Fluid Dynamics · arXiv:2508.04091 v3 · submitted 6 Aug 2025

Simulating The Urban Canopy's Impact on Wind-Driven Natural Ventilation

Nicholas Bachand, Hesam Salehipour, Catherine Gorle

The paper says

“The results demonstrate that the canopy's effect on ventilation rates is much more complex than those suggested by existing natural ventilation parameterizations.”

from the abstract · picked out as the main claim by a classifier

Pith says

Pith has not reviewed this paper.

Get a Pith Review, $5

Reviews

Reviews by people

No person has reviewed this paper on Pith yet. A scientist listed on Pith can review it for a fee, and their review is published here whatever it concludes.

Request a human review

How Pith checks papers · The full audit of this paper

The paper

Abstract

The urban canopy affects wind in complex ways, making it challenging to predict wind-driven natural ventilation and cooling in buildings. Using large eddy simulations of coupled outdoor and indoor airflow, we study how the surrounding urban canopy and wind angle influence ventilation rates through four ventilation configurations: cross, corner, dual-room, and single-sided. Flow visualizations demonstrate how both large-scale flow patterns and local interference effects can influence ventilation rates by 50-85%. In general, lower density canopies give higher ventilation rates and wind angles that align with a direct path between two openings also lead to higher ventilation rates. However, interference effects from surrounding buildings can significantly change the local wind speed and direction, thus also changing ventilation rates. The magnitude of these interference effects depends on both the wind angle and surrounding building geometries. The effect of wind angle is less pronounced in a higher density canopy, where the urban canopy geometry more strongly guides the flow. The results demonstrate that the canopy's effect on ventilation rates is much more complex than those suggested by existing natural ventilation parameterizations.

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. No sentence in this record was written by a model.

abstract compiled · 2026-11-13 · no language-model review

How the main claim is stated: asserted 1.00

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.18 · human participants 0.02 · controlled comparison 0.11 · randomized assignment 0.01 · states quantitative result 0.98 · compares with prior results 0.66 · mentions code or data availability 0.02

The abstract, sentence by sentence

This table labels the abstract only (arXiv listing abstract v3). The number is the probability the classifier gave the label.

SentenceRoleThe authors' own workStates the main conclusionStrength
The urban canopy affects wind in complex ways, making it challenging to predict wind-driven natural ventilation and cooling in buildings. background 0.99 0.06 0.06 asserted 1.00
Using large eddy simulations of coupled outdoor and indoor airflow, we study how the surrounding urban canopy and wind angle influence ventilation rates through four ventilation configurations: cross, corner, dual-room, and single-sided. method 0.52 0.97 0.05 asserted 0.90
Flow visualizations demonstrate how both large-scale flow patterns and local interference effects can influence ventilation rates by 50-85%. result 0.99 0.95 0.16 asserted 1.00
In general, lower density canopies give higher ventilation rates and wind angles that align with a direct path between two openings also lead to higher ventilation rates. result 0.99 0.92 0.24 asserted 0.97
However, interference effects from surrounding buildings can significantly change the local wind speed and direction, thus also changing ventilation rates. result 0.82 0.76 0.10 asserted 0.96
The magnitude of these interference effects depends on both the wind angle and surrounding building geometries. result 0.83 0.81 0.07 asserted 1.00
The effect of wind angle is less pronounced in a higher density canopy, where the urban canopy geometry more strongly guides the flow. result 0.93 0.90 0.09 asserted 1.00
The results demonstrate that the canopy's effect on ventilation rates is much more complex than those suggested by existing natural ventilation parameterizations. interpretation 0.94 0.87 0.78 asserted 1.00

What kind of paper the classifier reports this is: simulation study 1.00 · evidence from simulation or computation 1.00

What was examined, and what was not

Sources read

  • arXiv listing abstract v3

Not examined

  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers

Levels run

  • P abstract

Not run

  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

How the labels were made

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-11-13: 1 request, 6,177 input tokens.

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. This record as JSON

Cited by 1 Pith paper

Challenges and discussion

Know something about this paper? Leave a comment.

No comments yet.

Sign in to comment