Pith. sign in

REVIEW 1 cited by

Grounding Chest X-Ray Visual Question Answering with Generated Radiology Reports

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2505.16624 v1 pith:5ALB42SU submitted 2025-05-22 cs.CV cs.CL

Grounding Chest X-Ray Visual Question Answering with Generated Radiology Reports

classification cs.CV cs.CL
keywords questionsmodelradiologyreportsimage-differencesingle-imageperformancepredicted
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We present a novel approach to Chest X-ray (CXR) Visual Question Answering (VQA), addressing both single-image image-difference questions. Single-image questions focus on abnormalities within a specific CXR ("What abnormalities are seen in image X?"), while image-difference questions compare two longitudinal CXRs acquired at different time points ("What are the differences between image X and Y?"). We further explore how the integration of radiology reports can enhance the performance of VQA models. While previous approaches have demonstrated the utility of radiology reports during the pre-training phase, we extend this idea by showing that the reports can also be leveraged as additional input to improve the VQA model's predicted answers. First, we propose a unified method that handles both types of questions and auto-regressively generates the answers. For single-image questions, the model is provided with a single CXR. For image-difference questions, the model is provided with two CXRs from the same patient, captured at different time points, enabling the model to detect and describe temporal changes. Taking inspiration from 'Chain-of-Thought reasoning', we demonstrate that performance on the CXR VQA task can be improved by grounding the answer generator module with a radiology report predicted for the same CXR. In our approach, the VQA model is divided into two steps: i) Report Generation (RG) and ii) Answer Generation (AG). Our results demonstrate that incorporating predicted radiology reports as evidence to the AG model enhances performance on both single-image and image-difference questions, achieving state-of-the-art results on the Medical-Diff-VQA dataset.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. MEDIC-AD: Towards Medical Vision-Language Model's Clinical Intelligence

    cs.CV 2026-03 reject novelty 5.0

    MEDIC-AD adds anomaly-aware and difference tokens to a medical VLM, claiming SOTA lesion detection, temporal tracking, and visual grounding; the zero-shot claim is undermined by likely train/test overlap.