pith. sign in

arxiv: 2509.05204 · v2 · submitted 2025-09-05 · 🪐 quant-ph · cond-mat.mes-hall· physics.app-ph· physics.optics

Laser-enhanced quantum sensing boosts sensitivity and dynamic range

Pith reviewed 2026-05-18 19:00 UTC · model grok-4.3

classification 🪐 quant-ph cond-mat.mes-hallphysics.app-phphysics.optics
keywords nitrogen-vacancy centerslaser threshold magnetometryquantum sensingoptical contrastmagnetometer sensitivitydynamic rangevector magnetometry
0
0 comments X

The pith

Embedding NV centers in a laser cavity allows magnetic resonance to fully switch the laser off, achieving 100% optical contrast and sub-400 fT sensitivity.

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The paper shows that incorporating nitrogen-vacancy centers into a laser cavity makes their magnetic resonance shift the lasing threshold. This produces complete optical contrast, turning the laser output from full power to zero with the resonance signal. Strong signals up to 50 mW are maintained while reaching photon-shot-noise-limited sensitivities below 400 fT per square root hertz for all three magnetic field components. Sensitivity improves super-linearly as contrast rises, and the ratio of sensitivity to dynamic range improves by up to 590 times over typical fluorescence-based or vapor cell sensors. The result opens a path to high-performance vector magnetometers that could function without magnetic shielding.

Core claim

By integrating NV centers into a laser cavity and observing magnetic-field-dependent shifts of the laser threshold, the system achieves 100% optical contrast, allowing the laser to be entirely switched off by the NV magnetic resonance while delivering output powers up to 50 mW. This yields a photon-shot-noise-limited sensitivity of less than 400 fT/√Hz for all vector components, with sensitivity improving super-linearly with contrast, and an improvement factor of up to 590 in the sensitivity-dynamic range ratio compared to standard methods.

What carries the argument

Laser threshold magnetometry, in which the NV magnetic resonance controls the laser output by shifting the threshold for lasing.

Load-bearing premise

The observed laser threshold shifts result exclusively from the NV centers' magnetic resonance without interference from technical noise or cavity instabilities.

What would settle it

An experiment that applies a magnetic field to detune the NV resonance while monitoring if the laser threshold shift disappears, or a noise spectrum analysis confirming no excess noise beyond photon shot noise at the claimed sensitivity level.

read the original abstract

Magnetometers based on nitrogen-vacancy (NV) centers in diamond have emerged as the most important solid-state quantum sensors. However, ensembles are limited in optical contrast to typically a few percent and high-sensitivity variants usually possess only a few $\mathrm{\upmu}$T dynamic range. Here, we demonstrate a laser threshold magnetometry-based NV system that avoids these limitations. By integrating the NV centers into a laser cavity and showing magnetic-field-dependent shifts of the laser threshold, we observe 100\,\% optical contrast, i.\,e., we are able to entirely switch off the laser system with the NV centers magnetic resonance. At the same time we achieve strong output signals up to 50\,mW. The system exhibits a photon-shot-noise-limited (PSNL) sensitivity of $<$400\,fT/$\sqrt{\textrm{Hz}}$ for all vector components, which we demonstrate to improve super-linearly with contrast. The ratio of the sensing-relevant parameters PSNL sensitivity and dynamic range, that can be traded at the cost of each other, marks an improvement factor of up to 590 over typical fluorescence-based readout and vapor cell sensors while also adding vector magnetometry capabilities. Such performance improvements provide a perspective for a highly sensitive magnetometer, which could be operated outside a magnetically-shielded room. This could bring a new generation of sensors for applications including magnetoencephalography, magnetic navigation, and magnetic anomaly detection.

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, simulated authors' rebuttal, and a circularity audit. Tearing a paper down is the easy half of reading it; the pith above is the substance, this is the friction.

Referee Report

2 major / 2 minor

Summary. The manuscript presents an experimental demonstration of laser threshold magnetometry using nitrogen-vacancy (NV) centers in diamond integrated into a laser cavity. By showing magnetic-field-dependent shifts of the laser threshold, the authors report achieving 100% optical contrast (complete switch-off of the laser via NV magnetic resonance), output powers up to 50 mW, a photon-shot-noise-limited sensitivity below 400 fT/√Hz for all vector components that improves super-linearly with contrast, and an improvement factor of up to 590 in the sensitivity-dynamic range ratio compared to typical fluorescence-based readout and vapor cell sensors, with added vector magnetometry capabilities for potential use outside shielded rooms.

Significance. If the central experimental claims hold after verification, this work would represent a meaningful advance in solid-state quantum magnetometry by overcoming typical limitations in optical contrast (few percent) and dynamic range (few μT) for ensemble NV sensors. The integration of NV centers into a laser cavity to achieve full contrast and high-power output, combined with the reported super-linear sensitivity scaling, could enable practical high-sensitivity vector sensing in unshielded environments for applications such as magnetoencephalography, magnetic navigation, and anomaly detection.

major comments (2)
  1. [Abstract and laser threshold magnetometry demonstration] Abstract and the section on the laser threshold magnetometry demonstration: the central claims of 100% optical contrast and photon-shot-noise-limited (PSNL) sensitivity of <400 fT/√Hz rest on magnetic-field-dependent laser threshold shifts being produced exclusively by NV magnetic resonance (via absorption/fluorescence changes). No explicit control experiments, noise-budget measurements, or power spectral density data are described to rule out contributions from thermal lensing, pump-power fluctuations, cavity-length drifts, or other technical noise sources at the reported level; without these the PSNL assertion and the super-linear improvement with contrast cannot be verified.
  2. [Abstract and performance comparison] The reported improvement factor of up to 590 (ratio of PSNL sensitivity to dynamic range) compared to fluorescence-based and vapor cell sensors is a load-bearing quantitative claim for the paper's significance. The manuscript does not provide the specific parameter values, reference sensor data, or calculation details used to arrive at this factor, making it impossible to assess whether the comparison is on equal footing (e.g., same bandwidth, same vector capability).
minor comments (2)
  1. [Abstract] The abstract uses the abbreviation 'PSNL' without first spelling out 'photon-shot-noise-limited' on its initial appearance.
  2. [Abstract] Units are written as 'fT/√Hz' and 'μT'; consistent use of math mode or explicit square-root notation would improve readability.

Simulated Author's Rebuttal

2 responses · 0 unresolved

We thank the referee for their careful reading and constructive comments. We address each major point below and will revise the manuscript to incorporate additional details and data as needed.

read point-by-point responses
  1. Referee: [Abstract and laser threshold magnetometry demonstration] Abstract and the section on the laser threshold magnetometry demonstration: the central claims of 100% optical contrast and photon-shot-noise-limited (PSNL) sensitivity of <400 fT/√Hz rest on magnetic-field-dependent laser threshold shifts being produced exclusively by NV magnetic resonance (via absorption/fluorescence changes). No explicit control experiments, noise-budget measurements, or power spectral density data are described to rule out contributions from thermal lensing, pump-power fluctuations, cavity-length drifts, or other technical noise sources at the reported level; without these the PSNL assertion and the super-linear improvement with contrast cannot be verified.

    Authors: We agree that the current presentation would benefit from more explicit controls. The manuscript shows magnetic-field dependence tied to the NV resonance frequency and demonstrates sensitivity scaling that is consistent with photon-shot-noise limits, but dedicated off-resonance stability measurements and a full noise budget are not detailed in the main text. In the revised manuscript we will add a section presenting control data (laser output with NV resonance detuned), power spectral density traces, and a quantitative noise budget that rules out thermal lensing, pump fluctuations, and cavity drifts at the reported level. This will also make the super-linear contrast dependence more transparent. revision: yes

  2. Referee: [Abstract and performance comparison] The reported improvement factor of up to 590 (ratio of PSNL sensitivity to dynamic range) compared to fluorescence-based and vapor cell sensors is a load-bearing quantitative claim for the paper's significance. The manuscript does not provide the specific parameter values, reference sensor data, or calculation details used to arrive at this factor, making it impossible to assess whether the comparison is on equal footing (e.g., same bandwidth, same vector capability).

    Authors: The 590-fold improvement is obtained by dividing the sensitivity-dynamic-range product of the laser-threshold system by the corresponding products for representative fluorescence-based NV sensors and vapor-cell magnetometers drawn from the literature. To allow direct verification, the revised manuscript will include an explicit table listing the numerical values of sensitivity, dynamic range, bandwidth, and vector capability used for both our device and the reference sensors, together with the step-by-step calculation of the ratio. This will confirm that the comparison is performed on equivalent footing. revision: yes

Circularity Check

0 steps flagged

No circularity: experimental observations of threshold shifts and PSNL sensitivity stand on direct measurements

full rationale

The paper reports experimental integration of NV centers into a laser cavity, direct observation of magnetic-field-dependent laser threshold shifts yielding 100% optical contrast, and measured PSNL sensitivity below 400 fT/√Hz that improves super-linearly with contrast. No equations, fitted parameters renamed as predictions, or self-citation chains appear in the abstract or described results. Claims rest on empirical data rather than any derivation that reduces to its own inputs by construction. External controls for noise and alternative mechanisms are a separate correctness concern, not circularity.

Axiom & Free-Parameter Ledger

0 free parameters · 0 axioms · 0 invented entities

The work is an experimental demonstration that relies on established properties of NV centers and laser physics from prior literature; the abstract introduces no new free parameters, axioms, or invented entities.

pith-pipeline@v0.9.0 · 5836 in / 1283 out tokens · 47927 ms · 2026-05-18T19:00:41.301993+00:00 · methodology

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. A robust laser cavity platform for NV-diamond singlet infrared absorption magnetometry

    quant-ph 2026-04 unverdicted novelty 5.0

    A compact external cavity diode laser with NV-diamond achieves five-fold ODMR contrast enhancement near threshold and 7.6 nT/sqrt(Hz) sensitivity above threshold for singlet infrared absorption magnetometry.

Reference graph

Works this paper leans on

89 extracted references · 89 canonical work pages · cited by 1 Pith paper

  1. [1]

    Boto,et al., Moving magnetoencephalography towards real-world applications with a wear- able system.Nature555, 657–661 (2018)

    E. Boto,et al., Moving magnetoencephalography towards real-world applications with a wear- able system.Nature555, 657–661 (2018)

  2. [2]

    M. J. Brookes,et al., Magnetoencephalography with optically pumped magnetometers (OPM- MEG): the next generation of functional neuroimaging.Trends Neurosci.45(8), 621–634 (2022)

  3. [3]

    Aslam,et al., Quantum sensors for biomedical applications.Nat

    N. Aslam,et al., Quantum sensors for biomedical applications.Nat. Rev. Phys.5, 157–169 (2023)

  4. [4]

    M¨antynen, T

    V . M¨antynen, T. Konttila, M. Stenroos, Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model.Phys. Med. Biol.59(23), 7141 (2014)

  5. [5]

    Morales,et al., Magnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature.Phys

    S. Morales,et al., Magnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature.Phys. Med. Biol.62(18), 7267 (2017)

  6. [6]

    Greco,et al., Discrimination of finger movements by magnetomyography with optically pumped magnetometers.Sci

    A. Greco,et al., Discrimination of finger movements by magnetomyography with optically pumped magnetometers.Sci. Rep.13(22157) (2023)

  7. [7]

    Yun,et al., Magnetomyography: A novel modality for non-invasive muscle sensing (bioRxiv:2024.04.15.588623) (2024)

    R. Yun,et al., Magnetomyography: A novel modality for non-invasive muscle sensing (bioRxiv:2024.04.15.588623) (2024)

  8. [8]

    Mellinger,et al., An MEG-based brain–computer interface (BCI).NeuroImage36(3), 581– 593 (2007)

    J. Mellinger,et al., An MEG-based brain–computer interface (BCI).NeuroImage36(3), 581– 593 (2007)

  9. [9]

    Bu,et al., Magnetoencephalogram-based brain–computer interface for hand-gesture decod- ing using deep learning.Cereb

    Y . Bu,et al., Magnetoencephalogram-based brain–computer interface for hand-gesture decod- ing using deep learning.Cereb. Cortex33(14), 8942–8955 (2023)

  10. [10]

    Schmidt,et al., GETMAG – a SQUID Magnetic Tensor Gradiometer for Mineral and Oil Exploration.Explor

    P. Schmidt,et al., GETMAG – a SQUID Magnetic Tensor Gradiometer for Mineral and Oil Exploration.Explor . Geophys.35(4), 297–305 (2004)

  11. [11]

    Collar, P

    F. Collar, P. Fenning, C. Mora, Application of drillhole vector magnetic measurements to re- solve the position of existing underground structures.NDT & E Int.38(3), 231–236 (2005)

  12. [12]

    M. L. Psiaki, F. Martel, P. K. Pal, Three-Axis Attitude Determination via Kalman Filtering of Magnetometer Data.J. Guid. Control Dyn.13(3), 506–514 (2012)

  13. [13]

    J. D. Searcy, H. J. Pernicka, Magnetometer-Only Attitude Determination Using Novel Two- Step Kalman Filter Approach.J. Guid. Control Dyn.35(6) (2012)

  14. [14]

    M. H. Afzal, V . Renaudin, G. Lachapelle, Use of Earth’s Magnetic Field for Mitigating Gyro- scope Errors Regardless of Magnetic Perturbation.Sensors11(12), 11390–11414 (2011)

  15. [15]

    J. A. Shockley, J. F. Raquet, Navigation of Ground Vehicles Using Magnetic Field Variations. NA VIGATION61(4), 237–252 (2014). 14

  16. [16]

    Wang,et al., Quantum diamond magnetometry for navigation in GNSS denied environ- ments, inGravity, Positioning and Reference Frames

    X. Wang,et al., Quantum diamond magnetometry for navigation in GNSS denied environ- ments, inGravity, Positioning and Reference Frames. REF AG 2022. International Association of Geodesy Symposia(Springer, Cham, 2023), pp. 87–92

  17. [17]

    Hatano,et al., High-precision robust monitoring of charge/discharge current over a wide dynamic range for electric vehicle batteries using diamond quantum sensors.Sci

    Y . Hatano,et al., High-precision robust monitoring of charge/discharge current over a wide dynamic range for electric vehicle batteries using diamond quantum sensors.Sci. Rep.12, 13991 (2022)

  18. [18]

    Kajiyama,et al., Heteroepitaxial (111) Diamond Quantum Sensors with Preferentially Aligned Nitrogen-Vacancy Centers for an Electric Vehicle Battery Monitor.Adv

    K. Kajiyama,et al., Heteroepitaxial (111) Diamond Quantum Sensors with Preferentially Aligned Nitrogen-Vacancy Centers for an Electric Vehicle Battery Monitor.Adv. Quantum Technol.8(4), 2400400 (2025)

  19. [19]

    Schofield,et al., Quantum enabled functional neuroimaging: the why and how of magne- toencephalography using optically pumped magnetometers.Contemp

    H. Schofield,et al., Quantum enabled functional neuroimaging: the why and how of magne- toencephalography using optically pumped magnetometers.Contemp. Phys.63(3), 161–179 (2022)

  20. [20]

    K.-M. C. Fu, G. Z. Iwata, A. Wickenbrock, D. Budker, Sensitive magnetometry in challenging environments.A VS Quantum Sci.2(4), 044702 (2020)

  21. [21]

    Budker, M

    D. Budker, M. Romails, Optical Magnetometry.Nat. Phys.3, 227–234 (2007)

  22. [22]

    Elzenheimer,et al., Key Metrics and Experimental Test Bench for Assessing Highly Sensi- tive Magnetometers in Research.IEEE Sens

    E. Elzenheimer,et al., Key Metrics and Experimental Test Bench for Assessing Highly Sensi- tive Magnetometers in Research.IEEE Sens. J.25(2), 2432–2455 (2025)

  23. [23]

    Zhang,et al., Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement.Phys

    C. Zhang,et al., Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement.Phys. Rev. Appl.15, 064075 (2021)

  24. [24]

    Masuyama,et al., Gradiometer Using Separated Diamond Quantum Magnetometers.Sen- sors21(3), 977 (2021)

    Y . Masuyama,et al., Gradiometer Using Separated Diamond Quantum Magnetometers.Sen- sors21(3), 977 (2021)

  25. [25]

    Gizzi,et al., Nitrogen-vacancy centers for prosthesis control, inBiophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies and Wearables V(SPIE, 2024), pp

    L. Gizzi,et al., Nitrogen-vacancy centers for prosthesis control, inBiophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies and Wearables V(SPIE, 2024), pp. 92–101

  26. [26]

    M. W. Doherty,et al., The nitrogen-vacancy colour centre in diamond.Phys. Rep.528(1), 1–45 (2013)

  27. [27]

    E. V . Levine,et al., Principles and techniques of the quantum diamond microscope.Nanopho- tonics8(11), 1945–1973 (2012)

  28. [28]

    Rondin,et al., Magnetometry with nitrogen-vacancy defects in diamond.Rep

    L. Rondin,et al., Magnetometry with nitrogen-vacancy defects in diamond.Rep. Prog. Phys. 77(5), 056503 (2014)

  29. [29]

    J. M. Schloss, J. F. Barry, M. J. Turner, R. L. Walsworth, Simultaneous Broadband Vector Magnetometry Using Solid-State Spins.Phys. Rev. Appl.10, 034044 (2018)

  30. [30]

    Stepanov, F

    V . Stepanov, F. H. Cho, C. Abeywardana, S. Takahashi, High-frequency and high-field opti- cally detected magnetic resonance of nitrogen-vacancy center in diamond.Appl. Phys. Lett. 106(6), 063111 (2015). 15

  31. [31]

    J. F. Barry,et al., Sensitive AC and DC Magnetometry with Nitrogen-Vacancy Center Ensem- bles in Diamond.Phys. Rev. Appl.22, 044069 (2024)

  32. [32]

    S. M. Graham,et al., Fiber-coupled Diamond Magnetometry with an Unshielded Sensitivity of 30 pT/ √ Hz.Phys. Rev. Appl.19, 044042 (2023)

  33. [33]

    Sekiguchi,et al., Diamond quantum magnetometer with dc sensitivity of sub-10 pT/ √ Hz toward measurement of biomagnetic field.Phys

    N. Sekiguchi,et al., Diamond quantum magnetometer with dc sensitivity of sub-10 pT/ √ Hz toward measurement of biomagnetic field.Phys. Rev. Appl.21, 064010 (2024)

  34. [34]

    Zhang,et al., Blueprint for Diamond Magnetometry: Unraveling Quantum Dephasing of Nitrogen-Vacancy Center Ensembles in Diamond (arXiv:2408.14318) (2025)

    J. Zhang,et al., Blueprint for Diamond Magnetometry: Unraveling Quantum Dephasing of Nitrogen-Vacancy Center Ensembles in Diamond (arXiv:2408.14318) (2025)

  35. [35]

    E. R. Eisenach,et al., Cavity-enhanced microwave readout of a solid-state spin sensor.Nat. Commun.12, 1357 (2021)

  36. [36]

    Wang,et al., A spin-refrigerated cavity quantum electrodynmic sensor.Nat

    H. Wang,et al., A spin-refrigerated cavity quantum electrodynmic sensor.Nat. Commun.15, 10320 (2024)

  37. [37]

    Fescenko,et al., Diamond magnetometer enhanced by ferrite flux concentrators.Phys

    I. Fescenko,et al., Diamond magnetometer enhanced by ferrite flux concentrators.Phys. Rev. Res.2, 023394 (2020)

  38. [38]

    Xie,et al., A hybrid magnetometer towards femtotesla sensitivity under ambient conditions

    Y . Xie,et al., A hybrid magnetometer towards femtotesla sensitivity under ambient conditions. Sci. Bull.66(2), 127–132 (2021)

  39. [39]

    Gao,et al., High sensitivity of diamond nitrogen-vacancy magnetometer with magnetic flux concentrators via enhanced fluorescence collection.Diamond Relat

    X. Gao,et al., High sensitivity of diamond nitrogen-vacancy magnetometer with magnetic flux concentrators via enhanced fluorescence collection.Diamond Relat. Mater .139, 110348 (2023)

  40. [40]

    Shao,et al., High-sensitivity optical-fiber magnetic sensor based on diamond and magnetic flux concentrators.Opt

    J. Shao,et al., High-sensitivity optical-fiber magnetic sensor based on diamond and magnetic flux concentrators.Opt. Express31(9), 14685–14693 (2023)

  41. [41]

    M. S. Ziabari,et al., Earth’s field diamond vector magnetometry with isotropic magnetic flux concentrators (arXiv:2507.00215) (2025)

  42. [42]

    J. F. Barry,et al., Sensitivity Optimization for NV-Diamond Magnetometry.Rev. Mod. Phys. 92(2020)

  43. [43]

    Jeske, J

    J. Jeske, J. H. Cole, A. D. Greentree, Laser threshold magnetometry.New J. Phys.18, 013015 (2015)

  44. [44]

    Dumeige,et al., Infrared laser threshold magnetometry with a NV doped diamond intracav- ity etalon.Opt

    Y . Dumeige,et al., Infrared laser threshold magnetometry with a NV doped diamond intracav- ity etalon.Opt. Express27(2), 1706–1717 (2019)

  45. [45]

    S. R. Nair,et al., Absorptive laser threshold magnetometry: combining visible diamond Raman lasers and nitrogen-vacancy centres.Mater . Quantum Technol.1(2), 025003 (2021)

  46. [46]

    J. L. Webb,et al., Laser threshold magnetometry using green-light absorption by diamond nitrogen vacancies in an external cavity laser.Phys. Rev. A103, 062603 (2021). 16

  47. [47]

    Jeske,et al., Stimulated emission from nitrogen-vacancy centres in diamond.Nat

    J. Jeske,et al., Stimulated emission from nitrogen-vacancy centres in diamond.Nat. Commun. 8, 14000 (2017)

  48. [48]

    S. R. Nair,et al., Amplification by stimulated emission of nitrogen-vacancy centres in a diamond-loaded fibre cavity.Nanophotonics9(15), 4505–4518 (2020)

  49. [49]

    Savvin,et al., NV − diamond laser.Nat

    A. Savvin,et al., NV − diamond laser.Nat. Commun.12, 7118 (2021)

  50. [50]

    Lindner,et al., Dual-media laser system: Nitrogen vacancy diamond and red semiconductor laser.Sci

    L. Lindner,et al., Dual-media laser system: Nitrogen vacancy diamond and red semiconductor laser.Sci. Adv.10(39), eadj3933 (2024)

  51. [51]

    Luo,et al., Creation of nitrogen-vacancy centers in chemical vapor deposition diamond for sensing applications.New J

    T. Luo,et al., Creation of nitrogen-vacancy centers in chemical vapor deposition diamond for sensing applications.New J. Phys.24, 033030 (2022)

  52. [52]

    V . P. Mironov,et al., Peculiarities of nitrogen-vacancy centers’ superluminescence in diamond under optical pumping at 532 nm.Appl. Phys. B129(18) (2023)

  53. [53]

    Fraczek,et al., Laser spectroscopy of NV- and NV0 colour centres in synthetic diamond

    E. Fraczek,et al., Laser spectroscopy of NV- and NV0 colour centres in synthetic diamond. Opt. Mater . Express7(7), 2571–2585 (2017)

  54. [54]

    Capelli,et al., Increased nitrogen-vacancy centre creation yield in diamond through elec- tron beam irradiation at high temperature.Carbon143, 714–719 (2019)

    M. Capelli,et al., Increased nitrogen-vacancy centre creation yield in diamond through elec- tron beam irradiation at high temperature.Carbon143, 714–719 (2019)

  55. [55]

    Luo,et al., Absorption and birefringence study for reduced optical losses in diamond with high nitrogen-vacancy concentration.Phil

    T. Luo,et al., Absorption and birefringence study for reduced optical losses in diamond with high nitrogen-vacancy concentration.Phil. Trans. R. Soc. A.382(2265), 20220314 (2024)

  56. [56]

    F. A. Hahl,et al., Magnetic-field-dependant stimulated emission from nitrogen-vacancy cen- ters in diamond.Sci. Adv.8(22), eabn7192 (2022)

  57. [57]

    N. S. Gottesman,et al., Infrared vertical external cavity surface emitting laser threshold mag- netometer.Appl. Phys. Lett.124, 091110 (2024)

  58. [58]

    Rottstaedt,et al., Two-media laser threshold magnetometry: A magnetic-field-dependent laser threshold.APL Photonics10, 086112 (2025)

    Y . Rottstaedt,et al., Two-media laser threshold magnetometry: A magnetic-field-dependent laser threshold.APL Photonics10, 086112 (2025)

  59. [59]

    Jensen,et al., Cavity-Enhanced Room-Temperature Magnetometry Using Absorption by Nitrogen-Vacancy Centers in Diamond.Phys

    K. Jensen,et al., Cavity-Enhanced Room-Temperature Magnetometry Using Absorption by Nitrogen-Vacancy Centers in Diamond.Phys. Rev. Lett.112, 160802 (2014)

  60. [60]

    Chatzidrosos,et al., Miniature Cavity-Enhanced Diamond Magnetometer.Phys

    G. Chatzidrosos,et al., Miniature Cavity-Enhanced Diamond Magnetometer.Phys. Rev. Appl. 8, 044019 (2017)

  61. [61]

    Schall,et al., High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles.Opt

    F. Schall,et al., High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles.Opt. Express33(5), 10899–10910 (2025)

  62. [62]

    Tayefeh Younesi, R

    A. Tayefeh Younesi, R. Ulbricht, Broadband transient absorption spectroscopy using an inco- herent white-light source as probe.Opt. Express30(21), 38896–38906 (2022)

  63. [63]

    Kehayias,et al., Infrared absorption band and vibronic structure of the nitrogen-vacancy center in diamond.Phys

    P. Kehayias,et al., Infrared absorption band and vibronic structure of the nitrogen-vacancy center in diamond.Phys. Rev. B88, 165202 (2013). 17

  64. [64]

    Jetter, P

    M. Jetter, P. Michler, eds.,V ertical External Cavity Surface Emitting Lasers(WILEY-VCH, 2022)

  65. [65]

    V . M. Acosta,et al., Broadband magnetometry by infrared-absorption detection of nitrogen- vacancy ensembles in diamond.Appl. Phys. Lett.97, 174104 (2010)

  66. [66]

    V . M. Acosta, A. Jarmola, E. Bauch, D. Budker, Optical properties of the nitrogen-vacancy singlet levels in diamond.Phys. Rev. B82, 201202(R) (2010)

  67. [67]

    Dumeige,et al., Magnetometry with nitrogen-vacancy ensembles in diamond based on infrared absorption in a doubly resonant optical cavity.Phys

    Y . Dumeige,et al., Magnetometry with nitrogen-vacancy ensembles in diamond based on infrared absorption in a doubly resonant optical cavity.Phys. Rev. B87, 155202 (2013)

  68. [68]

    Tayefeh Younesi, M

    A. Tayefeh Younesi, M. Omar, A. Wickenbrock, D. Budker, R. Ulbricht, Towards high- sensitivity magnetometry with nitrogen-vacancy centers in diamond using the singlet infrared absorption.Phys. Rev. Appl.23, 054019 (2025)

  69. [69]

    T. P. M. Alegre, C. Santori, G. Medeiros-Ribeiro, R. G. Beausoleil, Polarization-selective ex- citation of nitrogen vacancy centers in diamond.Phys. Rev. B76, 165205 (2007)

  70. [70]

    M ¨unzhuber,et al., Polarization-Assisted Vector Magnetometry with No Bias Field Using an Ensemble of Nitrogen-Vacancy Centers in Diamond.Phys

    F. M ¨unzhuber,et al., Polarization-Assisted Vector Magnetometry with No Bias Field Using an Ensemble of Nitrogen-Vacancy Centers in Diamond.Phys. Rev. Appl.14, 014055 (2020)

  71. [71]

    Dr ´eau,et al., Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced dc magnetic field sensitivity.Phys

    A. Dr ´eau,et al., Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced dc magnetic field sensitivity.Phys. Rev. B84, 195204 (2011)

  72. [72]

    Ruan,et al., Magnetically sensitive nanodiamond-doped tellurite glass fibers.Sci

    Y . Ruan,et al., Magnetically sensitive nanodiamond-doped tellurite glass fibers.Sci. Rep.8, 1268 (2018)

  73. [73]

    Clevenson,et al., Robust high-dynamic-range vector magnetometry with nitrogen-vacancy centers in diamond.Appl

    H. Clevenson,et al., Robust high-dynamic-range vector magnetometry with nitrogen-vacancy centers in diamond.Appl. Phys. Lett.112(25), 252406 (2018)

  74. [74]

    Wang,et al., Realization of high-dynamic-range broadband magnetic-field sensing with ensemble nitrogen-vacancy centers in diamond.Rev

    C. Wang,et al., Realization of high-dynamic-range broadband magnetic-field sensing with ensemble nitrogen-vacancy centers in diamond.Rev. Sci. Instrum.94(1), 015109 (2023)

  75. [75]

    Dai,et al., A Fully-Integrated Diamond Nitrogen-Vacancy Magnetometer with Nanotesla Sensitivity.Adv

    Y . Dai,et al., A Fully-Integrated Diamond Nitrogen-Vacancy Magnetometer with Nanotesla Sensitivity.Adv. Quantum Technol.8(4), 2300438 (2024)

  76. [76]

    Zheng,et al., Zero-Field Magnetometry Based on Nitrogen-Vacancy Ensembles in Dia- mond.Phys

    H. Zheng,et al., Zero-Field Magnetometry Based on Nitrogen-Vacancy Ensembles in Dia- mond.Phys. Rev. Appl.11, 064068 (2019)

  77. [77]

    F. M. St ¨urner,et al., Integrated and Portable Magnetometer Based on Nitrogen-Vacancy En- sembles in Diamond.Adv. Quantum Technol.4(4), 2000111 (2021)

  78. [78]

    Patel,et al., Subnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor.Phys

    R. Patel,et al., Subnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor.Phys. Rev. Appl.14, 044058 (2020)

  79. [79]

    Kainuma,et al., Compact and Stable Diamond Quantum Sensors for Wide Applications

    Y . Kainuma,et al., Compact and Stable Diamond Quantum Sensors for Wide Applications. Adv. Quantum Technol.7(9), 2300456 (2024). 18

  80. [80]

    QuSpin Inc., QTFM Gen-2, Louisville, Kentucky, available at: https://quspin.com/qtfm-gen- 2/, (accessed 1 September 2025)