Pith.

Instrumentation and Methods for Astrophysics · arXiv:2611.17207 v1 · submitted 12 Nov 2026 · 24 references

Crest factor optimization of multi-tone signals generated for low-temperature sensor readout

L. H. Arnaldi

The paper says

“Microwave kinetic inductance detectors (MKID) are a growing technology of cryogenic detectors and have a great potential in radio-astronomy and cosmic microwave background (CMB) characterization.”

more of the abstract

A review of the general readout performance requirements for experiments requiring the multiplexing of large arrays ( 10.000 pixels) of such cryogenic detectors is presented. The focus is on the crest factor optimization process for proper excitation and readout of these large arrays of detectors. It is shown an algorithm to optimize the phase generation of the carriers to obtain a low crest factor, favoring the dynamic range usage of the electronic chain.

from the abstract

Pith says

Machine review · deepseek-v4-flash · 13 Nov 2026 · what was read was not recorded · not checked by a person

It can be wrong. Challenge this review or reply to it.

Holds up, with conditions. Newman phases are correctly applied to uniform equal-amplitude tones, but the paper's central claim for MKID arrays is unsupported because real resonances are not equally spaced. This line is wrong

4 major objections · 8 minor

How often objections from reviews like this one are right: not yet measured

Are you an author? What you can do.

Not checked: figures, code, what the 24 references say.

The paper says, at III.A.1, Eq. (13), Fig. 4, Fig. 5

The review did not quote this passage.

Pith says: Objection 1 of 4 · major

The entire crest factor analysis assumes equally spaced integer frequencies (Eq. 10, 13). The paper acknowledges in §III.A that reference [20] states equally spaced carriers are not the case for MKIDs. Despite this, all simulations and the contour comparison in Fig. 5 are performed under the equal-spacing assumption.

more of objection 1

No argument or simulation is provided to show that Newman phases preserve low crest factor when the carrier frequencies are non-uniform, as in a realistic MKID array. Therefore, the central quantitative claims (CF ~4.6 dB, sqrt(log N) scaling, and the resulting power-per-pixel advantage) are unverified for the advertised application. This is a load-bearing gap.

The paper says, at III.A.1, Eq. (14)

The review did not quote this passage.

Pith says: Objection 2 of 4 · major

Equation (14) gives the peak scaling for random amplitudes as 2.6 sqrt(log N) for N>=1000 and 2.4 sqrt(log N) for N<1000. The derivation of these prefactors is not explained; the text says 'simulations were carried out' but no details of the simulation (number of trials, amplitude distribution, phase distribution) are provided. Without this information, the result is not reproducible and its reliability is unclear.

The paper says, at IV, Conclusions

The review did not quote this passage.

Pith says: Objection 3 of 4 · major

The paper calls the Newman method 'optimal' (b127, b128). However, no proof of optimality is given, and the paper itself cites Boyd [18] who notes that standard optimization techniques do not help much and that Newman phases produce a crest factor only about 1.5 dB lower than Rudin-Shapiro phases. The claim of optimality is unsupported and should be toned down.

The paper says, at Fig. 5, Eq. (15)

The review did not quote this passage.

Pith says: Objection 4 of 4 · major

The contours in Fig. 5 are based on Eq. (15) which includes a factor s_max that 'sets the full scale width that the digitized multi-tone signal can achieve.' The relationship between s_max and the crest factor is not explicitly stated, and the calculation of the contours is not described in sufficient detail to be reproduced.

more of objection 4

The paper states that a 3 dB margin and up to 10 dB variation in Prms are considered, but the methodology for converting crest factor to required ADC noise density is not fully explained.

8 minor objections

The paper says, at Abstract

Pith says: minor objection 1 of 8

The abstract says '~10.000 pixels' but should be '~10,000 pixels' or '~10^4 pixels'.

The paper says, at I, Introduction

Pith says: minor objection 2 of 8

The phrase 'the main advantage of the working principle of these cryogenic detectors is that it is relatively easy to perform the frequency division multiplexing' is vague. Consider rephrasing for clarity.

show 6 more

The paper says, at II.A, Eq. (1)

Pith says: minor objection 3 of 8

The notation for the comb signal uses A_k, f_k, phi_k. It would be helpful to state explicitly that the amplitudes are assumed equal in the subsequent analysis, and that the Newman method is defined for equal amplitudes.

The paper says, at III.A.1, Fig. 4

Pith says: minor objection 4 of 8

The caption of Fig. 4 says 'the dotted line indicates the value of CF=4.6 dB, the theoretical minimum achievable with the Newman phases.' However, the paper does not derive this theoretical minimum; it is an empirical observation from simulations. The phrase 'theoretical minimum' is misleading.

The paper says, at III.A.1, Eq. (14)

Pith says: minor objection 5 of 8

The equation uses a piecewise definition with different prefactors for N>=1000 and N<1000. The justification for the threshold and the specific values is not given. Also, the units of ||u||_∞ are not dimensionless; since u is normalized to unit RMS, the peak is dimensionless, but the equation gives a numeric value without derivation.

The paper says, at Fig. 5

Pith says: minor objection 6 of 8

The two panels of Fig. 5 have different vertical axis ranges (left: -110 to -60 dBm, right: -90 to -20 dBm). This makes direct visual comparison difficult. Consider using the same scale or explaining the difference.

The paper says, at References

Pith says: minor objection 7 of 8

Reference [13] (McHugh et al.) is cited for the random-phase scaling and the contour method. It would be helpful to briefly summarize the relevant results from [13] to make the paper more self-contained.

The paper says, at General

Pith says: minor objection 8 of 8

The paper contains several grammatical errors and awkward phrasings (e.g., 'the main contribution be seen', 'it is shown an algorithm'). A thorough language edit is recommended.

What would settle it

Run a numerical experiment: generate N tones at frequencies f_k that are not equally spaced, e.g., drawn from a realistic MKID resonance distribution (random within the channel bandwidth, or a measured distribution) while keeping the same Newman phases theta_k = pi (k-1)^2/(2N) assigned by channel index. Compute the crest factor of the summed signal u(n) = sqrt(2/N) sum cos(2 pi f_k n + theta_k) over one period T for N = 100, 1000, and 10000. Compare the resulting CF (in dB) to the equal-spacing value of ~4.6 dB. If CF exceeds, say, 8 dB or grows like sqrt(N), the method does not transfer to non-uniform arrays. Repeat with the random amplitudes used in Fig. 4. The test is directly checkable with a short simulation script and would settle whether the paper's central claim holds for its stated application.

from the skeptic's reading

How the review went

4 readings by deepseek-v4-flash · 13 Nov 2026

  1. Reader holds up, with conditions confidence moderate
  2. Skeptic agrees 17 s · 11,309 tokens read, 2,570 written
  3. Editor wrote the verdict above 7 s · 12,393 tokens read, 533 written
  4. Referee major revision: 4 major objections, 8 minor 13 s · 11,802 tokens read, 1,375 written

Not run on this paper: the simulated authors' defence.

Pith did not check this review's objections against the paper.

The review in full

The review in brief, machine-written

Hi,

This paper applies Newman's quadratic phase formula (theta_k = pi (k-1)2/(2N)) to multi-tone readout signals for MKID arrays and reports crest factors near 4.6 dB for uniform equal-amplitude tones. The review of MKID readout electronics is competent, and the reproduction of known CF values (5.635 dB for N=32, 4.628 dB for N=1024) is correct. The paper also includes a random-amplitude simulation (Eq. 14, Fig. 4) showing that CF degrades to ~10.5 dB when amplitudes vary, which is a useful practical note.

The soft spot is load-bearing. The entire low-CF construction assumes equally spaced integer-frequency tones (Eqs. 10, 13). The paper itself acknowledges that MKID resonances are not equally spaced (citing [20]), yet all simulations and the contour comparison in Fig. 5 are performed under the equal-spacing assumption. There is no argument or simulation showing that Newman phases preserve cancellation for non-uniform channel spacing. Without that, the claimed ~4.6 dB CF, sqrt(log N) scaling, and power-per-pixel advantages do not transfer to realistic MKID arrays. The paper also calls the method "optimal" without a proof of optimality, and the simulations behind Eq. (14) and Fig. 5 are not reproducible from the text.

Who this is for: engineers already familiar with MKID readout who want a clear exposition of Newman phases applied to uniform tones. The review sections are useful for newcomers. But the central application claim is unverified.

Recommendation: I would not desk-reject this, but I would send it back for major revision. The authors need to either (a) demonstrate that the CF remains low for non-uniform channel spacing (simulation with realistic MKID frequencies), or (b) clearly delimit the scope to uniform tones and remove the unsubstantiated claims about MKID arrays. The paper is not a new derivation, but it is a competent application note that could be valuable if the scope is honestly bounded.

The strongest objection

The paper's central quantitative claims—crest factor near 4.6 dB for large N, peak growth like sqrt(log N), and the resulting increase in per-pixel readout power (Fig. 5, Eq. 15)—rest on the behavior of u_new_N(n) in Eqs. (10) and (13), which assumes N tones at consecutive integer frequencies k+N_0 with equal amplitudes. The paper itself acknowledges that MKID resonance frequencies are not equally spaced: it notes that reference [20] states 'the lowest crest factor is obtained by applying carriers equally spaced in frequency, which would not be the case for MKIDs.' Despite this, all simulations (Fig. 4, Eq. 14) and the contour comparison in Fig. 5 are performed under the equal-spacing assumption. The Newman phase formula theta_k = pi (k-1)^2/(2N) is derived for this specific equally spaced, integer-frequency structure; there is no argument or simulation showing that the quadratic phase progression preserves the cancellation property when the carrier frequencies are arbitrary real values within the Nyquist band, as they are for a realistic MKID array. The paper's random-amplitude simulation (Fig. 4) still uses the same equally spaced grid, so it does not probe the non-uniform-frequency case. Without evidence that the crest factor remains low for non-uniform channel spacing, the claimed advantage in readout power per pixel and the sqrt(log N) scaling do not transfer to the actual MKID application. The conclusion that the Newman algorithm is 'optimal' is also unsupported by a proof, but the more consequential gap is the transferability under non-uniform spacing.

The reader's weakest_assumption pinpointed the equal-spacing requirement, and my independent reading agrees that this is the most load-bearing condition. The paper explicitly acknowledges that MKID arrays are not equally spaced but proceeds to draw quantitative conclusions (power per pixel, ADC noise floor requirements, sqrt(log N) scaling) from simulations that assume equal spacing. This is not a matter of disagreeing with an external consensus; it is an internal gap between the method's proven domain and the application's stated conditions. The core Newman-phase result for the uniform case is real and correctly cited, so the paper is not rejected outright, but the transferability claim must be demonstrated. No other concern is as consequential: the optimality claim is weaker (calls for a proof, but does not undermine the reported numbers), the comparison against the conservative sqrt(N) model in Fig. 5 is a fair choice as a baseline, and the lack of full reproducibility is a practical issue rather than a logical flaw. The concrete test I propose directly removes the ambiguity by simulating the realistic non-uniform case.

The referee's report

If the claims hold, the method could improve dynamic range utilization in MKID readout, potentially enabling larger arrays. However, the significance is limited because the central assumption of equally spaced tones does not match real MKID arrays, and the paper does not address this gap.

Pith's reading of the paper (a machine's summary, not the authors')

Cold microwave detectors are usually read out by sending many different radio-frequency carriers down one cable, one carrier per detector. If all carriers are generated with the same phase, they add up into a large peak, forcing the electronics to keep the average signal low and wasting dynamic range. The ratio of peak to average is the crest factor. Randomizing the phases spreads the peaks and lowers the crest factor, but for very large arrays the peak still grows with the number of carriers.

Newman phases are a classical 1965 construction: each carrier is given a phase that is a quadratic function of its frequency index. The paper calculates the crest factor for arrays up to 16,384 uniformly spaced tones and reports about 4.6 dB, compared with roughly 18 dB for in-phase tones and about 7.7 dB for 32 random-phase tones. It also simulates what happens when carrier powers are varied, as is common in real detector readout, and finds the crest factor rises to about 10.5 dB and grows only logarithmically with array size. These numbers are compared with an earlier random-phase readout model, showing a higher allowed power per detector and a lower required ADC noise floor.

The main caveat is that Newman phases are designed for equally spaced, equal-amplitude tones. Real detector resonances are not uniformly spaced, and the paper does not test the formula on a realistic channel list. The paper also calls the phase choice optimal without proving it; it is a known low-crest-factor construction, not a proven optimum.

Core claim. The load-bearing assertion is that assigning Newman phases theta_k = pi (k-1)^2 / (2N) to N equally spaced readout tones keeps the crest factor near 4.6 dB for arrays up to thousands of tones, versus about 18 dB for zero phases and a peak that grows like sqrt(2N) for in-phase tones. The paper applies this to MKID readout and claims it changes the effective power gain scaling from sqrt(N) (random phases, reference [13]) to sqrt(log N), allowing more readout power per pixel and a lower required ADC noise floor. If true, large ~10,000 pixel arrays can use converter dynamic range more efficiently.

The premise it rests on. The entire low-crest-factor construction assumes the carrier frequencies form a consecutive, equally spaced set of integers, as in u(n) = sqrt(2/N) sum cos(k n + theta_k) in Eqs. (10) and (13), with equal amplitudes. Real MKID resonators are not equally spaced; the paper itself notes that reference [20] shows equally spaced carriers are not the case for MKIDs because resonance positions depend on several factors. Newman's quadratic phases have no demonstrated cancellation property for an arbitrary nonuniform channel list, so the reported crest factor, noise-floor contours, and power savings do not transfer to a realistic MKID array without additional work.

Check this review

Pith stored no record of this review's passes and took no fingerprint of it. Reviews made by code from 13 Nov 2026 on carry both.

How often reviews like this one are right

Reviews like this one: written by deepseek-v4-flash, where what was read was not recorded.

How often objections from reviews like this one are right: not yet measured

Every value above, in the review's public record (JSON)

Reviews by people

This review was written by a machine. No person has reviewed this paper on Pith yet. A scientist listed on Pith can review it for a fee, and their review is published here whatever it concludes.

Request a human review

How Pith checks papers · The full audit of this paper

The paper

Abstract

Microwave kinetic inductance detectors (MKID) are a growing technology of cryogenic detectors and have a great potential in radio-astronomy and cosmic microwave background (CMB) characterization. A review of the general readout performance requirements for experiments requiring the multiplexing of large arrays ( 10.000 pixels) of such cryogenic detectors is presented. The focus is on the crest factor optimization process for proper excitation and readout of these large arrays of detectors. It is shown an algorithm to optimize the phase generation of the carriers to obtain a low crest factor, favoring the dynamic range usage of the electronic chain.

The paper's own sentences, arranged, kept beside the review and separate from it. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. No sentence in this record was written by a model.

abstract compiled · 2026-11-14

The authors' main claim, as the classifier picked it out 1.00

“It is shown an algorithm to optimize the phase generation of the carriers to obtain a low crest factor, favoring the dynamic range usage of the electronic chain.”

How the main claim is stated: asserted 1.00

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.07 · human participants 0.02 · controlled comparison 0.03 · randomized assignment 0.01 · states quantitative result 0.23 · compares with prior results 0.07 · mentions code or data availability 0.03

The abstract, sentence by sentence

This table labels the abstract only (arXiv listing abstract v1). The number is the probability the classifier gave the label.

SentenceRoleThe authors' own workStates the main conclusionStrength
Microwave kinetic inductance detectors (MKID) are a growing technology of cryogenic detectors and have a great potential in radio-astronomy and cosmic microwave background (CMB) characterization. background 1.00 0.04 0.03 asserted 0.95
A review of the general readout performance requirements for experiments requiring the multiplexing of large arrays (~10.000 pixels) of such cryogenic detectors is presented. contribution 0.51 0.44 0.04 asserted 0.91
The focus is on the crest factor optimization process for proper excitation and readout of these large arrays of detectors. contribution 0.72 0.26 0.12 asserted 0.79
It is shown an algorithm to optimize the phase generation of the carriers to obtain a low crest factor, favoring the dynamic range usage of the electronic chain. method 0.50 0.87 0.62 asserted 1.00

What kind of paper the classifier reports this is: method or tool 0.97 · evidence from simulation or computation 0.45

What was examined, and what was not

Sources read

  • arXiv listing abstract v1

Not examined

  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers

Levels run

  • P abstract

Not run

  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

How the labels were made

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-11-14: 1 request, 3,638 input tokens.

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. This record as JSON

Figures (5)
Figure 1 of the paper
Figure 1. Block diagram of a proposed system for the readout of superconducting detectors working at microwave frequencies. For clarity, various amplifiers
Figure 2 of the paper
Figure 2. Signals, u(n), with different crest factors. Both graphs show the FDM signal obtained as the sum of 32 tones (black). Tones have constant amplitudes and phases θk = 0 (top) and constant amplitudes and random phases (bottom). The crest factor is 18.090 dB for the constant case and 7.713 dB for the random case. In the literature there are few articles that address the problem, for example [20] investigates how to obtain a low crest factor for the excitation of TES detector arrays at low carrier frequencies. The authors mention that the lowest crest factor is obtained by applying…
Figure 4 of the paper
Figure 4. Evolution of the crest factor with Newman’s phases for each
Figure 5 of the paper
Figure 5. Required ADC noise density floor in dBc/Hz as a function of number of resonators being read versus readout power per resonator for an amplifier

Showing 4 of the paper's 5 figures. Figures are the authors', reproduced from the paper.

References (24)
  1. [20] M. A. Lindeman, R. Hijmering, P. Khosropanah, P. A. De Korte, R. Den Hartog, L. Gottardi, J. Van Der Kuur, and H. Hoevers, “Carrier phase optimization for frequency division multiplexing of low temperature detectors,”J. Low Temp. Phys., vol. 167, no. 5-6, pp. 701–706, 2012 on Pith
  2. [18] S. Boyd, “Multitone Signals with Low Crest Factor,”IEEE Trans. Circuits Syst., vol. 33, no. 10, pp. 1018–1022, 1986 on Pith
  3. [1] E. Battistelliet al., “QUBIC: The QU bolometric interferometer for cosmology,”Astropart. Phys., vol. 34, no. 9, pp. 705–716, 2011 on Pith
  4. [2] M. H. Abitlbolet al., “CMB-S4 Technology Book, First Edition,” on Pith
  5. [3] P. K. Day, H. G. LeDuc, B. A. Mazin, A. Vayonakis, and J. Zmuidzinas, “A broadband superconducting detector suitable for use in large arrays.” Nature, vol. 425, no. 6960, pp. 817–21, oct 2003 on Pith
  6. [4] B. A. Mazin, “Microwave kinetic inductance detectors. PhD thesis,” California Institute of Technology, 2004 on Pith
  7. [5] J. Gao, “The physics of superconducting microwave resonators. PhD thesis,”California Institute of Technology, 2008 on Pith
  8. [6] M. Piatet al., “Qubic iv: Performance of tes bolometers and readout electronics,”Journal of Cosmology and Astroparticle Physics, vol. 2022, no. 4, 2022 on Pith
  9. [7] K. D. Irwin and K. W. Lehnert, “Microwave SQUID multiplexer,”Appl. Phys. Lett., vol. 85, no. 11, pp. 2107–2109, 2004 on Pith
  10. [8] S. Kempf, M. Wegner, L. Deeg, A. Fleischmann, L. Gastaldo, F. Her- rmann, D. Richter, and C. Enss, “Design, fabrication and characterization of a 64 pixel metallic magnetic calorimeter array with integrated, on- chip microwave SQUID multiplexer,”Supercond. Sci. Technol., vol. ... on Pith
  11. [9] A. B. Walter, N. Fruitwala, S. Steiger, J. I. Bailey, N. Zobrist, N. Swim- mer, I. Lipartito, J. P. Smith, S. R. Meeker, C. Bockstiegel, G. Coiffard, R. Dodkins, P. Szypryt, K. K. Davis, M. Daal, B. Bumble, G. Collura, O. Guyon, J. Lozi, S. Vievard, N. Jovanovic, F. Martinache... on Pith
  12. [10] D. C. Araujo, P. A. R. Ade, J. R. Bond, K. J. Bradford, D. Chapman, G. Che, P. K. Day, J. Didier, S. Doyle, H. K. Eriksen, D. Flanigan, C. E. Groppi, S. N. Hillbrand, B. R. Johnson, G. Jones, M. Limon, A. D. Miller, P. Mauskopf, H. McCarrick, T. Mroczkowski, B. Reichborn- Kjen... on Pith
  13. [11] N. Zobrist, N. Klimovich, B. Ho Eom, G. Coiffard, M. Daal, N. Swim- mer, and B. A. Mazin, “Improving the dynamic range of single photon counting kinetic inductance detectors,”SPIE Astron. Telesc. + Instrum., 2021 on Pith
  14. [12] G. Ulbricht, M. De Lucia, and E. Baldwin, “Applications for Microwave Kinetic Induction Detectors in Advanced Instrumentation,”Applied Sciences (Switzerland), 2021 on Pith
  15. [13] S. McHugh, B. a. Mazin, B. Serfass, S. Meeker, K. O’Brien, R. Duan, R. Raffanti, and D. Werthimer, “A readout for large arrays of microwave kinetic inductance detectors,”Rev. Sci. Instrum., vol. 83, no. 4, p. 044702, apr 2012 on Pith
  16. [14] O. Noroozian, J. Gao, J. Zmuidzinas, H. G. LeDuc, B. a. Mazin, B. Young, B. Cabrera, and A. Miller, “Two-level system noise reduction for Microwave Kinetic Inductance Detectors,” inJet Propuls., 2009, pp. 148–151 on Pith
  17. [15] N. G. Czakon, A. Vayonakis, J. Schlaerth, M. I. Hollister, S. Golwala, P. K. Day, J. S. Gao, J. Glenn, H. LeDuc, P. R. Maloney, B. Mazin, O. Noroozian, H. T. Nguyen, J. Sayers, J. E. Vaillancourt, and J. Zmuidz- inas, “Microwave kinetic inductance detector (MKID) camera testin... on Pith
  18. [16] J. Baselmans, “Kinetic Inductance Detectors,”Low Temp Phys, vol. 167, no. January, pp. 292–304, 2012 on Pith
  19. [17] B. A. Mazin, B. Young, B. Cabrera, and A. Miller, “Microwave Kinetic Inductance Detectors: The First Decade,” inAIP Conf. Proc., vol. 1185, no. 2009, sep 2009, pp. 135–142 on Pith
  20. [19] A. Gersho, B. Gopinath, and A. M. Odlyzko, “Coefficient Inaccuracy in Transversal Filtering,”Bell Syst. Tech. J., vol. 58, no. 10, pp. 2301–2316, 1979 on Pith
show 4 more
  1. [21] W. Rudin, “Some Theorems on Fourier Coefficients,”Proc. Am. Math. Soc., vol. 10, no. 6, p. 855, 1959 on Pith
  2. [22] H. Shapiro, “Extremal problems for polynomials and power series,”MIT, 1951 on Pith
  3. [23] D. J. Newman, “An L 1 Extremal Problem for Polynomials,”Proc. Am. Math. Soc., vol. 16, no. 6, p. 1287, 1965 on Pith
  4. [2017] [Online]. Available: http://arxiv.org/abs/1706.02464 on PithPith's reviewarXiv

Challenges and discussion

Disagree with the review, or know something it missed? Leave a comment, or challenge this review formally: a challenge becomes a permanent entry in this paper's record, and its decision is published here.

No comments yet.

Sign in to comment