Pith. sign in

REVIEW 5 cited by

Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv gr-qc/0008026 v2 pith:32R7WOTI submitted 2000-08-11 gr-qc quant-ph

Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics

classification gr-qc quant-ph
keywords interferometerinterferometersoutputlightdesignsdetectionhomodyneinput
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The LIGO-II gravitational-wave interferometers (ca. 2006--2008) are designed to have sensitivities at about the standard quantum limit (SQL) near 100 Hz. This paper describes and analyzes possible designs for subsequent, LIGO-III interferometers that can beat the SQL. These designs are identical to a conventional broad-band interferometer (without signal recycling), except for new input and/or output optics. Three designs are analyzed: (i) a "squeezed-input interferometer" (conceived by Unruh based on earlier work of Caves) in which squeezed vacuum with frequency-dependent (FD) squeeze angle is injected into the interferometer's dark port; (ii) a "variational-output" interferometer (conceived in a different form by Vyatchanin, Matsko and Zubova), in which homodyne detection with FD homodyne phase is performed on the output light; and (iii) a "squeezed-variational interferometer" with squeezed input and FD-homodyne output. It is shown that the FD squeezed-input light can be produced by sending ordinary squeezed light through two successive Fabry-Perot filter cavities before injection into the interferometer, and FD-homodyne detection can be achieved by sending the output light through two filter cavities before ordinary homodyne detection. With anticipated technology and with laser powers comparable to that planned for LIGO-II, these interferometers can beat the amplitude SQL by factors in the range from 3 to 5, corresponding to event rate increases between ~30 and ~100 over the rate for a SQL-limited interferometer.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 5 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Assessing the Impact of Instrumental Requirements on the Scientific Performance of the Einstein Telescope

    astro-ph.IM 2026-07 accept novelty 6.0

    Degrading the Einstein Telescope's sensitivity in specific frequency bands hurts different science goals in predictable ways, but the mission remains scientifically strong even in the worst modelled cases.

  2. Optomechanical transfer factors for scattered light noise estimations in the beamtubes of ground-based gravitational wave detectors

    gr-qc 2026-07 conditional novelty 6.0

    Scattered-light noise coupling to strain readout is derived as full optomechanical transfer factors, recovering legacy models only in phase-dominated regimes and substantially revising Einstein Telescope low-frequency...

  3. Probing Majoron Dark Matter with Gravitational Wave Detectors

    hep-ph 2026-04 unverdicted novelty 5.5

    Majoron dark matter coupled to photons via a QED anomaly induces oscillatory birefringence that Advanced LIGO, KAGRA, and future interferometers can probe with added optics.

  4. Probing Majoron Dark Matter with Gravitational Wave Detectors

    hep-ph 2026-04 unverdicted novelty 4.0

    Majoron dark matter with photon coupling fixed by electroweak and neutrino mass scales induces birefringence signals detectable by Advanced LIGO, KAGRA, and future ground-based laser interferometers.

  5. True and apparent motion of optomechanical resonators, with applications to feedback cooling of gravitational wave detector test masses

    quant-ph 2024-08 unverdicted novelty 4.0

    Extends prior two-photon formalism to compute true motion and optimal cooling in multi-DOF GW detector test masses, finding sub-unity occupation numbers possible over the oscillator bandwidth for common definitions.