Computation and Language · arXiv:2611.10601 v1 · submitted 7 Nov 2026 · 22 references
AI in the Clinical Documentation Loop: Effects of LLM-Induced Note Bloat and Diagnostic Overcall on Downstream LLMs
The paper says
“Large language models (LLMs) are increasingly used to process medical records for healthcare tasks such as clinical documentation. Because these tools also generate documentation, the relationship is now bidirectional: models both read from and write to the record.”
more of the abstract
Understanding how LLMs behave when reading records that already contain LLM-authored content is therefore critical for their safe deployment. In this study, we examine how LLM-authored content in the medical record affects downstream LLMs that read the same record. We consider two types of LLM-induced artifacts: bloat, in which LLM-generated summaries accumulate in the record and change the length and provenance of its content over time; and distortion, in which LLMs subtly alter clinical findings rather than fabricating facts outright. As a case of distortion, we study diagnostic overcall (documenting an unconfirmed differential diagnosis in the record) and test whether it propagates to the reader LLM's output. Across seven reader models from four families, we find evidence of both effects. First, LLM-generated summary notes modestly but consistently degraded downstream hospital-course generation compared with copy-forward and templated text of matched length. Second, injected overcalls reappeared in downstream outputs at rates that varied by reader model, without detectable changes in standard quality metrics. These findings show the need to monitor AI-generated content in medical records and to account for it when those records are later processed by AI.
from the abstract
Pith says
Machine review · deepseek-v4-flash · 10 Nov 2026 · what was read was not recorded · not checked by a person
It can be wrong. Challenge this review or reply to it.
Holds up. Solid, honest study showing that AI-generated clinical notes can silently degrade downstream LLM summaries and propagate unconfirmed diagnoses, with effect sizes that are modest but consistent. This line is wrong
2 major objections · 8 minor
How often objections from reviews like this one are right: not yet measured
Not checked: figures, code, what the 22 references say.
The paper says, at Table 1 & Appendix F
The review did not quote this passage.
A classifier read this sentence of the paper as acknowledging the concern (probability 0.69):
“This may explain why the clinician review (Appendix F) judged 10 of 24 injections not to be genuine overcalls.”
Pith says: Objection 1 of 2 · major
The clinician review (Appendix F) found that only 14 of 24 injections (58%) were genuine overcalls; the remaining 10 were reasonable given the record. The overall propagation rates reported in Table 1 (e.g., 24.6% for related targets) average over all injections, including non-genuine ones.
more of objection 1
While the authors note that genuine overcalls still propagated (7/14), the sample is small and the propagation rate for non-genuine injections is not separately reported. Since the central claim concerns the propagation of genuine AI-generated overcalls, the paper should report or estimate the propagation rate restricted to the subset of injections judged to be genuine overcalls, or discuss how the inclusion of non-genuine overcalls might affect the external validity of the measured rates. The authors already acknowledge the limitation (sentence b110, b192), but the reported primary estimates in Table 1 conflate two categories of injections.
The paper says, at §4.1 & Figure 2
The review did not quote this passage.
Pith says: Objection 2 of 2 · major
The bloat effect, while consistent, is modest—'about half the run-to-run variation of a single summary' (sentence b85 context). The clinical significance of a 0.47-point drop in judge-rated accuracy (1–5 scale) and a 3–4 pp drop in supported-claim share at dose 0.5 is not fully discussed.
more of objection 2
The paper would benefit from a brief qualitative assessment: at what dose does the degradation become clinically noticeable? Do the supported-claim losses systematically affect any particular type of claim (e.g., medications vs. findings)? The conclusion asserts that these effects 'should draw greater attention to the reliability of AI-based documentation tools,' but the modest effect sizes should be weighed against the practical costs of note bloat in real EHRs. This is a framing issue, not a flaw, but addressing it would strengthen the paper.
8 minor objections
The paper says, at Abstract & §1
Pith says: minor objection 1 of 8
The abstract mentions 'seven reader models from four families' but does not name them; consider adding a brief parenthetical list for clarity.
The paper says, at §3.2
Pith says: minor objection 2 of 8
The notation 'x_a,d_i' is introduced but the subscript ordering (a for setting, d for dose, i for admission) is not explicitly stated until later; define the subscripts at first use.
show 6 more
The paper says, at Figure 2 caption
Pith says: minor objection 3 of 8
The caption says 'Shades are 95% bootstrap CIs.' The figure uses semi-transparent bands; this is clear, but consider adding a note that the CIs are percentile bootstrap intervals from 2,000 resamples (as stated in §3.3).
The paper says, at Table 1
Pith says: minor objection 4 of 8
The Bonferroni adjustment is applied over the three main-reader rows. Clarify in the table title whether the intervals are adjusted for the three rows or for all comparisons in the table. Also, the row 'Five other readers 5.8–31.2 2.5–23.9' shows ranges; consider adding a footnote explaining these are the minima and maxima of the reader-specific rates (from Appendix Table 3).
The paper says, at Appendix B.1
Pith says: minor objection 5 of 8
The rephrased control (R-red) is applied only at doses 0.10, 0.25, and 0.50 (stated in §3.2 and Appendix B.1). In Table 5, the same three doses are reported. The main bloat results in Figure 2 include doses 0.05, 0.15, 0.20, 0.33 as well; the rephrased control is not tested at these doses. A brief justification for the restricted dose set would be helpful, even if it is due to computational cost.
The paper says, at §4.1, sentence b87
Pith says: minor objection 6 of 8
The sentence states 'AI-red still lowered ROUGE-L by 0.28, 0.59 and 0.92 pp against R-red (Appendix Table 5).' This is correct, but the phrasing 'still lowered' might imply a competition between effects; consider rephrasing to clearly separate the two contrasts (R-red vs. H-red isolates wording; AI-red vs. R-red isolates content). The text already does this, but a small rewording could avoid potential confusion.
The paper says, at Appendix G.2
Pith says: minor objection 7 of 8
The 'Diagnostic-overcall edit' prompt instructs the model to 'change nothing else' and 'output the rewritten passage only.' This is appropriate, but the prompt does not explicitly constrain the model to keep the same passage length or structure; in practice, Nemotron-generated edits were much shorter (median 5–6 added words vs. Qwen's 16). This length difference is noted in Appendix E.1 and is not a flaw, but the prompt design may partially explain it. Consider adding a brief note in Appendix B.2.
The paper says, at General
Pith says: minor objection 8 of 8
There are a few missing spaces or punctuation inconsistencies (e.g., 'Bloat' and 'Distortion' in the abstract are bolded with colons but not consistently; 'BHC generation' in Figure 1 has a line break). A thorough copy-edit would improve readability.
What would settle it
Reproduce the overcall propagation analysis on the subset of 14 clinician-confirmed genuine overcalls (Appendix F), reporting the propagation rate and 95% CI for this subgroup alone. If the rate remains significantly above zero and comparable to the full-sample estimate, the concern about synthetic construction is fully addressed.
from the skeptic's reading
How the review went
4 readings by deepseek-v4-flash · 10 Nov 2026
- Reader holds up
- Skeptic agrees
- Editor wrote the verdict above
- Referee minor revision: 2 major objections, 8 minor
Not run on this paper: the simulated authors' defence.
Pith did not check this review's objections against the paper.
The review in full
The review in brief, machine-written
This paper does something straightforward that nobody has done before: it takes a real EHR corpus, injects AI-written notes or diagnostic overcalls in controlled amounts, and measures what happens when a second LLM reads the altered record. The answer is that small but reliable degradations occur, and that overcalls—hedged, unconfirmed differentials—get carried forward into summaries at rates up to 24% without tripping standard metrics. The study design is the strong point: paired admissions, multiple doses, a rephrasing control that isolates content from authorship, seven reader models, two generators, and a blinded clinician review. The rephrased control cleanly shows that the bloat effect comes from what the AI summary says, not from its wording being AI-like. The clinician validation on a subset of overcall pairs is rare in this area and adds credibility. The authors are transparent about their limitations—synthetic data, ICD-9-based targets that 10 of 24 times were not genuine overcalls, modest cohort size. The overcall construction is the softest spot: many injections read verbatim from a condition list, which a clinician would not write. But the propagation pattern held even for the genuine overcalls (7 of 14 propagated, 5 of those with potential clinical impact), so the central finding survives its own stress test. The effect sizes are modest—a few tenths of a ROUGE-L point, a fraction of a point on a 1–5 accuracy scale—but consistent across models. That consistency is the story, not the size. This is a conference-paper-level contribution. It is clearly scoped, methodologically careful, and appropriately cautious in its conclusions. For a reader in NLP for healthcare or AI safety evaluation, this is worth a serious refereeing. I would say yes to peer review and expect a solid publication after minor tightening of the overcall narrative.
The strongest objection
The paper's central claim—that LLM-generated content in medical records can affect downstream LLMs—is supported by two independent lines of evidence (note bloat and diagnostic overcall). The strongest potential concern is the ecological validity of the synthetic diagnostic overcall construction (ICD-9-based injects, many judged not genuine by clinician review, §B.2, Appendix F). However, the authors transparently acknowledge this limitation (§5, §B.2, Appendix F) and partially mitigate it with a blinded clinician review that confirms the propagation pattern holds even for the subset of genuine overcalls (7/14 propagated, 5/7 with potential clinical impact). The bloat experiments are robust across doses, reader models, and generators, with a rephrased control isolating content from authorship. No critical flaw or internal inconsistency was identified that would weaken the core findings beyond what the authors themselves report.
The reader's weakest_assumption correctly identifies the synthetic overcall construction as the most fragile part of the argument. However, the authors' own clinician review provides evidence that the effect survives even when restricting to genuine overcalls, and the paper is explicit about its limitations. The bloat experiments are clean and well-controlled. I find no unaddressed concern that would justify adjusting the ACCEPT verdict. The paper makes a solid, honest contribution.
The referee's report
If the results hold, this work has immediate practical implications for the deployment of LLM-based clinical documentation tools, which are already in use at scale. The finding that AI-generated summary notes degrade downstream summarization, even modestly, and that unsupported differentials can propagate without detection by standard quality metrics, raises patient-safety concerns. The experimental design is strong: paired admissions, multiple doses, authorship controls (rephrasing), seven reader models from four families, two generators, and human validation of the overcall evaluator. The rephrased control convincingly separates content from authorship. The paper ships all prompts for reproducibility. The main limitations are the synthetic nature of the AI content (MIMIC-III predates AI documentation) and the ICD-code-based overcall construction, which the authors transparently acknowledge and partially mitigate with clinician review.
Pith's reading of the paper (a machine's summary, not the authors')
This paper shows that when medical records contain AI-generated notes, downstream LLMs that later read those records produce different summaries than they would from human-written notes of the same length and content. The authors study two types of AI-induced artifacts: 'note bloat' (accumulating AI-generated summary notes) and 'diagnostic overcall' (inserting hedged, unconfirmed differential diagnoses). In controlled experiments on 300 MIMIC-III admissions, they find that AI-written summary notes consistently degrade downstream hospital-course summarization compared to matched human-written or boilerplate notes. Injected diagnostic overcalls propagate into downstream summaries at rates between 2.5% and 31.2% depending on the reader model, without being detected by standard quality metrics like ROUGE-L or BERTScore. The paper argues that the bidirectional nature of LLMs both reading and writing to the record creates a feedback loop that requires monitoring.
What carries the argument. The controlled paired-perturbation experimental design is the central machinery. For bloat, the same record is augmented with AI-written summary notes (AI-red) or with human-written text of matched length and position (H-red and F-red), and the downstream summary from each version is compared to the original-record summary. For distortion, a selected passage is neutrally rephrased (control) or additionally edited to include a hedged differential diagnosis (overcall), and the two downstream summaries are compared. The key comparison is within-admission, paired, isolating the artifact's effect. The LLM-as-judge evaluator and clinician review provide validation for overcall propagation.
Core claim. The paper establishes that LLM-generated content in medical records systematically alters what downstream LLMs produce from those records, even when the AI content is neutral in tone. For note bloat, the effect is modest—reducing ROUGE-L by about 0.7 to 1.1 percentage points at moderate doses—but it is consistent across seven reader models and appears to be driven by the content of the AI notes, not just their wording or length. For diagnostic overcall, the propagation is substantial: unconfirmed differentials reappear in summaries up to 24.6% of the time for related targets, and clinician review confirms that 7 of 14 genuine overcalls propagated, 5 of which were rated likely to prompt unnecessary clinical work-up. Critically, the overcall propagation is invisible to standard document-level metrics, meaning current evaluation practices would miss this failure mode.
The premise it rests on. The diagnostic overcall experiment assumes that an injected differential diagnosis selected by ICD-9 code co-occurrence is a plausible simulation of a real AI-generated clinical overcall, but clinician review found that only 14 of 24 such injections were judged as genuine overcalls, meaning the measured propagation rates may not generalize to how LLMs handle real-world clinician-written overcalls.
If the paper is right (Pith's inferences, not the authors')
AI-assisted documentation tools should include monitoring for downstream effects on subsequent AI readers, not just on the immediate note quality.
Standard summarization metrics (ROUGE-L, BERTScore) are insufficient to detect targeted errors like propagated diagnostic overcalls; factuality or claim-level metrics may be needed.
The bloat effect, while modest, could compound over multiple admissions as AI notes accumulate, potentially causing larger shifts in patient summaries.
The variation in propagation rates across reader models suggests that model selection matters for safety-critical clinical summarization.
The paper calls for simulating recursive AI-in-the-loop documentation to understand long-term effects.
The study likely underestimates real-world risk because genuine clinician-written overcalls may be more subtle and harder for LLMs to resist, whereas the synthetic overcalls were often judged as plausible rather than genuine (10 of 24 not genuine).
The fact that propagation rates varied by model and by generator (Nemotron-written edits propagated less) suggests that the exact wording and context of the overcall matter; future work could systematically vary overcall phrasing to understand boundaries.
The finding that even neutral AI summaries ('bloat') degrade performance implies that any AI-generated text in the record—even apparently helpful summaries—may shift downstream outputs, raising safety concerns for ambient scribe tools that automatically insert AI notes.
The absence of detectable changes in standard metrics implies that current automated evaluation of clinical summarization may miss systematic errors; developing targeted factuality metrics for the clinical domain is a concrete next step.
Check this review
Pith stored no record of this review's passes and took no fingerprint of it. Reviews made by code from 13 Nov 2026 on carry both.
How often reviews like this one are right
Reviews like this one: written by deepseek-v4-flash, where what was read was not recorded.
How often objections from reviews like this one are right: not yet measured
Reviews by people
This review was written by a machine. No person has reviewed this paper on Pith yet. A scientist listed on Pith can review it for a fee, and their review is published here whatever it concludes.
The paper
Abstract
Large language models (LLMs) are increasingly used to process medical records for healthcare tasks such as clinical documentation. Because these tools also generate documentation, the relationship is now bidirectional: models both read from and write to the record. Understanding how LLMs behave when reading records that already contain LLM-authored content is therefore critical for their safe deployment. In this study, we examine how LLM-authored content in the medical record affects downstream LLMs that read the same record. We consider two types of LLM-induced artifacts: bloat, in which LLM-generated summaries accumulate in the record and change the length and provenance of its content over time; and distortion, in which LLMs subtly alter clinical findings rather than fabricating facts outright. As a case of distortion, we study diagnostic overcall (documenting an unconfirmed differential diagnosis in the record) and test whether it propagates to the reader LLM's output. Across seven reader models from four families, we find evidence of both effects. First, LLM-generated summary notes modestly but consistently degraded downstream hospital-course generation compared with copy-forward and templated text of matched length. Second, injected overcalls reappeared in downstream outputs at rates that varied by reader model, without detectable changes in standard quality metrics. These findings show the need to monitor AI-generated content in medical records and to account for it when those records are later processed by AI.
The paper's own sentences, arranged, kept beside the review and separate from it. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. No sentence in this record was written by a model.
abstract compiled · 2026-11-10
The authors' main claim, as the classifier picked it out 0.96
“These findings show the need to monitor AI-generated content in medical records and to account for it when those records are later processed by AI.”
How the main claim is stated: asserted 1.00
What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.24 · human participants 0.15 · controlled comparison 0.92 · randomized assignment 0.02 · states quantitative result 0.43 · compares with prior results 0.87 · mentions code or data availability 0.03
The abstract, sentence by sentence
This table labels the abstract only (arXiv listing abstract v1). The number is the probability the classifier gave the label.
| Sentence | Role | The authors' own work | States the main conclusion | Strength |
|---|---|---|---|---|
| Large language models (LLMs) are increasingly used to process medical records for healthcare tasks such as clinical documentation. | background 1.00 | 0.04 | 0.02 | asserted 0.99 |
| Because these tools also generate documentation, the relationship is now bidirectional: models both read from and write to the record. | background 0.98 | 0.05 | 0.02 | asserted 1.00 |
| Understanding how LLMs behave when reading records that already contain LLM-authored content is therefore critical for their safe deployment. | background 0.59 | 0.05 | 0.04 | asserted 0.98 |
| In this study, we examine how LLM-authored content in the medical record affects downstream LLMs that read the same record. | contribution 1.00 | 0.75 | 0.04 | asserted 0.83 |
| We consider two types of LLM-induced artifacts: bloat, in which LLM-generated summaries accumulate in the record and change the length and provenance of its content over time; and distortion, in which LLMs subtly alter clinical findings rather than fabricating facts outright. | contribution 0.75 | 0.22 | 0.03 | asserted 0.95 |
| As a case of distortion, we study diagnostic overcall (documenting an unconfirmed differential diagnosis in the record) and test whether it propagates to the reader LLM's output. | contribution 0.66 | 0.85 | 0.04 | asserted 0.84 |
| Across seven reader models from four families, we find evidence of both effects. | result 0.95 | 0.97 | 0.20 | asserted 0.96 |
| First, LLM-generated summary notes modestly but consistently degraded downstream hospital-course generation compared with copy-forward and templated text of matched length. | result 1.00 | 0.96 | 0.13 | asserted 1.00 |
| Second, injected overcalls reappeared in downstream outputs at rates that varied by reader model, without detectable changes in standard quality metrics. | result 1.00 | 0.96 | 0.14 | asserted 1.00 |
| These findings show the need to monitor AI-generated content in medical records and to account for it when those records are later processed by AI. | interpretation 0.86 | 0.31 | 0.91 | asserted 1.00 |
What kind of paper the classifier reports this is: empirical study 0.99 · evidence from observation or experiment 0.97
What was examined, and what was not
Sources read
- arXiv listing abstract v1
Not examined
- full text
- figures and tables
- references and citing sentences
- relations to other papers
Levels run
- P abstract
Not run
- S sections
- T body sentences
- C citations
- R cross-paper relations
How the labels were made
Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-11-10: 1 request, 7,571 input tokens.
Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. This record as JSON
Figures (3)
Figures are the authors', reproduced from the paper.
References (22)
- [1] Sina Alemohammad, Josue Casco-Rodriguez, Lorenzo Luzi, Ahmed Imtiaz Humayun, Hossein Babaei, Daniel LeJeune, Ali Siahkoohi, and Richard Baraniuk. Self-consuming generative models go MAD . In The Twelfth International Conference on Learning Representations, 2024. URL https://op... on Pith
- [2] Andrew M Bean, Rebecca Elizabeth Payne, Guy Parsons, Hannah Rose Kirk, Juan Ciro, Rafael Mosquera-Gómez, Sara Hincapié M, Aruna S Ekanayaka, Lionel Tarassenko, Luc Rocher, and Adam Mahdi. Reliability of LLMs as medical assistants for the general public: a randomized preregiste... on Pithdoi:10.1038/s41591-025-04074-y
- [3] Peter G Brodeur, Thomas A Buckley, Zahir Kanjee, Ethan Goh, Evelyn Bin Ling, Priyank Jain, Stephanie Cabral, Raja-Elie Abdulnour, Adrian D Haimovich, Jason A Freed, Andrew Olson, Daniel J Morgan, Jason Hom, Robert Gallo, Liam G McCoy, Haadi Mombini, Christopher Lucas, Misha Fo... on Pith
- [4] Jordan L Cahoon, Chloe Stanwyck, Asad Aali, Rachel Madding, Emma Sun, Yixing Jiang, Renumathy Dhanasekaran, and Emily Alsentzer. Clinical note bloat reduction for efficient LLM use. arXiv [cs.CY], 21 March 2026. URL http://arxiv.org/abs/2604.16364 on PithPith's reviewarXiv
- [5] Abhimanyu Dubey et al. The llama 3 herd of models. arXiv [cs.AI], 31 July 2024. URL http://arxiv.org/abs/2407.21783 on PithPith's reviewarXiv
- [6] Gemma Team . Gemma 4 technical report. arXiv [cs.CL], 2 July 2026. URL http://dx.doi.org/10.48550/arXiv.2607.02770 on PithPith's reviewarXivdoi:10.48550/arxiv.2607.02770
- [7] Alistair E W Johnson, Tom J Pollard, Lu Shen, Li-Wei H Lehman, Mengling Feng, Mohammad Ghassemi, Benjamin Moody, Peter Szolovits, Leo Anthony Celi, and Roger G Mark. MIMIC- III , a freely accessible critical care database. Scientific data, 3: 0 160035, May 2016. URL http://dx.... on Pithdoi:10.1038/sdata.2016.35
- [8] Woosuk Kwon, Zhuohan Li, Siyuan Zhuang, Ying Sheng, Lianmin Zheng, Cody Hao Yu, Joseph Gonzalez, Hao Zhang, and Ion Stoica. Efficient memory management for large language model serving with PagedAttention . In Proceedings of the 29th Symposium on Operating Systems Principles, ... on Pithdoi:10.1145/3600006.3613165
- [9] Philippe Laban, Hiroaki Hayashi, Yingbo Zhou, and Jennifer Neville. LLMs get lost in multi-turn conversation. In The Fourteenth International Conference on Learning Representations, 2026. URL https://openreview.net/forum?id=VKGTGGcwl6 on Pith
- [10] Shuyue Stella Li, Vidhisha Balachandran, Shangbin Feng, Jonathan S Ilgen, Emma Pierson, Pang Wei Koh, and Yulia Tsvetkov. MediQ : Question-asking LLMs and a benchmark for reliable interactive clinical reasoning. In The Thirty-eighth Annual Conference on Neural Information Proc... on Pith
- [11] Jinghui Liu, Daniel Capurro, Anthony Nguyen, and Karin Verspoor. ``note bloat'' impacts deep learning-based NLP models for clinical prediction tasks. Journal of biomedical informatics, 133: 0 104149, September 2022. URL http://dx.doi.org/10.1016/j.jbi.2022.104149 on Pithdoi:10.1016/j.jbi.2022.104149
- [12] Jinghui Liu, Sarvesh Soni, and Anthony Nguyen. Systematic evaluation of the quality of synthetic clinical notes rephrased by LLMs at million-note scale. In BioNLP 2026, pages 353--371, Stroudsburg, PA, USA, 2026. Association for Computational Linguistics. URL http://dx.doi.org... on Pithdoi:10.18653/v1/2026.bionlp-1.28
- [13] Nelson F Liu, Kevin Lin, John Hewitt, Ashwin Paranjape, Michele Bevilacqua, Fabio Petroni, and Percy Liang. Lost in the middle: How language models use long contexts. Transactions of the Association for Computational Linguistics, 12: 0 157--173, 23 February 2024. URL https://a... on Pith
- [14] Stephen P Ma, April S Liang, Shreya J Shah, Margaret Smith, Yejin Jeong, Anna Devon-Sand, Trevor Crowell, Clarissa Delahaie, Caroline Hsia, Steven Lin, Tait Shanafelt, Michael A Pfeffer, Christopher Sharp, and Patricia Garcia. Ambient artificial intelligence scribes: utilizati... on Pithdoi:10.1093/jamia/ocae304
- [15] Meta AI . The Llama 4 herd: The beginning of a new era of natively multimodal AI innovation. Blog post, April 2025. URL https://ai.meta.com/blog/llama-4-multimodal-intelligence/ on Pith
- [16] NVIDIA . NVIDIA Nemotron 3.5 Super and Lightning . Research page, October 2026. URL https://research.nvidia.com/labs/nemotron/Nemotron-3.5-Super-and-Lightning/ on Pith
- [17] Zihan Qiu, Zekun Wang, Xiao Li, Yanpeng Li, Yang Xu, Yixuan Wang, Huaqing Zhang, Rui Men, Bochao Mao, Chengruidong Zhang, Fan Zhou, Hao Luo, Haofeng Huang, Haoran Lian, Haoyan Huang, Hongqing Chen, Jianwei Zhang, Jing Xu, Junjie Wang, Langshi Chen, Liangyu Wang, Linlang Jiang,... on PithPith's reviewarXiv
- [18] Freda Shi, Xinyun Chen, Kanishka Misra, Nathan Scales, David Dohan, Ed H Chi, Nathanael Schärli, and Denny Zhou. Large language models can be easily distracted by irrelevant context. In International Conference on Machine Learning, pages 31210--31227. PMLR, 3 July 2023. URL ht... on Pith
- [19] Ilia Shumailov, Zakhar Shumaylov, Yiren Zhao, Nicolas Papernot, Ross Anderson, and Yarin Gal. AI models collapse when trained on recursively generated data. Nature, 631 0 (8022): 0 755--759, 24 July 2024. URL https://www.nature.com/articles/s41586-024-07566-y on Pith
- [20] Karan Singhal, Tao Tu, Juraj Gottweis, Rory Sayres, Ellery Wulczyn, Mohamed Amin, Le Hou, Kevin Clark, Stephen R Pfohl, Heather Cole-Lewis, Darlene Neal, Qazi Mamunur Rashid, Mike Schaekermann, Amy Wang, Dev Dash, Jonathan H Chen, Nigam H Shah, Sami Lachgar, Philip Andrew Mans... on Pith
show 2 more
- [21] Aaron A Tierney, Gregg Gayre, Brian Hoberman, Britt Mattern, Manuel Ballesca, Sarah B Wilson Hannay, Kate Castilla, Cindy S Lau, Patricia Kipnis, Vincent Liu, and Kristine Lee. Ambient artificial intelligence scribes: Learnings after 1 year and over 2.5 million uses. NEJM Cata... on Pithdoi:10.1056/cat.25.0040
- [22] Hongjian Zhou, Xinyu Zou, Jinge Wu, Sean Wu, Junchi Yu, Bradley Max Segal, Tobias Erich Niebuhr, Sara Amro, Michael Petrus, Sheikh Momin, Alexandra M Cardoso Pinto, Rachel Niesen, Laura Sophie Wegner, Dhruv Darji, Jung Moses Koo, Joshua Fieggen, Kapil Narain, Mingde Zeng, Lei ... on PithPith's reviewarXiv
Challenges and discussion
Disagree with the review, or know something it missed? Leave a comment, or challenge this review formally: a challenge becomes a permanent entry in this paper's record, and its decision is published here.
Come back by email
A short list of the week's newly reviewed papers. Nothing is sent until you confirm from your inbox, and every email has a link that stops it. No account.
No comments yet.
Sign in to comment