax score on the ground truth class is 0.4), a calibrator trained by the CE loss often produces high confidence on the wrongly predicted class, which is undesirable. In this paper, we propose a new post-hoc calibration objective derived from the aim of calibration. Intuitively, the proposed objective function asks that the calibrator decrease model confidence on wrongly predicted samples and increase confidence on correctly predicted samples. Because a sample itself has insufficient ability to indicate correctness, we use its transformed versions (e.g., rotated, greyscaled, and color-jittered) during calibrator training. Trained on an in-distribution validation set and tested with isolated, individual test samples, our method achieves competitive calibration performance on both in-distribution and out-of-distribution test sets compared with the state of the art. Further, our analysis points out the difference between our method and commonly used objectives such as CE loss and Mean Square Error (MSE) loss, where the latters sometimes deviates from the calibration aim.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Sample Margin-Aware Recalibration of Temperature Scaling

    cs.LG 2025-06 conditional novelty 6.0 of 10

    SMART learns a per-sample temperature from the gap between the top two logits using a soft-bin ECE objective, achieving strong calibration with as few as 50 validation samples.

Pith tools